Comparison of calibration procedures of iridium-192 sources used in high dose rate brachytherapy system

被引:0
|
作者
Kumar, A [1 ]
Singh, S
Agrawal, S
机构
[1] Indira Gandhi Inst Med Sci, Reg Canc Ctr, Patna, Bihar, India
[2] AN Coll, Patna, Bihar, India
关键词
iridum-192; brachytherapy system; calibration;
D O I
暂无
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Calibration of iridium-192 high dose rate (HDR) brachytherapy sources has been compared by using two independent systems. Two types of calibration systems, well-type chamber (SDS), and field dosimeter (0.6 cc graphite thimble) with nucletron calibration jig have been compared. A number of measurements have been performed to calibrate the six iridium-192 sources according to national/international protocol during the clinical half-life of the iridium-192 source. All influencing factors like room-scattering, positional errors and accuracy of source position etc. have been taken care of, because the accuracy of source position itself within the applicator can lead to an error of +/-1.2% for the radial distance of 10 cm used in the calibration jig. Taking the 0.6 cc graphite thimble results as reference, percentage root mean square error (RMS) value of 0.33% for well-type chamber has been observed. It has been found that, both the calibration systems are equally good and can, determine accurate and quick source calibration with careful measurements. Further, it should be mandatory to calibrate the source, prior to use of the source for the treatment of patients.
引用
收藏
页码:253 / 257
页数:5
相关论文
共 50 条
  • [31] Dosimetric comparison between microSelectron iridium-192 and flexi cobalt-60 sources in high-dose-rate brachytherapy using Geant4 Monte Carlo code
    Gebremariam, Tsige Yhidego
    Geraily, Ghazale
    Jassim, Hussam Hameed
    Gholami, Somayeh
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2023, 15 (02) : 141 - 147
  • [32] Calibration of pre-cut iridium-192 wires for low dose rate interstitial brachytherapy using a Farmer-type ionization chamber
    Vollans, SE
    Wilkinson, JM
    BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (866): : 201 - 205
  • [33] Dosimetric Comparison of Iridium-192, Ytterbium-169, and Thulium-170 Sources for HDR Prostate Brachytherapy
    Krishnamurthy, D.
    Cunha, J.
    Hsu, I.
    Weinberg, V.
    Pouliot, J.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [34] Dosimetric characterization of the M-15 high-dose-rate Iridium-192 brachytherapy source using the AAPM and ESTRO formalism
    Minh-Tri Ho Thanh
    Munro, John J., III
    Medich, David C.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (03): : 305 - 317
  • [35] Single dose irradiation response of pig skin: a comparison of brachytherapy using a single, high dose rate iridium-192 stepping source with 200 kV X-rays
    Hamm, PCJ
    Bakker, EJ
    van den Berg, AP
    van den Aardweg, GJMJ
    Visser, AG
    Levendag, PC
    BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (871): : 762 - 770
  • [36] Dosimetric Considerations for Ytterbium-169, Selenium-75, and Iridium-192 Radioisotopes in High-Dose-Rate Endorectal Brachytherapy
    Shoemaker, Tristan
    Te Vuong
    Glickman, Harry
    Kaifi, Samar
    Famulari, Gabriel
    Enger, Shirin A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (04): : 875 - 883
  • [37] High dose-rate brachytherapy of prostate cancer utilising Iridium-192 after-loading technique:: Technical and methodological aspects
    Edgren, M.
    Ekelund, A. M.
    Albertsson, P.
    Lundberg, L. M.
    Ullen, A.
    Levitt, S.
    Nilsson, S.
    Lennernas, B.
    INTERNATIONAL JOURNAL OF ONCOLOGY, 2006, 29 (06) : 1517 - 1524
  • [38] Comments on the calibration of pre-cut iridium-192 wires for low dose rate interstitial brachytherapy using a Farmer-type ionization chamber
    Plane, JH
    BRITISH JOURNAL OF RADIOLOGY, 2001, 74 (879): : 291 - 292
  • [39] Radiation exposure to the kidney with interstitial iridium-192 high-dose-rate brachytherapy: Extent and rare morphologic changes of radiation nephropathy
    March, Christine
    Thormann, Maximilian
    Hass, Peter
    Seidensticker, Max
    Gross, Christian
    Omari, Jazan
    Pech, Maciej
    Damm, Robert
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2022, 14 (06) : 512 - 518
  • [40] A dosimetric comparison of brachytherapy sources for endometrial cancer: an electronic brachytherapy and an iridium-192 source with multichannel cylinders and a three-dimensional technique
    Wang, Wenhui
    Wang, Bei
    Yu, Lang
    Zhen, Hongnan
    Zhang, Yue
    Feng, Siqi
    Chen, Zhou
    Zhang, Yuan
    Qiu, Jie
    Zhang, Fuquan
    Hu, Ke
    BMC CANCER, 2024, 24 (01)