Three-dimensional intrafractional internal target motions in accelerated partial breast irradiation using three-dimensional conformal external beam radiotherapy

被引:15
|
作者
Hirata, Kimiko [1 ]
Yoshimura, Michio [1 ]
Mukumoto, Nobutaka [1 ]
Nakamura, Mitsuhiro [1 ]
Inoue, Minoru [1 ]
Sasaki, Makoto [2 ]
Fujimoto, Takahiro [2 ]
Yano, Shinsuke [2 ]
Nakata, Manabu [2 ]
Mizowaki, Takashi [1 ]
Hiraoka, Masahiro [1 ]
机构
[1] Kyoto Univ, Grad Sch Med, Dept Radiat Oncol & Image Appl Therapy, Kyoto, Japan
[2] Kyoto Univ Hosp, Clin Radiol Serv Div, Kyoto, Japan
基金
日本学术振兴会;
关键词
Accelerated partial breast irradiation; Baseline drift; Intrafractional motion; Respiratory-induced motion; IMAGE-GUIDED RADIOTHERAPY; RADIATION-THERAPY; RESPIRATORY MOTION; ACCURACY; GUIDANCE; SETUP;
D O I
10.1016/j.radonc.2017.04.023
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: We evaluated three-dimensional intrafractional target motion, divided into respiratory-induced motion and baseline drift, in accelerated partial breast irradiation (APBI). Methods: Paired fluoroscopic images were acquired simultaneously using orthogonal kV X-ray imaging systems at pre- and post-treatment for 23 patients who underwent APBI with external beam radiotherapy. The internal target motion was calculated from the surgical clips placed around the tumour cavity. Results: The peak-to-peak respiratory-induced motions ranged from 0.6 to 1.5 mm in all directions. A systematic baseline drift of 1.5 mm towards the posterior direction and a random baseline drift of 0.3 mm in the lateral-medial and cranial-caudal directions were observed. The baseline for an outer tumour cavity drifted towards the lateral and posterior directions, and that for an upper tumour cavity drifted towards the cranial direction. Moderate correlations were observed between the posterior baseline drift and the patients' physical characteristics. The posterior margin for intrafractional uncertainties was larger than 5 mm in patients with greater fat thickness due to the baseline drift. Conclusions: The magnitude of the intrafractional motion was not uniform according to the direction, patients' physical characteristics, or tumour cavity location due to the baseline drift. Therefore, the intrafractional systematic movement should be properly managed. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:118 / 123
页数:6
相关论文
共 50 条
  • [1] Three-Dimensional Conformal External Beam Accelerated Partial Breast Irradiation
    Ognibene, G.
    Horst, K. C.
    Fasola, C. E.
    Goffinet, D. R.
    Dirbas, F. M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S274 - S274
  • [2] TOXICITY OF THREE-DIMENSIONAL CONFORMAL RADIOTHERAPY FOR ACCELERATED PARTIAL BREAST IRRADIATION
    Hepel, Jaroslaw T.
    Tokita, Mari
    MacAusland, Stephanie G.
    Evans, Suzanne B.
    Hiatt, Jessica R.
    Price, Lori Lyn
    DiPetrillo, Thomas
    Wazer, David E.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (05): : 1290 - 1296
  • [3] PREDICTORS OF LONG-TERM TOXICITY USING THREE-DIMENSIONAL CONFORMAL EXTERNAL BEAM RADIOTHERAPY TO DELIVER ACCELERATED PARTIAL BREAST IRRADIATION
    Shaitelman, Simona F.
    Kim, Leonard H.
    Grills, Inga S.
    Chen, Peter Y.
    Chen, Hong Y.
    Ye, Hong
    Kestin, Larry L.
    Yan, Di
    Vicini, Frank A.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (03): : 788 - 794
  • [4] Identifying Patients Who Are Unsuitable for Accelerated Partial Breast Irradiation Using Three-Dimensional External Beam Conformal Techniques
    Shikama, Naoto
    Nakamura, Naoki
    Kunishima, Naoaki
    Hatanaka, Shogo
    Sekiguchi, Kenji
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (03): : E313 - E318
  • [5] Accelerated partial breast irradiation using robotic radiotherapy: a dosimetric comparison with tomotherapy and three-dimensional conformal radiotherapy
    Erwann Rault
    Thomas Lacornerie
    Hong-Phuong Dang
    Frederik Crop
    Eric Lartigau
    Nick Reynaert
    David Pasquier
    [J]. Radiation Oncology, 11
  • [6] Accelerated partial breast irradiation using robotic radiotherapy: a dosimetric comparison with tomotherapy and three-dimensional conformal radiotherapy
    Rault, Erwann
    Lacornerie, Thomas
    Hong-Phuong Dang
    Crop, Frederik
    Lartigau, Eric
    Reynaert, Nick
    Pasquier, David
    [J]. RADIATION ONCOLOGY, 2016, 11
  • [7] Symptomatic Radiation Pneumonitis After Accelerated Partial Breast Irradiation Using Three-dimensional Conformal Radiotherapy
    Shikama, Naoto
    Kumazaki, Yu
    Miyazawa, Kazunari
    Miyaura, Kazunori
    Kato, Shingo
    Nakamura, Naoki
    Kawamori, Jiro
    Shimizuguchi, Takuya
    Saito, Naoko
    Saeki, Toshiaki
    [J]. ANTICANCER RESEARCH, 2016, 36 (05) : 2475 - 2479
  • [8] Dosimetric comparison of two different three-dimensional conformal external beam accelerated partial breast irradiation techniques
    Kozak, Kevin R.
    Doppke, Karen P.
    Katz, Angela
    Taghian, Alphonse G.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (02): : 340 - 346
  • [9] Dosimetric comparison of proton and photon three-dimensional, conformal, external beam accelerated partial breast irradiation techniques
    Kozak, Kevin R.
    Katz, Angela
    Adams, Judith
    Crowley, Elizabeth M.
    Nyamwanda, Jacqueline A.
    Feng, Jennifer K.
    Doppke, Karen P.
    DeLaney, Thomas F.
    Taghian, Alphonse G.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (05): : 1572 - 1578
  • [10] DOSIMETRIC COMPARISON OF THREE-DIMENSIONAL CONFORMAL RADIOTHERAPY AND INTERSTITIAL BRACHYTHERAPY FOR PARTIAL BREAST IRRADIATION, AND WHOLE BREAST EXTERNAL BEAM IRRADIATION
    Major, T.
    Frohlich, G.
    Janvary, L.
    Polgar, C.
    Fodor, J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S443 - S444