In Situ Mg/Ca Measurements on Foraminifera: Comparison Between Laser Ablation Inductively Coupled Plasma Mass Spectrometry and Wavelength-Dispersive X-Ray Spectroscopy by Electron Probe Microanalyzer

被引:6
|
作者
Balestra, B. [1 ,2 ,3 ]
Rose, T. [4 ]
Fehrenbacher, J. [5 ]
Knobelspiesse, K. D. [6 ]
Huber, B. T. [2 ]
Gooding, T. [4 ]
Paytan, A. [3 ]
机构
[1] Amer Univ, Environm Sci Dept, Washington, DC 20016 USA
[2] Natl Museum Nat Hist, Dept Paleobiol, MRC 121, Washington, DC 20560 USA
[3] Univ Calif Santa Cruz, Inst Marine Sci, Santa Cruz, CA 95064 USA
[4] Natl Museum Nat Hist, Dept Mineral Sci, Washington, DC 20560 USA
[5] Oregon State Univ, Coll Earth Ocean & Atmospher Sci, Corvallis, OR 97331 USA
[6] NASA, Goddard Space Flight Ctr, Ocean Ecol Lab, Greenbelt, MD USA
关键词
EPMA; foraminifera; LA‐ ICP‐ MS; Mg; Ca; paired analysis; NEOGLOBOQUADRINA-DUTERTREI; PLANKTONIC-FORAMINIFERA; BENTHIC FORAMINIFERA; TRACE-ELEMENTS; VARIABILITY; CALCITE; TEMPERATURE; DELTA-O-18; DELTA-C-13; CHEMISTRY;
D O I
10.1029/2020GC009449
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
We present a comparison of two different techniques: Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS) and wavelength-dispersive X-Ray Spectroscopy by electron probe microanalyzer (EPMA) for obtaining Mg/Ca ratios in individual foraminifera shells. The goal is to assess the use of EPMA as an alternative technique for Mg/Ca analyses of single foraminiferal calcite shells. Foraminifera obtained from sediments (benthic, Uvigerina spp.) and from plankton tows (planktonic, Orbulina universa) were analyzed. All specimens were prepared in epoxy mounts and exposed in cross-section such that multiple high-resolution analyses could be completed on the shells using both techniques. We examined our data using statistical methods designed for the assessment and comparison of measurement techniques. In the case of Uvigerina, the mean difference for ratios obtained using EPMA and LA-ICP-MS is very small (-0.046 mmol mol(-1)) and scale independent. The Limits of Agreement (LoA, the standard deviation of the bias plus the mean bias) is [-0.315, 0.223] mmol mol(-1). For samples with ratios lower than 13 mmol mol(-1), we found a mean EPMA-LA-ICP-MS bias of -2.44 mmol mol(-1) and a corresponding LoA of [-3.85, -1.04] mmol mol(-1). For ratios higher than 13 mmol mol(-1), there appears to be a scale dependent bias, meaning that the EPMA measured ratios become progressively larger than those of LA-ICP-MS as the Mg/Ca ratio increases, so the mean bias and LoA metrics are not meaningful. Results indicate that it is possible to use EPMA to collect Mg/Ca data, if the ratios are lower than similar to 13 mmol mol(-1).
引用
收藏
页码:1 / 10
页数:10
相关论文
共 50 条
  • [21] Apatite chemical composition, determined by electron microprobe and laser-ablation inductively coupled plasma mass spectrometry, as a probe into granite petrogenesis
    Sha, LK
    Chappell, BW
    GEOCHIMICA ET COSMOCHIMICA ACTA, 1999, 63 (22) : 3861 - 3881
  • [22] Validation of K x-ray fluorescence bone lead measurements by inductively coupled plasma mass spectrometry in cadaver legs
    Aro, A
    Amarasiriwardena, C
    Lee, ML
    Kim, R
    Hu, H
    MEDICAL PHYSICS, 2000, 27 (01) : 119 - 123
  • [23] Comparison between X-ray fluorescence and inductively coupled plasma atomic emission spectrometry in the analysis of sediment samples
    Somogyi, A
    Braun, M
    Posta, J
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (13) : 2011 - 2017
  • [24] In situ Mg isotope measurements of biogenic carbonates using laser ablation multi-collector inductively coupled plasma mass spectrometry: A new tool to understand biomineralisation
    Sadekov, Aleksey
    Lloyd, Nicholas S.
    Misra, Sambuddha
    D'Olivo, Juan Pablo
    McCulloch, Malcolm
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2020, 34 (23)
  • [25] An interlaboratory comparison of bone lead measurements via K-shell X-ray fluorescence spectrometry: validation against inductively coupled plasma mass spectrometry
    Bellis, David J.
    Todd, Andrew C.
    Parsons, Patrick J.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2012, 27 (04) : 595 - 603
  • [26] A New Sample Fusion Technique for Quantitative Analysis of Major and Minor Elements in Sulfides with X-Ray Fluorescence Spectrometry and Laser Ablation Inductively Coupled Plasma Mass Spectrometry
    Xu Juan
    Yang Shou-ye
    Hu Zhao-chu
    Luo Tao
    Huang Xiang-tong
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36 (11) : 3683 - 3688
  • [27] Characterization of cobalt pigments found in traditional Valencian ceramics by means of laser ablation-inductively coupled plasma mass spectrometry and portable X-ray fluorescence spectrometry
    Perez-Arantegui, J.
    Resano, M.
    Garcia-Ruiz, E.
    Vanhaecke, F.
    Roldan, C.
    Ferrero, J.
    Coll, J.
    TALANTA, 2008, 74 (05) : 1271 - 1280
  • [28] Preliminary in situ teeth study of the narrow-ridged finless porpoises remains using microsynchrotron radiation X-ray fluorescence and laser ablation inductively coupled plasma mass spectrometry
    Zheng, Yi
    Zhang, Ya
    Tang, Wenqiao
    Guo, Hongyi
    Zhu, Yan
    Dong, Zhaohui
    Jiang, Hui
    X-RAY SPECTROMETRY, 2018, 47 (05) : 388 - 395
  • [29] In situ Analysis of Mg Isotopic Compositions of Basalt Glasses by Femtosecond Laser Ablation Multi-collector Inductively Coupled Plasma Mass Spectrometry
    Dai Meng-Ning
    Bao Zhi-An
    Chen Kai-Yun
    Yuan Hong-Lin
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 44 (02) : 173 - 177
  • [30] Evaluation of the Forensic Utility of Scanning Electron Microscopy-Energy Dispersive Spectroscopy and Laser Ablation-Inductively Coupled Plasma-Mass Spectrometry for Printing Ink Examinations
    Corzo, Ruthmara
    Subedi, Kiran
    Trejos, Tatiana
    Almirall, Jose R.
    JOURNAL OF FORENSIC SCIENCES, 2016, 61 (03) : 725 - 734