Capillary concentrators for synchrotron radiation beamlines

被引:2
|
作者
Heald, SM
Brewe, DL
Kim, KH
Brown, FC
Barg, B
Stern, EA
机构
关键词
tapered capillary; x-ray imaging; micro-XAFS; x-ray microprobe; synchrotron radiation; x-ray optics;
D O I
10.1117/12.259883
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Capillary concentrators condense x-rays by multiple reflections down a gradually tapering capillary. They can provide sub-micron beam spots, and are promising candidates for use in the next generation x-ray microprobe beamlines. The weak energy dependence of their properties make them especially useful for energy scanning applications such as micro-XAFS. This paper examines the potential performance of capillary optics for an x-ray microprobe, as well as some practical issues such as fabrication and alignment. Best performance at third generation sources requires long capillaries, and we have been using fiber optics techniques to fabricate capillaries up to one meter in length. The performance of shorter (less than about 0.5 m) capillaries has often been found to agree well with theoretical calculations, indicating the inner surface is a high quality x-ray reflector. These capillaries have been tested at the NSLS for imaging and micro-XAFS down to 2.6 mu m resolution with excellent results. On an unfocused bend magnet line flux density approaching 10(6) ph/sec/mu m(2) has been achieved. While nearly optimum profiles have been achieved for longer capillaries, the results have been disappointing, and alignment problems are suspected. The dramatic improvement in performance possible at third generation synchrotrons such as the APS is discussed along with improvements possible by using the capillaries in conjunction with coupling optics.
引用
收藏
页码:36 / 47
页数:12
相关论文
共 50 条
  • [41] SYNCHROTRON BEAMLINES OPEN AS PLANS ARE LAID FOR REPAIRS
    BIGGIN, S
    NATURE, 1992, 360 (6399) : 3 - 3
  • [42] Instrumentation and Experimental Developments for the Beamlines at the Synchrotron SOLEIL
    Prigent, P.
    Bac, S.
    Blanchandin, S.
    Cauchon, G.
    David, G.
    Varela, P. Fernandez
    Kubsky, S.
    Picca, F.
    SRI 2009: THE 10TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION, 2010, 1234 : 379 - 382
  • [43] An Accurate Optical Design Method for Synchrotron Radiation Beamlines with Wave-front Aberration theory
    Yu, Xiaojiang
    Diao, Caozheng
    Breese, Mark B. H.
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI2015), 2016, 1741
  • [44] Chemical Crystallography at the Australian Synchrotron MX Beamlines
    Price, J.
    Aragao, D.
    Cowieson, N.
    Panjikar, S.
    Riboldi-Tunnicliffe, A.
    Williamson, R.
    Caradoc-Davies, T.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2014, 70 : C1751 - C1751
  • [45] SiC free-standing membrane for X-ray intensity monitoring in synchrotron radiation beamlines
    Trovato, Gabriele
    De Napoli, Marzio
    Gollwitzer, Christian
    Finizio, Simone
    Krumrey, Michael
    La Via, Francesco
    Lanzano, Luca
    Milluzzo, Giuliana
    Moscato, Samuele
    Mueller, Matthias
    Romano, Francesco
    Sanchez, Dario Ferreira
    Camarda, Massimo
    JOURNAL OF SYNCHROTRON RADIATION, 2025, 32 : 118 - 124
  • [46] Light flux density threshold at which protein denaturation is induced by synchrotron radiation circular dichroism beamlines
    Miles, A. J.
    Janes, Robert W.
    Brown, A.
    Clarke, D. T.
    Sutherland, J. C.
    Tao, Y.
    Wallace, B. A.
    Hoffmann, S. V.
    JOURNAL OF SYNCHROTRON RADIATION, 2008, 15 (04) : 420 - 422
  • [47] Application of partially coherent wavefront propagation calculations for design of coherence-preserving synchrotron radiation beamlines
    Chubar, Oleg
    Chu, Yong S.
    Kaznatcheev, Konstantine
    Yan, Hanfei
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 649 (01): : 118 - 122
  • [48] AREA DETECTORS ON BEAMLINES - ABSTRACT INCORPORATING LARGE AREA DETECTORS INTO SYNCHROTRON BEAMLINES: THE CHESS EXPERIENCE
    Szebenyi, D.
    Cook, M.
    Deacon, A.
    Ealick, S.
    Heaton, C.
    Kriksunov, I.
    LaIuppa, J.
    Miller, W.
    Thiel, D.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 1999, 55 : 239 - 239
  • [49] In crystallo optical spectroscopy at synchrotron beamlines - where we are at?
    Dworkowski, Florian
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2015, 71 : S141 - S141
  • [50] PROPERTIES OF FOCUSING GLASS-CAPILLARY CONCENTRATORS OF SOFT-X-RAY RADIATION
    KANTSYREV, VL
    INOZEMTSEV, AP
    PETRUCHIN, OG
    TOLSTICHIN, OI
    SHLYAPTSEVA, AS
    KVANTOVAYA ELEKTRONIKA, 1995, 22 (01): : 84 - 86