Comparison of calibration procedures of iridium-192 sources used in high dose rate brachytherapy system

被引:0
|
作者
Kumar, A [1 ]
Singh, S
Agrawal, S
机构
[1] Indira Gandhi Inst Med Sci, Reg Canc Ctr, Patna, Bihar, India
[2] AN Coll, Patna, Bihar, India
关键词
iridum-192; brachytherapy system; calibration;
D O I
暂无
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Calibration of iridium-192 high dose rate (HDR) brachytherapy sources has been compared by using two independent systems. Two types of calibration systems, well-type chamber (SDS), and field dosimeter (0.6 cc graphite thimble) with nucletron calibration jig have been compared. A number of measurements have been performed to calibrate the six iridium-192 sources according to national/international protocol during the clinical half-life of the iridium-192 source. All influencing factors like room-scattering, positional errors and accuracy of source position etc. have been taken care of, because the accuracy of source position itself within the applicator can lead to an error of +/-1.2% for the radial distance of 10 cm used in the calibration jig. Taking the 0.6 cc graphite thimble results as reference, percentage root mean square error (RMS) value of 0.33% for well-type chamber has been observed. It has been found that, both the calibration systems are equally good and can, determine accurate and quick source calibration with careful measurements. Further, it should be mandatory to calibrate the source, prior to use of the source for the treatment of patients.
引用
收藏
页码:253 / 257
页数:5
相关论文
共 50 条
  • [1] Calibration of iridium-192 source by ionization chamber for high dose rate brachytherapy
    Gadhi, M. A.
    Buzdar, S. A.
    Afzal, M.
    Fatmi, Sh.
    Akhtar, M. S.
    Nizamani, A. H.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2013, 11 (03): : 189 - 193
  • [2] Comparison of calibration procedures for 192IR high-dose-rate brachytherapy sources
    Baltas, D
    Geramani, K
    Ioannidis, GT
    Hierholz, K
    Rogge, B
    Kolotas, C
    Müller-Sievers, K
    Milickovic, N
    Kober, B
    Zamboglou, N
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 43 (03): : 653 - 661
  • [3] Four year clinical statistics of iridium-192 high dose rate brachytherapy
    Shigehara, K
    Mizokami, A
    Komatsu, K
    Koshida, K
    Namiki, M
    INTERNATIONAL JOURNAL OF UROLOGY, 2006, 13 (02) : 116 - 121
  • [4] Comparison of high-dose rate prostate brachytherapy dose distributions with iridium-192, ytterbium-169, and thulium-170 sources
    Krishnamurthy, Devan
    Weinberg, Vivian
    Cunha, J. Adam M.
    Hsu, I-Chow
    Pouliot, Jean
    BRACHYTHERAPY, 2011, 10 (06) : 461 - 465
  • [5] Determination of the tissue inhomogeneity correction in high dose rate Brachytherapy for Iridium-192 source
    Ravikumar, Barlanka
    Lakshminarayana, S.
    JOURNAL OF MEDICAL PHYSICS, 2012, 37 (01) : 27 - 31
  • [6] Clinical Results of Iridium-192 High Dose Rate Brachytherapy with External Beam Radiotherapy
    Nohara, Takahiro
    Mizokami, Atsushi
    Kumano, Tomoyasu
    Shigehara, Kazuyoshi
    Konaka, Hiroyuki
    Yoshifumi, Kadono
    Yasuhide, Kitagawa
    Izumi, Kouji
    Narimoto, Kazutaka
    Namiki, Mikio
    JAPANESE JOURNAL OF CLINICAL ONCOLOGY, 2010, 40 (07) : 677 - 683
  • [7] Absorbed dose simulations in near-surface regions using high dose rate Iridium-192 sources applied for brachytherapy
    Moura, E. S.
    Zeituni, C. A.
    Sakuraba, R. K.
    Goncalves, V. D.
    Cruz, J. C.
    Junior, D. K.
    Souza, C. D.
    Rostelato, M. E. C. M.
    RADIATION PHYSICS AND CHEMISTRY, 2014, 95 : 299 - 301
  • [8] A dosimetric comparison of Xoft Axxent Electronic Brachytherapy and iridium-192 high-dose-rate brachytherapy in the treatment of endometrial cancer
    Dickler, Adam
    Kirk, Michael C.
    Coon, Alan
    Bernard, Damian
    Zusag, Tom
    Rotmensch, Jacob
    Wazer, David E.
    BRACHYTHERAPY, 2008, 7 (04) : 351 - 354
  • [9] CALIBRATION OF BRACHYTHERAPY IRIDIUM 192 SOURCES
    COBB, PD
    BJARNGARD, BE
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1974, 120 (01) : 211 - 212
  • [10] Comparing Iridium-192 with Cobalt-60 sources in high-dose-rate brachytherapy boost for localized prostate cancer
    Tamihardja, Joerg
    Weick, Stefan
    Lutyj, Paul
    Zimmermann, Marcus
    Bratengeier, Klaus
    Flentje, Michael
    Polat, Buelent
    ACTA ONCOLOGICA, 2022, 61 (06) : 714 - 719