Influence of COD:N:P ratio on nitrogen and phosphorus removal in fixed-bed filter

被引:23
|
作者
Tay, JH [1 ]
Chui, PC [1 ]
Li, HH [1 ]
机构
[1] Nanyang Technol Univ, Sch Civil & Environm Engn, Div Environm & Water Resources Engn, Singapore 639798, Singapore
关键词
phosphorus; abatement and removal; filters; nitrification; denitrification;
D O I
10.1061/(ASCE)0733-9372(2003)129:4(285)
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study examined the effects of COD:N:P ratio on nitrogen and phosphorus removal in a single upflow fixed-bed filter provided with anaerobic, anoxic, and aerobic conditions through effluent and sludge recirculation and diffused air aeration. A high-strength wastewater mainly made of peptone, ammonium chloride, monopotassium phosphate, and sodium bicarbonate with varying COD, N, and P concentrations (COD: 2,500-6,000, N: 25-100, and P: 20-50 mg/L) Was used as a substrate feed. Sodium acetate provided about 1,500 mg/L of the wastewater COD while the remainder was provided by glucose and peptone. A series of orthogonal tests using three factors, namely, COD, N, and P concentrations, at three different concentration levels were carried out. The experimental results obtained revealed that phosphorus removal efficiency was affected more by its own concentration than that of COD and N concentrations; while nitrogen removal efficiency was unaffected by different phosphorus concentrations. At a COD:N:P ratio of 300:5: 1, both nitrogen and phosphorus were effectively removed using the filter, with removal efficiencies at 87 and 76%, respectively, under volumetric loadings of 0.1 kgN/m(3) d and 0.02 kg P/m(3) d.
引用
收藏
页码:285 / 290
页数:6
相关论文
共 50 条
  • [21] FIXED-BED ADSORPTION FOR THE REMOVAL OF POLLUTANTS FROM WATER
    MCKAY, G
    BINO, MJ
    ENVIRONMENTAL POLLUTION, 1990, 66 (01) : 33 - 53
  • [22] Modeling hydraulic characteristics and nitrogen removal in a fixed-bed reactor for septic tank effluent treatment
    Zhang, TC
    ENVIRONMENTAL ENGINEERING SCIENCE, 2003, 20 (04) : 347 - 360
  • [23] Influence of COD/ammonia ratio on simultaneous removal of NH4+-N and COD in surface water using moving bed batch reactor
    Yadu, Aparna
    Sahariah, B. P.
    Anandkumar, J.
    JOURNAL OF WATER PROCESS ENGINEERING, 2018, 22 : 66 - 72
  • [24] Advanced nitrogen removal in a fixed-bed anaerobic ammonia oxidation reactor following an anoxic/oxic reactor: Nitrogen removal contributions and mechanisms
    Sui, Qianwen
    Di, Fei
    Zhang, Junya
    Gong, Hui
    Jiang, Li'an
    Wei, Yuansong
    Liu, Jie
    Lin, Jia
    BIORESOURCE TECHNOLOGY, 2021, 320
  • [25] THE RATIO OF FLUIDS TO SOLID TEMPERATURE AND OR CONCENTRATION IN FIXED-BED PROCESSES
    HOELSCHER, HE
    AICHE JOURNAL, 1959, 5 (03) : 410 - 410
  • [26] Influence of N/P ratio on competitive abilities for nitrogen and phosphorus by Microcystis aeruginosa and Aulacoseira distans
    Marcelo Manzi Marinho
    Sandra Maria Feliciano de Oliveira e Azevedo
    Aquatic Ecology, 2007, 41 : 525 - 533
  • [27] Influence of N/P ratio on competitive abilities for nitrogen and phosphorus by Microcystis aeruginosa and Aulacoseira distans
    Marinho, Marcelo Manzi
    de Oliveira e Azevedo, Sandra Maria Feliciano
    AQUATIC ECOLOGY, 2007, 41 (04) : 525 - 533
  • [28] EFFECT OF THE ORGANIC VOLUMETRIC LOADING RATE ON SOLUBLE COD REMOVAL IN DOWN-FLOW ANAEROBIC FIXED-BED REACTORS
    SANCHEZ, EP
    WEILAND, P
    TRAVIESO, L
    BIORESOURCE TECHNOLOGY, 1994, 47 (02) : 173 - 176
  • [29] Analysis of COD, N and P in denitrifying phosphorus removal under multivariate condition
    Wang, Cong
    Wang, Shuying
    Zhang, Miao
    Peng, Yongzhen
    Zeng, Wei
    Huagong Xuebao/CIESC Journal, 2015, 66 (04): : 1467 - 1475
  • [30] THE RATIO OF FLUIDS TO SOLID TEMPERATURE AND OR CONCENTRATION IN FIXED-BED PROCESSES
    KLINKENBERG, A
    AICHE JOURNAL, 1961, 7 (01) : 176 - 176