Palmar angular stable plate fixation of nonunions and comminuted fractures of the scaphoid

被引:0
|
作者
Quadlbauer, S. [1 ,2 ,3 ]
Pezzei, C. [1 ]
Jurkowitsch, J. [1 ]
Krimmer, H. [4 ]
Sauerbier, M. [5 ]
Hausner, T. [1 ,2 ,3 ,5 ,6 ]
Leixnering, M. [1 ]
机构
[1] AUVA Unfallkrankenhaus Lorenz Bohler, European Hand Trauma Ctr, Donaueschingenstr 13, A-1200 Vienna, Austria
[2] AUVA Res Ctr, Ludwig Boltzmann Inst Expt & Klin Traumatol, Vienna, Austria
[3] Austrian Cluster Tissue Regenerat, Vienna, Austria
[4] St Elisabeth Klinikum Ravensburg, Zentrum Handchirurg, Ravensburg, Germany
[5] BG Unfallklin Frankfurt Main, Abt Plast Hand & Rekonstrukt Chirurg, Frankfurt, Germany
[6] Paracelsius Med Univ, Abt Orthopadie & Traumatol, Salzburg, Austria
来源
关键词
Bone graft; Scaphoid; Non union; Rotational stability; Plate; VASCULARIZED BONE-GRAFT; INTERNAL-FIXATION; SCREW FIXATION; PROXIMAL POLE; DISTAL RADIUS; NON-UNIONS; WAIST; PSEUDOARTHROSIS; RELIABILITY; MANAGEMENT;
D O I
10.1007/s00064-019-00623-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective Stabilization of comminuted fractures and nonunions of the scaphoid with an angular stable low-profile scaphoid plate. Indications Scaphoid nonunions with a large palmar defect, second and third surgical procedure after previous stabilization by headless compression screw (HCS). Comminuted fractures of the scaphoid that cannot be sufficiently stabilized by screws. Contraindications Radio- and midcarpal osteoarthritis, small proximal pole fragments, fragmentation of the proximal pole. Surgical technique The scaphoid is accessed by a palmar approach. After correcting the DISI (dorsal intercalated segment instability) deformity of the lunate and humpback deformity of the scaphoid, the reduction is secured by temporary Kirschner wires. The nonunion is debrided and the bone defect filled with cancellous bone graft. Subsequently the scaphoid plate and the angular stable screw are positioned in the order to place three screws in the proximal and distal fragment of the scaphoid. Comminuted fractures of the scaphoid are fixated by temporary Kirschner wires, then the plate is positioned in the same way as nonunions. Postoperative management Comminuted fractures and nonunions of the scaphoid are immobilized by a below-elbow cast or thermoplastic splint with inclusion of the thumb for 8 weeks. No heavy work, high-risk or contact sport activities for 12 weeks. Plate removal is recommended after 6 months or after bony healing. Results By stabilizing scaphoid nonunions with a plate, high union rates with good clinical outcome can be achieved if the indication is correct.
引用
收藏
页码:433 / 446
页数:14
相关论文
共 50 条
  • [41] Is Arthroscopic Bone Graft and Fixation for Scaphoid Nonunions Effective?
    Kang, Ho Jung
    Chun, Yong-Min
    Koh, Il Hyun
    Park, Jae Han
    Choi, Yun Rak
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2016, 474 (01) : 204 - 212
  • [42] Comparison of fixation methods for scaphoid nonunions: a biomechanical model
    Panchal, Anand
    Kubiak, Erik
    Keshner, Mitchell
    Fulkerson, Eric
    Paskima, Nader
    EKLEM HASTALIKLARI VE CERRAHISI-JOINT DISEASES AND RELATED SURGERY, 2007, 18 (02): : 66 - 71
  • [43] Medial Comminution as Prognostic Factor after Angular Stable Plate Fixation of Proximal Humeral Fractures
    Osterhoff, Georg
    Hoch, Armando
    Wanner, Guido A.
    Simmen, Hans-Peter
    Wemer, Clement M. L.
    SWISS MEDICAL WEEKLY, 2012, 142 : S11 - S11
  • [44] STABLE COMPRESSION PLATE FIXATION OF MANDIBULAR FRACTURES
    BECKER, R
    BRITISH JOURNAL OF ORAL SURGERY, 1974, 12 (01): : 13 - 23
  • [45] Valgising angular stable plate fixation in the treatment of multifragmentary proximal humeral fractures in elderly patients
    Burkus, Mate
    Bruch, A.
    Bergmann, E. M.
    Karahodzic-Franjic, M.
    Zdichavsky, M.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (04) : 1637 - 1645
  • [46] Valgising angular stable plate fixation in the treatment of multifragmentary proximal humeral fractures in elderly patients
    Máté Burkus
    A. Bruch
    E. M. Bergmann
    M. Karahodzic-Franjic
    M. Zdichavsky
    Archives of Orthopaedic and Trauma Surgery, 2024, 144 : 1637 - 1645
  • [47] Management of acute fractures and nonunions of the proximal pole of the scaphoid
    Krimmer, H
    JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2002, 27B (03): : 245 - 248
  • [48] The palmar locking compression plate is biomechanically comparable to the dorsal Pi plate for dorsally comminuted, intraarticular wrist fractures
    Hart, A. J.
    Seepaul, T.
    Hewitt, R. J.
    Ang, S.
    Hansen, U.
    Amis, A. A.
    JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2007, 32E (04): : 388 - 393
  • [49] Locking Versus Nonlocking Palmar Plate Fixation of Distal Radius Fractures
    Osti, Michael
    Mittler, Christoph
    Zinnecker, Richard
    Westreicher, Christoph
    Allhoff, Clemens
    Benedetto, Karl Peter
    ORTHOPEDICS, 2012, 35 (11) : E1613 - E1617
  • [50] Outcomes of Local Bone Graft and Fixation of Proximal Pole Scaphoid Nascent Nonunions and Nonunions
    Shoji, Kristin E.
    Simeone, F. Joseph
    Ozkan, Sezai
    Mudgal, Chaitanya S.
    JOURNAL OF WRIST SURGERY, 2020, 9 (03) : 203 - 208