The effect of magnetic resonance imaging on mercury release from dental amalgam at 3T and 7T

被引:1
|
作者
Allison, James R. [1 ,2 ,3 ,7 ]
Chary, Karthik [3 ,4 ]
Ottley, Chris [5 ]
Vuong, Quoc C. [6 ]
German, Matthew J. [1 ,3 ]
Durham, Justin [1 ,2 ]
Thelwall, Peter [3 ,4 ]
机构
[1] Newcastle Univ, Fac Med Sci, Sch Dent Sci, Newcastle, England
[2] NHS Fdn Trust, Newcastle Tyne Hosp, Newcastle Upon Tyne, Northumberland, England
[3] Newcastle Univ, Translat & Clin Res Inst, Fac Med Sci, Newcastle, England
[4] Newcastle Univ, Ctr Vivo Imaging, Newcastle Upon Tyne, Northumberland, England
[5] Univ Durham, Dept Earth Sci, Durham, England
[6] Newcastle Univ, Biosci Inst, Fac Med Sci, Newcastle, England
[7] Newcastle Univ, Fac Med Sci, Sch Dent Sci, Framlington Pl, Newcastle Upon Tyne NE2 4BW, Northumberland, England
基金
英国惠康基金;
关键词
Magnetic resonance imaging; Dental amalgam; Mercury; Dental materials; Mass spectrometry; Humans; Saliva; MRI; CORROSION; DIAGNOSIS;
D O I
10.1016/j.jdent.2022.104322
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To measure mercury release from standardised hydroxyapatite/amalgam constructs during MRI scanning and investigate the impact of static field strength and radiofrequency (RF) power on mercury release.Methods: Amalgam was placed into 140 hydroxyapatite disks and matured for 14-days in artificial saliva. The solution was replaced, and samples split into five groups of 28 immediately prior to MRI. One group had no exposure, and the remainder were exposed to either a 3T or 7T MRI scanner, each at high and low RF power. Mercury concentration was measured by inductively coupled plasma mass spectrometry. Groups were compared using one-way ANOVA, and two-way ANOVA for main effects/ interaction of field strength/ RF power.Results: Mercury concentration was increased in the 7T groups (high/ low: 15.43/ 11.33 ng mL-1) and 3T high group (3.59) compared to control (2.44). MRI field strength significantly increased mercury release (p < .001) as did RF power (p = .030). At 3T, mercury release was 20.3 times lower than during maturation of dental amalgam, and for the average person an estimated 1.50 ng kg- 1 of mercury might be released during one 3T investigation; this is substantially lower than the tolerable weekly intake of 4,000 ng kg- 1.Conclusion: Mercury release from amalgam shows a measurable increase following MRI, and the magnitude changes with magnetic field strength and RF power. The amount of mercury released is small compared to release during amalgam maturation. Amalgam mercury release during MRI is unlikely to be clinically meaningful and highly likely to remain below safe levels.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] No Increased Mercury Release from Dental Restorations at 1.5T, 3T, or 7T MRI
    Burkett, Brian J.
    Rasmussen, Chad M.
    Fillmore, W. Jonathan
    McDonald, Jennifer S.
    McDonald, Robert J.
    Fagan, Andrew J.
    Erdahl, Sarah A.
    Eckdahl, Steven J.
    Welker, Kirk M.
    MAGNETIC RESONANCE IN MEDICINE, 2024, 91 (02) : 660 - 669
  • [2] Broadband Transmit/Receive Switch for 3T and 7T Magnetic Resonance Imaging
    Abuelhaija, Ashraf
    Saleh, Gameel
    Salama, Sanaa
    Hamdan, Mohammed
    JOURNAL OF ELECTROMAGNETIC ENGINEERING AND SCIENCE, 2024, 24 (03): : 243 - 253
  • [3] MAGNETIC RESONANCE IMAGING OF THE CANINE BRAIN AT 3 AND 7T
    Martin-Vaquero, Paula
    da Costa, Ronaldo C.
    Echandi, Rita L.
    Tosti, Christina L.
    Knopp, Michael V.
    Sammet, Steffen
    VETERINARY RADIOLOGY & ULTRASOUND, 2011, 52 (01) : 25 - 32
  • [4] Visualization of the Amygdalo-Hippocampal Border and its Structural Variability by 7T and 3T Magnetic Resonance Imaging
    Derix, Johanna
    Yang, Shan
    Luesebrink, Falk
    Fiederer, Lukas Dominique Josef
    Schulze-Bonhage, Andreas
    Aertsen, Ad
    Speck, Oliver
    Ball, Tonio
    HUMAN BRAIN MAPPING, 2014, 35 (09) : 4316 - 4329
  • [5] 7T versus 3T phosphorous magnetic resonance spectroscopy in patients with dilated cardiomyopathy
    Victoria Stoll
    William T Clarke
    Eylem Levelt
    Saul G Myerson
    Matthew D Robson
    Stefan Neubauer
    Chris Rodgers
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [6] Ultra high field magnetic resonance carotid vessel wall imaging: comparison between 7T and 3T
    Kroner, E. S. J.
    Versluis, M. J.
    Brouwer, N. J.
    Van der Wall, E. E.
    De Roos, A.
    Webb, A. G.
    Siebelink, H. J.
    Lamb, H. J.
    EUROPEAN HEART JOURNAL, 2012, 33 : 257 - 258
  • [7] 7T MRI Synthesization from 3T Acquisitions
    Cui, Qiming
    Tosun, Duygu
    Mukherjee, Pratik
    Abbasi-Asl, Reza
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2024, PT VII, 2024, 15007 : 35 - 44
  • [8] Lateral geniculate nucleus volumetry at 3T and 7T: Four different optimized magnetic-resonance-imaging sequences evaluated against a 7T reference acquisition
    Aldusary, Njoud
    Michels, Lars
    Traber, Ghislaine Lieselotte
    Hartog-Keisker, Birgit
    Wyss, Michael
    Baeshen, Arwa
    Huebel, Karen
    Almalki, Yassir Edrees
    Brunner, David Otto
    Pruessmann, Klaas Paul
    Landau, Klara
    Kollias, Spyridon
    Piccirelli, Marco
    NEUROIMAGE, 2019, 186 : 399 - 409
  • [9] Microaneurysm Diagnosed With 7T Magnetic Resonance Imaging
    Wang, Linlin
    Zhang, Yingkui
    Sui, Binbin
    Zhao, Xingquan
    Ji, Ruijun
    STROKE, 2022, 53 (06) : E224 - E225
  • [10] Influence of adaptive denoising on Diffusion Kurtosis Imaging at 3T and 7T
    Tro, Rosella
    Roascio, Monica
    Arnulfo, Gabriele
    Tortora, Domenico
    Severino, Mariasavina
    Rossi, Andrea
    Napolitano, Antonio
    Fato, Marco M.
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2023, 234