Clinical application value of 3.0T MR diffusion tensor imaging in grade diagnosis of gliomas

被引:14
|
作者
Shan, Wei [1 ]
Wang, Xing-Long [1 ]
机构
[1] First Peoples Hosp Shangqiu, Med Image Ctr, 292 Kaixuan South Rd, Shangqiu 476100, Henan, Peoples R China
关键词
glioma; MR dynamic contrast-enhanced scan; diffusion tensor imaging; pathology; RESONANCE; TRACKING; TUMORS; BRAIN;
D O I
10.3892/ol.2017.6378
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The clinical value of MR diffusion tensor imaging (DTI) in grade diagnosis of gliomas was investigated. A total of 31 patients with glioma were administered 3.0T MR convention and DTI examination, with quantitative measurement of anisotropy coefficient fractional anisotropy (FA) and apparent dispersion coefficient (ADC) value, and the comparison of quantitative parameters of glioma between low-and high-grade, which was detected by Mann-Whitney U test. The receiver operation characteristic (ROC) curve was drawn to take the value of ADC and FA in tumor ROI as a critical point, to calculate the area under the curve and to confirm the diagnosis threshold value and evaluate its diagnostic efficiency. The FA value of 14 low-grade glioma cases was 139.4 +/- 81.3, with an ADC value of (1.36 +/- 0.21) x10(-3) mm(2)/sec. The FA value of 17 high-grade glioma cases was 103.1 +/- 41.5, with ADC value of (1.09 +/- 0.28) -3 mm(2)/sec; the difference between the two groups was statistically significant (P<0.05). The ADC value was taken as the critical point to judge tumor grade and draw the ROC curve; the area under the curve was 0.79. As the diagnosis threshold value, the ADC value of 1.11x10(-3) mm(2)/sec was used to distinguish between low-and high-grade tumor with a sensitivity of 58.8% and specificity of 92.9%. The FA value was taken as a critical point to judge tumor grade and draw the ROC curve; the area under the curve was 0.62. As the diagnosis threshold value, the FA value of 178.9 was applied to distinguish between low-and high-grade tumor sensitivity of 94.1% and specificity of 35.7%. Therefore, the FA value and ADC value in DTI has an important estimated value for the pathological grade of glioma.
引用
收藏
页码:2009 / 2014
页数:6
相关论文
共 50 条
  • [31] Clinical Application of Diffusion Tensor Imaging it Diagnosis and Prognosis of Hemifacial Spasm
    Jin, Zhuoru
    Li, Zhipeng
    WORLD NEUROSURGERY, 2021, 145 : E14 - E20
  • [32] Diffusion-tensor fiber tractography: Intraindividual comparison of 3.0-T and 1.5-T MR imaging
    Okada, T
    Miki, Y
    Fushimi, Y
    Hanakawa, T
    Kanagaki, M
    Yamamoto, A
    Urayama, S
    Fukuyama, H
    Hiraoka, M
    Togashi, K
    RADIOLOGY, 2006, 238 (02) : 668 - 678
  • [33] 3.0T MR Imaging of the Cranial Arterial Wall for the Strategy of Stroke Prevention
    Koga, H.
    Oishi, T.
    NEURORADIOLOGY JOURNAL, 2011, 24 (01): : 101 - 114
  • [34] The value of 3.0T MR high-b-value DWIBS in detecting the cerebral metastases
    Wang, Ying
    Xu, Qin-yan
    Zhang, Ye
    Wang, Xi-zhen
    Sun, Xi-he
    Guan, Yue
    Ge, Yan-ming
    Chang, Guang-hui
    2015 8TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI), 2015, : 116 - 120
  • [35] Diffusion tensor imaging characterization of occult brain damage in relapsing neuromyelitis optica using 3.0T magnetic resonance imaging techniques
    Zhao, Dai-Di
    Zhou, Hong-Yu
    Wu, Qi-Zhu
    Liu, Ju
    Chen, Xiu-Ying
    He, Dian
    He, Xiao-Fei
    Han, Wen-Jie
    Gong, Qi-Yong
    NEUROIMAGE, 2012, 59 (04) : 3173 - 3177
  • [36] MR tractography with diffusion tensor imaging in clinical routine
    T. H. Nguyen
    M. Yoshida
    J. L. Stievenart
    M. T. Iba-Zizen
    L. Bellinger
    A. Abanou
    K. Kitahara
    E. A. Cabanis
    Neuroradiology, 2005, 47 : 334 - 343
  • [37] MR tractography with diffusion tensor imaging in clinical routine
    Nguyen, T
    Yoshida, M
    Stievenart, JL
    Iba-Zizen, MT
    Bellinger, L
    Abanou, A
    Kitahara, K
    Cabanis, EA
    NEURORADIOLOGY, 2005, 47 (05) : 334 - 343
  • [38] Diffusion Tensor MR Imaging of Cerebral Gliomas: Evaluating Fractional Anisotropy Characteristics
    White, M. L.
    Zhang, Y.
    Yu, F.
    Kazmi, S. A. Jaffar
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (02) : 374 - 381
  • [39] MR imaging and outcome in neonatal HIBD models are correlated with sex: the value of diffusion tensor MR imaging and diffusion kurtosis MR imaging
    Bao, Jieaoxue
    Zhang, Xiaoan
    Zhao, Xin
    FRONTIERS IN NEUROSCIENCE, 2023, 17
  • [40] Quantitative Diffusion Tensor Imaging Analysis of Low-Grade Gliomas: From Preclinical Application to Patient Care
    Ius, Tamara
    Turella, Luca
    Pauletto, Giada
    Isola, Miriam
    Maieron, Marta
    Sciacca, Giovanni
    Budai, Riccardo
    D'Agostini, Serena
    Eleopra, Roberto
    Skrap, Miran
    WORLD NEUROSURGERY, 2017, 97 : 333 - 343