Harmonics Mitigation of Stand-Alone Photovoltaic System Using LC Passive Filter

被引:22
|
作者
Adak, Suleyman [1 ]
机构
[1] Mardin Artuklu Univ, Dept Elect & Energy, Mardin, Turkey
关键词
Six-pulse rectifier; Total harmonic distortion for current; Passive LC filter; Off-grid photovoltaic system;
D O I
10.1007/s42835-021-00777-7
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article investigates modeling and simulation of the off-grid photovoltaic (PV) system, and elimination of harmonic components using an LC passive filter. Pulse width modulation (PWM) inverter is used to convert the direct current to alternating current. It is very important in terms of energy quality that the inverter output current total harmonic distortion (THDI) is below the value given by standards. Harmonic components have negatively effect on off-grid PV power system. THDI should be kept below a certain level in order to prevent damage to the equipment in the off-grid system and to ensure a higher quality energy flow to reduce the total harmonic distortion (THD) of the solar inverter output current; LC passive filter must be connected to the output of the PWM inverter. There are many types of passive filters for solar inverters. One of the most widely used filter types is the LC filter. LC filters are used in off-grid systems. LC filter is smaller in size and lower cost than other filters. But it is more complicated to determine the parameters of the LC filter. Therefore, in order for the system to remain in a steady state, the parameters must be accurately calculated and analyzed. In this study, the output power of the solar inverter, switching frequency, bus voltage etc. values were determined and LC filter parameters were calculated. Since high inductance values are used in LC filters, the voltage drop increases in these filters. To reduce the voltage drop, the DC bus voltage must be increased, which increases the switching losses. LC filter is connected between the inverter and the nonlinear load to filter the harmonic components produced by the DC/DC boost converter, DC/AC inverter and non-linear load. Matlab/Simulink program was used in Simulation and analysis of off-grid solar system. Solar inverter output current THD was measured as 91.55%. After the LC filter is connected to the system, this value has dropped to 2.62%.
引用
收藏
页码:2389 / 2396
页数:8
相关论文
共 50 条
  • [41] Photovoltaic Module Simulink Model for a Stand-alone PV System
    Qi, Chen
    Ming, Zhu
    INTERNATIONAL CONFERENCE ON APPLIED PHYSICS AND INDUSTRIAL ENGINEERING 2012, PT A, 2012, 24 : 94 - 100
  • [42] A STAND-ALONE HYBRID PHOTOVOLTAIC, FUEL CELL AND BATTERY SYSTEM
    Qandil, Mohammad D.
    Amano, Ryoichi S.
    Abbas, Ahmad I.
    PROCEEDINGS OF THE ASME 12TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, 2018, 2018,
  • [43] A battery management system for stand-alone photovoltaic energy systems
    Duryea, S
    Islam, S
    Lawrance, W
    IEEE INDUSTRY APPLICATIONS MAGAZINE, 2001, 7 (03) : 67 - 72
  • [44] Analysis, Modeling, and Control of a Stand-alone Photovoltaic Generation System
    ElMehdi, Abosalah
    Johnson, Brian
    Abuagreb, Mohamed
    Parker, William
    2016 4TH INTERNATIONAL CONFERENCE ON CONTROL ENGINEERING & INFORMATION TECHNOLOGY (CEIT), 2016,
  • [45] A novel storage system for cooling stand-alone photovoltaic installations
    Lillo-Bravo, I
    Bobadilla, M. A.
    Moreno-Tejera, S.
    Silva-Perez, M.
    RENEWABLE ENERGY, 2020, 155 (155) : 23 - 37
  • [46] Performance Analysis of a Stand-alone Building Integrated Photovoltaic System
    Overen, Ochuko K.
    Meyer, Edson L.
    PROCEEDINGS OF THE ISES SOLAR WORLD CONFERENCE 2019 AND THE IEA SHC SOLAR HEATING AND COOLING CONFERENCE FOR BUILDINGS AND INDUSTRY 2019, 2019, : 1654 - 1661
  • [47] Energy Management Control Strategy for Stand-alone Photovoltaic System
    Magaldi, Guillermo L.
    Serra, Federico M.
    Silva, Luis I.
    2015 XVI WORKSHOP ON INFORMATION PROCESSING AND CONTROL (RPIC), 2015,
  • [48] Performance and cost evaluation of a stand-alone photovoltaic system in Malta
    Iskander, C
    Scerri, E
    RENEWABLE ENERGY, 1996, 8 (1-4) : 437 - 440
  • [49] Study of EDLC and Its Usage in Stand-alone Photovoltaic System
    Li, Baohua
    Pan, Xuesong
    He, Yan-Bing
    Du, Hongda
    ADVANCED MATERIALS AND STRUCTURES, PTS 1 AND 2, 2011, 335-336 : 1368 - 1375
  • [50] Distributed Energy Management for Stand-Alone Photovoltaic System with Storages
    Cho, Jae Hoon
    Hwa-Kim, Dong
    UBIQUITOUS COMPUTING AND MULTIMEDIA APPLICATIONS, PT II, 2011, 151 : 98 - +