Experimental Evaluation of a Novel Percutaneous Transseptal Catheter-Based Mitral Valve Replacement Technology

被引:1
|
作者
Vahl, Torsten P. [1 ,2 ]
Grogan, Aaron [3 ]
Cheng, Yanping [2 ]
Yi, Genghua [2 ]
von Oepen, Randolf [4 ]
Khalique, Omar K. [1 ]
Wallace, Daniel T. [3 ]
Modine, Thomas [5 ]
Granada, Juan F. [2 ]
机构
[1] Columbia Univ, Dept Med, Div Cardiol, New York Presbyterian Hosp,Irving Med Ctr, New York, NY USA
[2] CRF Skirball Ctr Innovat, Orangeburg, NY USA
[3] Cephea Valve Technol Inc, Santa Cruz, CA USA
[4] Abbott Vasc, Santa Clara, CA USA
[5] CHRU Lille, Hop Cardiol, Serv Chirurg Cardiovasc, Lille, France
关键词
echocardiography; hemodynamics; mitral valve; sheep; thrombosis; MYOCARDIAL INJURY; IMPLANTATION; PREDICTORS; INSIGHTS;
D O I
10.1161/CIRCINTERVENTIONS.119.008002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Transcatheter mitral valve replacement is a novel therapeutic approach aiming to treat patients with severe mitral regurgitation. This study aimed to evaluate the biological and technical performance of a novel transseptal transcatheter mitral valve replacement system (Cephea Valve Technologies, Santa Cruz, CA) in a preclinical model. Methods: Biological performance and healing response were evaluated following open-heart surgical implantation procedures in 10 sheep utilizing an antegrade transatrial access. Valve performance was assessed with fluoroscopy, echocardiography, and histology at 30 (n=2), 60 (n=3), and 90 days (n=5). Feasibility of transseptal valve delivery and performance was tested acutely in 10 pigs. Results: In the chronic studies, all animals survived without problems until completion of the study. The hemodynamics of the study valves were excellent with low rates of paravalvular leak. There was no left ventricular outflow tract obstruction. Pathological evaluation showed excellent position and condition of the mitral implants without evidence for thrombosis, endocarditis, or excessive calcification. Subsequently, mitral valves were implanted in 10 pigs using a dedicated transseptal delivery system. The implants remained in stable position with excellent hemodynamic profile. Correct valve position and function was confirmed by echocardiography and autopsy. Conclusions: The transseptal delivery of the Cephea transcatheter mitral valve replacement system in an experimental model was feasible and safe. The chronic studies demonstrated a favorable healing response. Further human studies are needed to evaluate the performance of this novel valve system in patients with severe mitral regurgitation.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Preoperative planning using virtual reality for percutaneous transseptal valve-in-valve transcatheter mitral valve replacement: a case report
    Castellanos, Jorge M.
    Barbery, Daniela
    Yefimov, Alex
    Dang, Phuong N.
    [J]. EUROPEAN HEART JOURNAL-CASE REPORTS, 2022, 6 (10)
  • [32] Current Treatment Options for Catheter-Based Pulmonary Valve Replacement in Children
    Zablah J.E.
    Morgan G.J.
    [J]. Current Treatment Options in Pediatrics, 2020, 6 (4) : 274 - 282
  • [33] Transcatheter transseptal treatment of patients with severe mitral regurgitation using an atrial fixation mitral valve replacement technology
    Ninios, Vlasis
    Ninios, Ilias
    Ranard, Lauren S.
    Vahl, Torsten P.
    Wrobel, Krzysztof
    [J]. CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2024, 58 : 25 - 30
  • [34] Echocardiographic Evaluation of Iatrogenic Atrial Septal Defect After Catheter-Based Mitral Valve Clip Insertion
    Saitoh, Takeji
    Izumo, Masaki
    Furugen, Azusa
    Tanaka, Jun
    Miyata-Fukuoka, Yoko
    Gurudevan, Swaminatha V.
    Tolstrup, Kirsten
    Siegel, Robert J.
    Kar, Saibal
    Shiota, Takahiro
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2012, 109 (12): : 1787 - 1791
  • [35] Catheter-based management of aortic valve regurgitation in experimental cardiology
    Sochman, J.
    Peregrin, J. H.
    [J]. PHYSIOLOGICAL RESEARCH, 2008, 57 (03) : 321 - 326
  • [36] Evaluating Catheter-Based Mitral Valve Therapies Lessons Learned and Future Directions
    Anyanwu, Anelechi C.
    Adams, David H.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (25) : 2855 - 2859
  • [37] VALUE OF THE SUPERIOR TRANSSEPTAL APPROACH IN MITRAL-VALVE REPLACEMENT
    FRAPIER, JM
    CARABASSE, D
    SEGUIN, JR
    PICARD, E
    MEUNIER, JP
    CHAPTAL, PA
    [J]. ANNALES DE CHIRURGIE, 1994, 48 (09): : 809 - 813
  • [38] Transseptal transcatheter mitral valve implantation versus redo surgical mitral valve replacement for degenerated mitral bioprostheses
    Fuchs, A.
    Lung, B.
    Nguyen, C.
    Carrasco, J. L.
    Cimadevilla, C.
    Kernels, C.
    Eugene, M.
    Ghodhbane, W.
    Ducrocq, G.
    Brochet, E.
    Provenchere, S.
    Vahanian, A.
    Himbert, D.
    Urena-Alcazar, M.
    [J]. EUROPEAN HEART JOURNAL, 2020, 41 : 2633 - 2633
  • [39] A LOW PROFILE TRANSSEPTAL FULLY ATRIAL SCAFFOLD FOR TRANS-CATHETER MITRAL VALVE REPLACEMENT: A FEASIBILITY STUDY
    Tavakoli, Vahid
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 1094 - 1094
  • [40] A novel image fusion technique to improve transseptal puncture during percutaneous mitral valve repair
    Meijerink, F.
    Wolsink, I
    Van Mourik, M. S.
    Planken, R. N.
    Boekholdt, S. M.
    Bouma, B. J.
    Baan, J.
    [J]. EUROPEAN HEART JOURNAL, 2020, 41 : 1944 - 1944