Design and performance of a dark-field probe with confocal Raman spectroscopy for ophthalmic applications

被引:3
|
作者
Zhang, Shuo [1 ]
Erckens, Roel J. [1 ]
Jongsma, Franciscus H. M. [1 ]
Webers, Carroll A. B. [1 ]
Berendschot, Tos T. J. M. [1 ]
机构
[1] Maastricht Univ, Univ Eye Clin Maastricht, POB 5800, NL-6202 AZ Maastricht, Netherlands
关键词
aqueous humor; dark‐ field illumination; ocular drug; Raman spectroscopy;
D O I
10.1002/jrs.6125
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A dark-field ophthalmic contact probe for analysis of aqueous humor (AH) was designed by ray tracing and constructed in quartz glass for experimental use as a prototype probe in a confocal Raman spectroscopic setup. The misalignment tolerance of this probe was theoretically evaluated, whereas the optical performance was experimentally evaluated by a concentration curve of the ocular drug phenylephrine HCl in an artificial eye model. The results indicated a ninefold improvement in misalignment tolerance and a 36-fold improvement in the signal-to-noise ratio at the phenylephrine HCl 1002 cm(-1) peak compared with a previous design. The prototype showed a good linear fit with the phenylephrine HCl concentration, with an R-2 of 0.996. Phenylephrine HCl concentration down to 0.1% is detectable.
引用
收藏
页码:1371 / 1375
页数:5
相关论文
共 50 条
  • [31] Confocal Raman spectroscopy -: Applications on wood, pulp, and cellulose fibres
    Röder, T
    Sixta, H
    MACROMOLECULAR SYMPOSIA, 2005, 223 : 57 - 66
  • [32] Dark-Field Microscopy: Recent Advances in Accurate Analysis and Emerging Applications
    Gao, Peng Fei
    Lei, Gang
    Huang, Cheng Zhi
    ANALYTICAL CHEMISTRY, 2021, 93 (11) : 4707 - 4726
  • [33] Laser Dark-Field Illumination System Modeling for Semiconductor Inspection Applications
    Zhou, Wei
    Hart, Darcy
    Roy, Rajiv
    ILLUMINATION OPTICS II, 2011, 8170
  • [34] Virtual double-slit differential dark-field chromatic line confocal imaging technology
    Wang, Shuai
    Liu, Xiaojun
    OPTICS LETTERS, 2023, 48 (04) : 904 - 907
  • [35] Effect of half-stop lateral misalignment on imaging of dark-field and stereoscopic confocal microscopes
    Torok, P
    Laczik, Z
    Sheppard, CJR
    APPLIED OPTICS, 1996, 35 (34): : 6732 - 6739
  • [36] Intrinsic heating in optically trapped Au nanoparticles measured by dark-field spectroscopy
    Andres-Arroyo, Ana
    Wang, Fan
    Toe, Wen Jun
    Reece, Peter
    BIOMEDICAL OPTICS EXPRESS, 2015, 6 (09): : 3646 - 3654
  • [37] A Dark-field Scanning Spectroscopy Platform for Localized Scatter and Fluorescence Imaging of Tissue
    Krishnaswamy, Venkataramanan
    Laughney, Ashley M.
    Paulsen, Keith D.
    Pogue, Brian W.
    BIOMEDICAL APPLICATIONS OF LIGHT SCATTERING V, 2011, 7907
  • [38] A Portable Ultrawideband Confocal Raman Spectroscopy System with a Handheld Probe for Skin Studies
    Zhang, Ruochong
    Bi, Renzhe
    Hui, Chris Ho Jun
    Rajarahm, Poongkulali
    Dinish, U. S.
    Olivo, Malini
    ACS SENSORS, 2021, 6 (08) : 2960 - 2966
  • [39] System Design for Dark-Field Detection of Nanoparticles on Wafer Metal Surface
    Quan, Deng
    Zhao, Zeyu
    He, Lin
    Ling, Liu
    Li, Xiachuqin
    Yang, Gensen
    Xiangang, Luo
    CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2023, 50 (22):
  • [40] Rare Events in Remote Dark-Field Spectroscopy: An Ecological Case Study of Insects
    Runemark, Anna
    Wellenreuther, Maren
    Jayaweera, Hiran H. E.
    Svanberg, Sune
    Brydegaard, Mikkel
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2012, 18 (05) : 1573 - 1582