Palmar angular stable plate fixation of nonunions and comminuted fractures of the scaphoid

被引:0
|
作者
Quadlbauer, S. [1 ,2 ,3 ]
Pezzei, C. [1 ]
Jurkowitsch, J. [1 ]
Krimmer, H. [4 ]
Sauerbier, M. [5 ]
Hausner, T. [1 ,2 ,3 ,5 ,6 ]
Leixnering, M. [1 ]
机构
[1] AUVA Unfallkrankenhaus Lorenz Bohler, European Hand Trauma Ctr, Donaueschingenstr 13, A-1200 Vienna, Austria
[2] AUVA Res Ctr, Ludwig Boltzmann Inst Expt & Klin Traumatol, Vienna, Austria
[3] Austrian Cluster Tissue Regenerat, Vienna, Austria
[4] St Elisabeth Klinikum Ravensburg, Zentrum Handchirurg, Ravensburg, Germany
[5] BG Unfallklin Frankfurt Main, Abt Plast Hand & Rekonstrukt Chirurg, Frankfurt, Germany
[6] Paracelsius Med Univ, Abt Orthopadie & Traumatol, Salzburg, Austria
来源
关键词
Bone graft; Scaphoid; Non union; Rotational stability; Plate; VASCULARIZED BONE-GRAFT; INTERNAL-FIXATION; SCREW FIXATION; PROXIMAL POLE; DISTAL RADIUS; NON-UNIONS; WAIST; PSEUDOARTHROSIS; RELIABILITY; MANAGEMENT;
D O I
10.1007/s00064-019-00623-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective Stabilization of comminuted fractures and nonunions of the scaphoid with an angular stable low-profile scaphoid plate. Indications Scaphoid nonunions with a large palmar defect, second and third surgical procedure after previous stabilization by headless compression screw (HCS). Comminuted fractures of the scaphoid that cannot be sufficiently stabilized by screws. Contraindications Radio- and midcarpal osteoarthritis, small proximal pole fragments, fragmentation of the proximal pole. Surgical technique The scaphoid is accessed by a palmar approach. After correcting the DISI (dorsal intercalated segment instability) deformity of the lunate and humpback deformity of the scaphoid, the reduction is secured by temporary Kirschner wires. The nonunion is debrided and the bone defect filled with cancellous bone graft. Subsequently the scaphoid plate and the angular stable screw are positioned in the order to place three screws in the proximal and distal fragment of the scaphoid. Comminuted fractures of the scaphoid are fixated by temporary Kirschner wires, then the plate is positioned in the same way as nonunions. Postoperative management Comminuted fractures and nonunions of the scaphoid are immobilized by a below-elbow cast or thermoplastic splint with inclusion of the thumb for 8 weeks. No heavy work, high-risk or contact sport activities for 12 weeks. Plate removal is recommended after 6 months or after bony healing. Results By stabilizing scaphoid nonunions with a plate, high union rates with good clinical outcome can be achieved if the indication is correct.
引用
收藏
页码:433 / 446
页数:14
相关论文
共 50 条
  • [1] Palmare winkelstabile Verplattung von Pseudarthrosen und Trümmerfrakturen des KahnbeinsPalmar angular stable plate fixation of nonunions and comminuted fractures of the scaphoid
    S. Quadlbauer
    C. Pezzei
    J. Jurkowitsch
    H. Krimmer
    M. Sauerbier
    T. Hausner
    M. Leixnering
    Operative Orthopädie und Traumatologie, 2019, 31 (5) : 433 - 446
  • [2] Palmar Plate Fixation in Scaphoid Nonunions-Surgical Technique and Review of the Literature
    Quadlbauer, Stefan
    Pezzei, Chistoph
    Hintringer, Wolfgang
    Beer, Thomas
    Hausner, Thomas
    Leixnering, Martin
    Jurkowitsch, Josef
    JOURNAL OF WRIST SURGERY, 2024,
  • [3] Double screw versus angular stable plate fixation of scaphoid waist nonunions in combination with intraoperative extracorporeal shockwave therapy (ESWT)
    Quadlbauer, S.
    Pezzei, Ch.
    Jurkowitsch, J.
    Beer, T.
    Moser, V.
    Rosenauer, R.
    Salminger, S.
    Hausner, T.
    Leixnering, M.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (07) : 4565 - 4574
  • [4] Double screw versus angular stable plate fixation of scaphoid waist nonunions in combination with intraoperative extracorporeal shockwave therapy (ESWT)
    S. Quadlbauer
    Ch. Pezzei
    J. Jurkowitsch
    T. Beer
    V. Moser
    R. Rosenauer
    S. Salminger
    T. Hausner
    M. Leixnering
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 4565 - 4574
  • [5] Customized mini-plate for scaphoid fractures and nonunions
    Spagnoli, A. M.
    Rizzo, M. I.
    Sorvillo, V.
    Scuderi, N.
    GIORNALE DI CHIRURGIA, 2011, 32 (03): : 150 - 152
  • [6] Comparative analysis of scaphoid nonunion treatment with screw fixation and angular stable plate
    Nakamoto, Joao Carlos
    Xavier, Renato Martins
    Burgos, Felipe Hellmeister
    Wataya, Erick Yoshio
    do Carmo Iwase, Fernanda
    Nakamoto, Hugo Alberto
    Mattar Junior, Rames
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (04) : 2247 - 2253
  • [7] Comparative analysis of scaphoid nonunion treatment with screw fixation and angular stable plate
    João Carlos Nakamoto
    Renato Martins Xavier
    Felipe Hellmeister Burgos
    Erick Yoshio Wataya
    Fernanda do Carmo Iwase
    Hugo Alberto Nakamoto
    Rames Mattar Júnior
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 2247 - 2253
  • [8] Volar locking and angular stability plate for treatment of comminuted scaphoid fractures: a case series of 44 cases
    Marzella, L.
    Filistad, S.
    Lazzerini, A.
    Cannella, A.
    Sassara, G.
    Caruso, L.
    De Vitis, R.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2024, 34 (08): : 4001 - 4008
  • [9] Percutaneous plate fixation of comminuted ulnar fractures
    Karistinos, A
    Olmedo, ML
    Albright, JA
    ORTHOPEDICS, 2005, 28 (11) : 1320 - 1321
  • [10] Treatment of scaphoid fractures and nonunions
    Kawamura, Kenji
    Chung, Kevin C.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2008, 33A (06): : 988 - 997