Minimally invasive and computer-navigated total hip arthroplasty: a qualitative and systematic review of the literature

被引:50
|
作者
Reininga, Inge H. F. [1 ]
Zijlstra, Wiebren [2 ]
Wagenmakers, Robert [1 ]
Boerboom, Alexander L. [1 ]
Huijbers, Bregtje P. [2 ]
Groothoff, Johan W. [3 ]
Bulstra, Sjoerd K. [1 ]
Stevens, Martin [1 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Orthopaed, NL-9700 AB Groningen, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, Ctr Human Movement Sci, NL-9700 AB Groningen, Netherlands
[3] Univ Groningen, Univ Med Ctr Groningen, Dept Hlth Sci, NL-9700 AB Groningen, Netherlands
关键词
ASSISTED ORTHOPEDIC-SURGERY; INCISION TECHNIQUE; ACETABULAR COMPONENT; IMAGELESS NAVIGATION; STANDARD INCISION; MINI-INCISION; REPLACEMENT; POSTERIOR; RESPONSIVENESS; ACCURACY;
D O I
10.1186/1471-2474-11-92
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Both minimally invasive surgery (MIS) and computer-assisted surgery (CAS) for total hip arthroplasty (THA) have gained popularity in recent years. We conducted a qualitative and systematic review to assess the effectiveness of MIS, CAS and computer-assisted MIS for THA. Methods: An extensive computerised literature search of PubMed, Medline, Embase and OVIDSP was conducted. Both randomised clinical trials and controlled clinical trials on the effectiveness of MIS, CAS and computer-assisted MIS for THA were included. Methodological quality was independently assessed by two reviewers. Effect estimates were calculated and a best-evidence synthesis was performed. Results: Four high-quality and 14 medium-quality studies with MIS THA as study contrast, and three high-quality and four medium-quality studies with CAS THA as study contrast were included. No studies with computer-assisted MIS for THA as study contrast were identified. Strong evidence was found for a decrease in operative time and intraoperative blood loss for MIS THA, with no difference in complication rates and risk for acetabular outliers. Strong evidence exists that there is no difference in physical functioning, measured either by questionnaires or by gait analysis. Moderate evidence was found for a shorter length of hospital stay after MIS THA. Conflicting evidence was found for a positive effect of MIS THA on pain in the early postoperative period, but that effect diminished after three months postoperatively. Strong evidence was found for an increase in operative time for CAS THA, and limited evidence was found for a decrease in intraoperative blood loss. Furthermore, strong evidence was found for no difference in complication rates, as well as for a significantly lower risk for acetabular outliers. Conclusions: The results indicate that MIS THA is a safe surgical procedure, without increases in operative time, blood loss, operative complication rates and component malposition rates. However, the beneficial effect of MIS THA on functional recovery has to be proven. The results also indicate that CAS THA, though resulting in an increase in operative time, may have a positive effect on operative blood loss and operative complication rates. More importantly, the use of CAS results in better positioning of acetabular component of the prosthesis.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Minimally invasive hip arthroplasty: a quantitative review of the literature
    Mahmood, Ansar
    Zafar, Mohammed S.
    Majid, Ibrar
    Maffulli, Nicola
    Thompson, John
    BRITISH MEDICAL BULLETIN, 2007, 84 : 37 - 48
  • [32] The limits of precision in conventionally instrumented computer-navigated total knee arthroplasty
    R. E. da Assunção
    N. J. Hancock
    W. J. M. Bruce
    P. Walker
    Knee Surgery, Sports Traumatology, Arthroscopy, 2012, 20 : 2528 - 2534
  • [33] No difference in clinical outcomes in robotic-assisted vs. computer-navigated total hip arthroplasty
    Haroun Haque
    Ameer Tabbaa
    Matthew Johnson
    Lydia Fu
    Afshin Razi
    Matthew L. Magruder
    Arthroplasty, 7 (1)
  • [34] The limits of precision in conventionally instrumented computer-navigated total knee arthroplasty
    da Assuncao, R. E.
    Hancock, N. J.
    Bruce, W. J. M.
    Walker, P.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2012, 20 (12) : 2528 - 2534
  • [35] Evidence-based computer-navigated total hip arthroplasty: An updated analysis of randomized controlled trials
    Li Y.-L.
    Jia J.
    Wu Q.
    Ning G.-Z.
    Wu Q.-L.
    Feng S.-Q.
    European Journal of Orthopaedic Surgery & Traumatology, 2014, 24 (4) : 531 - 538
  • [36] Clinical outcomes associated with robotic and computer-navigated total knee arthroplasty: a machine learning-augmented systematic review
    Quinlan D. Buchlak
    Joe Clair
    Nazanin Esmaili
    Arshad Barmare
    Siva Chandrasekaran
    European Journal of Orthopaedic Surgery & Traumatology, 2022, 32 : 915 - 931
  • [37] Clinical outcomes associated with robotic and computer-navigated total knee arthroplasty: a machine learning-augmented systematic review
    Buchlak, Quinlan D.
    Clair, Joe
    Esmaili, Nazanin
    Barmare, Arshad
    Chandrasekaran, Siva
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2022, 32 (05): : 915 - 931
  • [38] Minimally invasive total hip arthroplasty
    Klein, GR
    Parvizi, J
    Sharkey, PF
    Rothman, RH
    Hozack, WJ
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (441) : 68 - 70
  • [39] Minimally invasive total hip arthroplasty
    Sandiford, Nemandra
    Kabir, Chindu
    Muirhead-Allwood, S. K.
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2008, 90 (05) : 441 - 441
  • [40] Minimally invasive Total hip arthroplasty
    Berry, DJ
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (04): : 699 - 700