The effect of magnetic resonance imaging on mercury release from dental amalgam at 3T and 7T

被引:1
|
作者
Allison, James R. [1 ,2 ,3 ,7 ]
Chary, Karthik [3 ,4 ]
Ottley, Chris [5 ]
Vuong, Quoc C. [6 ]
German, Matthew J. [1 ,3 ]
Durham, Justin [1 ,2 ]
Thelwall, Peter [3 ,4 ]
机构
[1] Newcastle Univ, Fac Med Sci, Sch Dent Sci, Newcastle, England
[2] NHS Fdn Trust, Newcastle Tyne Hosp, Newcastle Upon Tyne, Northumberland, England
[3] Newcastle Univ, Translat & Clin Res Inst, Fac Med Sci, Newcastle, England
[4] Newcastle Univ, Ctr Vivo Imaging, Newcastle Upon Tyne, Northumberland, England
[5] Univ Durham, Dept Earth Sci, Durham, England
[6] Newcastle Univ, Biosci Inst, Fac Med Sci, Newcastle, England
[7] Newcastle Univ, Fac Med Sci, Sch Dent Sci, Framlington Pl, Newcastle Upon Tyne NE2 4BW, Northumberland, England
基金
英国惠康基金;
关键词
Magnetic resonance imaging; Dental amalgam; Mercury; Dental materials; Mass spectrometry; Humans; Saliva; MRI; CORROSION; DIAGNOSIS;
D O I
10.1016/j.jdent.2022.104322
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To measure mercury release from standardised hydroxyapatite/amalgam constructs during MRI scanning and investigate the impact of static field strength and radiofrequency (RF) power on mercury release.Methods: Amalgam was placed into 140 hydroxyapatite disks and matured for 14-days in artificial saliva. The solution was replaced, and samples split into five groups of 28 immediately prior to MRI. One group had no exposure, and the remainder were exposed to either a 3T or 7T MRI scanner, each at high and low RF power. Mercury concentration was measured by inductively coupled plasma mass spectrometry. Groups were compared using one-way ANOVA, and two-way ANOVA for main effects/ interaction of field strength/ RF power.Results: Mercury concentration was increased in the 7T groups (high/ low: 15.43/ 11.33 ng mL-1) and 3T high group (3.59) compared to control (2.44). MRI field strength significantly increased mercury release (p < .001) as did RF power (p = .030). At 3T, mercury release was 20.3 times lower than during maturation of dental amalgam, and for the average person an estimated 1.50 ng kg- 1 of mercury might be released during one 3T investigation; this is substantially lower than the tolerable weekly intake of 4,000 ng kg- 1.Conclusion: Mercury release from amalgam shows a measurable increase following MRI, and the magnitude changes with magnetic field strength and RF power. The amount of mercury released is small compared to release during amalgam maturation. Amalgam mercury release during MRI is unlikely to be clinically meaningful and highly likely to remain below safe levels.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Comparing signal-to-noise ratio for prostate imaging at 7T and 3T
    Steensma, Bart R.
    Luttje, Mariska
    Voogt, Ingmar J.
    Klomp, Dennis W. J.
    Luijten, Peter R.
    van den Berg, Cornelis A. T.
    Raaijmakers, Alexander J. E.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 49 (05) : 1446 - 1455
  • [22] A comparison between 7T and 3T MR-imaging for Uveal Melanoma
    Tang, M. C. Y.
    Ferreira, T. A.
    Jaarsma-Coes, M. G.
    Marinkovic, M.
    Luyten, G. P. M.
    Beenakker, J. W. M.
    ACTA OPHTHALMOLOGICA, 2021, 99 : 26 - 27
  • [23] Spin echo based cardiac diffusion imaging at 7T: An ex vivo study of the porcine heart at 7T and 3T
    Lohr, David
    Terekhov, Maxim
    Weng, Andreas Max
    Schroeder, Anja
    Walles, Heike
    Schreiber, Laura Maria
    PLOS ONE, 2019, 14 (03):
  • [24] Neuroimaging at 3T vs 7T Is It Really Worth It?
    Jones, Stephen E.
    Lee, Jonathan
    Law, Meng
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2021, 29 (01) : 1 - 12
  • [25] Effects of X-rays and magnetic resonance imaging on mercury release from dental amalgam into artificial saliva
    S. M. J. Mortazavi
    Ghazal Mortazavi
    Oral Radiology, 2015, 31 : 199 - 200
  • [26] Effects of X-rays and magnetic resonance imaging on mercury release from dental amalgam into artificial saliva
    Sebnem Kursun
    Bengi Öztas
    Havva Atas
    Mustafa Tastekin
    Oral Radiology, 2014, 30 : 142 - 146
  • [27] Effects of X-rays and magnetic resonance imaging on mercury release from dental amalgam into artificial saliva
    Mortazavi, S. M. J.
    Mortazavi, Ghazal
    ORAL RADIOLOGY, 2015, 31 (03) : 199 - 200
  • [28] Comparison between Short and Long Echo Time Magnetic Resonance Spectroscopic Imaging at 3T and 7T for Evaluating Brain Metabolites in Patients with Glioma
    Li, Yan
    Lafontaine, Marisa
    Chang, Susan
    Nelson, Sarah J.
    ACS CHEMICAL NEUROSCIENCE, 2018, 9 (01): : 130 - 137
  • [29] Magnetic Resonance Spectroscopic Imaging at 7T (7T MRSI) abnormalities in Veterans with PTSD and mild TBI (mTBI)
    Van Cott, Anne
    Kelly, Monique
    Roberts, Jodi
    Miller, Megan
    Kontos, Anthony
    Hetherington, Hoby
    NEUROLOGY, 2017, 88
  • [30] Effects of X-rays and magnetic resonance imaging on mercury release from dental amalgam into artificial saliva
    Kursun, Sebnem
    Oztas, Bengi
    Atas, Havva
    Tastekin, Mustafa
    ORAL RADIOLOGY, 2014, 30 (02) : 142 - 146