Design and evaluation of a condensation particle counter with high performance for single-particle counting

被引:4
|
作者
Wang, Wenyu [1 ,2 ]
Zhao, Xin [2 ]
Zhang, Jiaoshi [2 ,3 ]
Yang, Yixin [1 ,2 ]
Yu, Tongzhu [2 ,3 ]
Bian, Jiejie [1 ,2 ]
Gui, Huaqiao [2 ,3 ]
Liu, Jianguo [1 ,2 ,3 ]
机构
[1] Univ Sci & Technol China, Coll Environm Sci & Optoelect Technol, Hefei, Anhui, Peoples R China
[2] Chinese Acad Sci, Anhui Inst Opt & Fine Mech, Key Lab Environm Opt & Technol, Hefei, Anhui, Peoples R China
[3] Chinese Acad Sci, Inst Urban Environm, Ctr Excellence Reg Atmospher Environm, Xiamen, Fujian, Peoples R China
关键词
Condensation particle counter; detection efficiency; particle electronic pulse; single-particle counting; EFFICIENCY; FLOW;
D O I
10.1080/10739149.2019.1687516
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A full-flow butanol-based condensation particle counter (CPC) with a concentration range from 0 to 2 x 10(5) particles/cm(3) was developed to measure nanoparticles down to 4.5 nm. Good single-particle counting performance was achieved by developing a high-speed optical particle detection module. The pulse width of single particle was approximately 1.2 mu s at a flow rate of 0.3 L/min. By establishing a heat and mass transfer model using the COMSOL simulation software, the effects of temperature and aerosol sampling flow on the condensation growth of nanoparticles were studied. The performance of developed condensation particle counter was evaluated through a series of experiments to determine the coincidence probability, concentration range, and detection efficiency (cutoff diameter). At concentrations of 1.5 x 10(4) particles/cm(3) and 2 x 10(5) particles/cm(3), the coincidence probabilities of the developed condensation particle counter were 9.5% and 55%, respectively. A 99.9% (R-2) statistical correlation was obtained between the pulse-time corrected concentration of the developed condensation particle counter and the standard reference concentration. Finally, the experimental results showed that the developed condensation particle counter cutoff diameter, at which the detection efficiency was 50%, for sucrose aerosol particles was 4.5 nm.
引用
收藏
页码:212 / 229
页数:18
相关论文
共 50 条
  • [11] SINGLE-PARTICLE COUNTING OF HEAVY-IONS WITH A CHANNELTRON DETECTOR
    FRICKE, J
    MULLER, A
    SALZBORN, E
    NUCLEAR INSTRUMENTS & METHODS, 1980, 175 (2-3): : 379 - 384
  • [12] RESPONSE CHARACTERISTICS OF THE MULTIPLE-RATIO SINGLE-PARTICLE COUNTER
    HIRLEMAN, ED
    MOON, HK
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1982, 87 (01) : 124 - 139
  • [13] Evaluation of the performance of classification algorithms for XFEL single-particle imaging data
    Shi, Yingchen
    Yin, Ke
    Tai, Xuecheng
    DeMirci, Hasan
    Hosseinizadeh, Ahmad
    Hogue, Brenda G.
    Li, Haoyuan
    Ourmazd, Abbas
    Schwander, Peter
    Vartanyants, Ivan A.
    Yoon, Chun Hong
    Aquila, Andrew
    Liu, Haiguang
    IUCRJ, 2019, 6 : 331 - 340
  • [14] Design and test of a high-speed single-particle beam monitor
    Pernegger, H
    Frais-Kölbl, H
    Griesmayer, E
    Kagan, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 535 (1-2): : 108 - 114
  • [15] EVALUATION OF SANBORN-FROMMER PARTICLE COUNTER FOR COUNTING LEUKOCYTES
    HOLTHUSEN, G
    KIPP, MA
    WENZEL, FJ
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1963, 39 (05) : 541 - &
  • [16] EVALUATION OF AN ELECTRONIC PARTICLE COUNTER FOR THE COUNTING OF WHITE BLOOD CELLS
    RICHAR, WJ
    BREAKELL, ES
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1959, 31 (05) : 384 - 393
  • [17] SINGLE-PARTICLE STATES
    不详
    NATURE, 1973, 245 (5420) : 74 - 74
  • [18] Single-particle analysis
    Ludtke, S
    Chiu, W
    JOURNAL OF STRUCTURAL BIOLOGY, 2001, 133 (2-3) : 89 - 89
  • [19] SINGLE-PARTICLE MOTION
    TALMAN, R
    FRONTIERS OF PARTICLE BEAMS : OBSERVATION, DIAGNOSIS AND CORRECTION, 1989, 343 : 4 - 45
  • [20] Single-particle imaging
    Sayre, David
    Evolving Methods for Macromolecular Crystallography: THE STRUCTURAL PATH TO THE UNDERSTANDING OF THE MECHANISM OF ACTION OF CBRN AGENTS, 2007, 245 : 181 - 191