Three-dimensional intrafractional internal target motions in accelerated partial breast irradiation using three-dimensional conformal external beam radiotherapy

被引:15
|
作者
Hirata, Kimiko [1 ]
Yoshimura, Michio [1 ]
Mukumoto, Nobutaka [1 ]
Nakamura, Mitsuhiro [1 ]
Inoue, Minoru [1 ]
Sasaki, Makoto [2 ]
Fujimoto, Takahiro [2 ]
Yano, Shinsuke [2 ]
Nakata, Manabu [2 ]
Mizowaki, Takashi [1 ]
Hiraoka, Masahiro [1 ]
机构
[1] Kyoto Univ, Grad Sch Med, Dept Radiat Oncol & Image Appl Therapy, Kyoto, Japan
[2] Kyoto Univ Hosp, Clin Radiol Serv Div, Kyoto, Japan
基金
日本学术振兴会;
关键词
Accelerated partial breast irradiation; Baseline drift; Intrafractional motion; Respiratory-induced motion; IMAGE-GUIDED RADIOTHERAPY; RADIATION-THERAPY; RESPIRATORY MOTION; ACCURACY; GUIDANCE; SETUP;
D O I
10.1016/j.radonc.2017.04.023
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: We evaluated three-dimensional intrafractional target motion, divided into respiratory-induced motion and baseline drift, in accelerated partial breast irradiation (APBI). Methods: Paired fluoroscopic images were acquired simultaneously using orthogonal kV X-ray imaging systems at pre- and post-treatment for 23 patients who underwent APBI with external beam radiotherapy. The internal target motion was calculated from the surgical clips placed around the tumour cavity. Results: The peak-to-peak respiratory-induced motions ranged from 0.6 to 1.5 mm in all directions. A systematic baseline drift of 1.5 mm towards the posterior direction and a random baseline drift of 0.3 mm in the lateral-medial and cranial-caudal directions were observed. The baseline for an outer tumour cavity drifted towards the lateral and posterior directions, and that for an upper tumour cavity drifted towards the cranial direction. Moderate correlations were observed between the posterior baseline drift and the patients' physical characteristics. The posterior margin for intrafractional uncertainties was larger than 5 mm in patients with greater fat thickness due to the baseline drift. Conclusions: The magnitude of the intrafractional motion was not uniform according to the direction, patients' physical characteristics, or tumour cavity location due to the baseline drift. Therefore, the intrafractional systematic movement should be properly managed. (C) 2017 Elsevier B.V. All rights reserved.
引用
下载
收藏
页码:118 / 123
页数:6
相关论文
共 50 条
  • [21] Three-Dimensional Conformal External Beam Accelerated Partial Breast Irradiation (3D-APBI): Results of a Phase I Dose Escalation Study
    Taghian, A. G.
    Ancukiewicz, M.
    Smith, B.
    MacDonald, S.
    Specht, M.
    Levy, A.
    Hirsch, A.
    Kachnic, L.
    Powell, S.
    Recht, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S86 - S87
  • [22] Clinical application of three-dimensional conformal partial breast external-beam irradiation after breast-conserving surgery in China
    Li, J. B.
    Fan, T.
    Lu, J.
    Ma, Z.
    JOURNAL OF CLINICAL ONCOLOGY, 2008, 26 (15)
  • [23] SURGICAL CLIPS ASSIST IN THE VISUALIZATION OF THE LUMPECTOMY CAVITY IN THREE-DIMENSIONAL CONFORMAL ACCELERATED PARTIAL-BREAST IRRADIATION
    Dzhugashvili, Maia
    Pichenot, Charlotte
    Dunant, Ariane
    Balleyguier, Corinne
    Delaloge, Suzette
    Mathieu, Marie-Christine
    Garbay, Jean-Remy
    Marsiglia, Hugo
    Bourgier, Celine
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (05): : 1320 - 1324
  • [24] A Comparison of Three-dimensional Conformal Proton Radiotherapy, Three-Dimensional Conformal Photon Radiotherapy and Intensity Modulated Radiotherapy for Retroperitoneal Sarcomas
    Swanson, E. L.
    Slopsema, R.
    Louis, D.
    Paryani, N.
    Morris, C. G.
    Indelicato, D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S612 - S612
  • [25] Pulmonary Toxicity Following Accelerated Partial-Breast Irradiation Using Three-Dimensional Conformal Radiation Therapy for Breast Conserving Therapy
    Shikama, N.
    Kumazaki, Y.
    Miyaura, K.
    Kato, S.
    Kawamori, J.
    Nakamura, N.
    Shimizuguchi, T.
    Saito, N.
    Oosaki, A.
    Saeki, T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E7 - E7
  • [26] Lung Dose-Volume Parameters and the Risk of Pneumonitis for Patients Treated With Accelerated Partial-Breast Irradiation Using Three-Dimensional Conformal Radiotherapy
    Recht, Abram
    Ancukiewicz, Marek
    El-Din, Mohamed A. Alm
    Lu, Xing-Qi
    Martin, Chrystalla
    Berman, Stuart M.
    Hirsch, Ariel E.
    Kachnic, Lisa A.
    Katz, Angela
    MacDonald, Shannon
    Nedea, Elena A.
    Stevenson, Mary Ann
    Powell, Simon N.
    Taghian, Alphonse G.
    JOURNAL OF CLINICAL ONCOLOGY, 2009, 27 (24) : 3887 - 3893
  • [27] A comparison of dosimetric variance for external-beam partial breast irradiation using three-dimensional and four-dimensional computed tomography
    Guo, Bing
    Li, Jian-Bin
    Wang, Wei
    Xu, Min
    Li, Yan-Kang
    Liu, Tong-Hai
    ONCOTARGETS AND THERAPY, 2016, 9 : 1857 - 1863
  • [28] Dosimetric comparison of four different external beam partial breast irradiation techniques: Three-dimensional conformal radiotherapy, intensity-modulated radiotherapy, helical tomotherapy, and proton beam therapy
    Moon, Sung Ho
    Shin, Kyung Hwan
    Kim, Tae Hyun
    Yoon, Myonggeun
    Park, Soah
    Lee, Doo-Hyun
    Kim, Jong Won
    Kim, Dae Woong
    Park, Sung Yong
    Cho, Kwan Ho
    RADIOTHERAPY AND ONCOLOGY, 2009, 90 (01) : 66 - 73
  • [29] Three-dimensional conformal radiotherapy for esophageal carcinoma
    Wang, L.
    Han, C.
    Chi, Z.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S470 - S470
  • [30] DOES THREE-DIMENSIONAL EXTERNAL BEAM PARTIAL BREAST IRRADIATION SPARE LUNG TISSUE COMPARED WITH STANDARD WHOLE BREAST IRRADIATION?
    Jain, Anudh K.
    Vallow, Laura A.
    Gale, Ashley A.
    Buskirk, Steven J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (01): : 82 - 88