The Utility of a Wireless Implantable Hemodynamic Monitoring System in Patients Requiring Mechanical Circulatory Support

被引:25
|
作者
Feldman, David S. [1 ,4 ]
Moazami, Nader [2 ]
Adamson, Philip B. [3 ]
Vierecke, Juliane [4 ]
Raval, Nir [5 ]
Shreenivas, Satya [1 ]
Cabuay, Barry M. [6 ]
Jimenez, Javier [7 ]
Abraham, William T. [8 ]
O'Connell, John B. [3 ]
Naka, Yoshifumi [9 ]
机构
[1] Univ Cincinnati, Med Ctr, Div Cardiovasc Med, Cincinnati, OH USA
[2] Cleveland Clin Fdn, Cardiothorac Surg, 9500 Euclid Ave, Cleveland, OH 44195 USA
[3] St Jude Med, Sect Adv Med Therapies, St Paul, MN USA
[4] Univ Bern, Div Cardiol, Bern, Switzerland
[5] Florida Hosp Transplant Inst, Orlando, FL USA
[6] Minneapolis Heart Inst, Dept Cardiol, Minneapolis, MN USA
[7] South Miami Hosp, Div Cardiol, South Miami, FL USA
[8] Ohio State Univ, Med Ctr, Div Cardiovasc Med, Columbus, OH 43210 USA
[9] Columbia Univ, Med Ctr, Div Cardiothorac Surg, New York, NY USA
关键词
hemodynamic monitoring; mechanical circulatory support; left ventricular assist device; heart failure; pulmonary wedge pressure; heart transplantation; PULMONARY-ARTERY PRESSURE; ADVANCED HEART-FAILURE; INTERMACS ANNUAL-REPORT; DEVICE; EFFICACY; THERAPY; TRIAL;
D O I
10.1097/MAT.0000000000000670
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Proper timing of left ventricular assist device (LVAD) implantation in advanced heart failure patients is not well established and is an area of intense interest. In addition, optimizing LVAD performance after implantation remains difficult and represents a significant clinical need. Implantable hemodynamic monitoring systems may provide physicians with the physiologic information necessary to improve the timing of LVAD implantation as well as LVAD performance when compared with current methods. The CardioMEMS Heart sensor Allows for Monitoirng of Pressures to Improve Outcomes in NYHA Class III heart failure patients (CHAMPION) Trial enrolled 550 previously hospitalized patients with New York Heart Association (NYHA) class III heart failure. All patients were implanted with a pulmonary artery (PA) pressure monitoring system and randomized to a treatment and control groups. In the treatment group, physicians used the hemodynamic information to make heart failure management decisions. This information was not available to physicians for the control group. During an average of 18 month randomized follow-up, 27 patients required LVAD implantation. At the time of PA pressure sensor implantation, patients ultimately requiring advanced therapy had higher PA pressures, lower systemic pressure, and similar cardiac output measurements. Treatment and control patients in the LVAD subgroup had similar clinical profiles at the time of enrollment. There was a trend toward a shorter length of time to LVAD implantation in the treatment group when hemodynamic information was available. After LVAD implantation, most treatment group patients continued to provide physicians with physiologic information from the hemodynamic monitoring system. As expected PA pressures declined significantly post LVAD implant in all patients, but the magnitude of decline was higher in patients with PA pressure monitoring. Implantable hemodynamic monitoring appeared to improve the timing of LVAD implantation as well as optimize LVAD performance when compared with current methods. Further studies are necessary to evaluate these findings in a prospective manner.
引用
收藏
页码:301 / 308
页数:8
相关论文
共 50 条
  • [41] Flecainide Toxicity On An Existing Long QT Requiring Mechanical Circulatory Support
    Caudill, Andrea
    Deicke, Matthew
    Oehler, Andrew
    JOURNAL OF CARDIAC FAILURE, 2024, 30 (01) : 224 - 225
  • [42] Circulatory collapse requiring mechanical circulatory support in a child with autoimmune adrenal insufficiency: a case report
    Hejazi, Yahia
    Tegtmeyer, Ken
    Chlebowski, Meghan
    Gist, Katja M.
    BMC PEDIATRICS, 2024, 24 (01)
  • [43] Mechanical Circulatory Support in Dialysis Patients
    Boyle, A. J.
    Savitt, M. A.
    Sulemanjee, N. Z.
    Hastings, T. E.
    Crouch, J. D.
    Warren, G. V.
    Wallach, J. D.
    Nagendran, K.
    Anigbogu, M. E.
    Downey, F. X.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2011, 30 (04): : S213 - S214
  • [44] Mechanical circulatory support in pediatric patients
    M. Beghetti
    P. C. Rimensberger
    Intensive Care Medicine, 2000, 26 : 350 - 352
  • [45] Infections in Patients with Mechanical Circulatory Support
    Eichenberger, Emily M.
    Phadke, Varun
    Busch, Lindsay M.
    Pouch, Stephanie M.
    INFECTIOUS DISEASE CLINICS OF NORTH AMERICA, 2024, 38 (04) : 693 - 712
  • [46] Mechanical circulatory support in pediatric patients
    Beghetti, M
    Rimensberger, PC
    INTENSIVE CARE MEDICINE, 2000, 26 (03) : 350 - 352
  • [47] Mechanical circulatory support in paediatric patients
    Polo, Luz
    Sanchez, Rani
    Aroca, Angel
    CIRUGIA CARDIOVASCULAR, 2016, 23 : 55 - 61
  • [48] A Novel Fully Implantable Wireless Sensor System for Monitoring Hypertension Patients
    Cleven, Nina J.
    Muentjes, Jutta A.
    Fassbender, Holger
    Urban, Ute
    Goertz, Michael
    Vogt, Holger
    Graefe, Maik
    Goettsche, Thorsten
    Penzkofer, Tobias
    Schmitz-Rode, Thomas
    Mokwa, Wilfried
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2012, 59 (11) : 3124 - 3130
  • [49] Integrated Home Monitoring and Compliance Optimization for Patients with Mechanical Circulatory Support Devices
    Klack, Lars
    Schmitz-Rode, Thomas
    Wilkowska, Wiktoria
    Kasugai, Kai
    Heidrich, Felix
    Ziefle, Martina
    ANNALS OF BIOMEDICAL ENGINEERING, 2011, 39 (12) : 2911 - 2921
  • [50] Integrated Home Monitoring and Compliance Optimization for Patients with Mechanical Circulatory Support Devices
    Lars Klack
    Thomas Schmitz-Rode
    Wiktoria Wilkowska
    Kai Kasugai
    Felix Heidrich
    Martina Ziefle
    Annals of Biomedical Engineering, 2011, 39 : 2911 - 2921