A review of artificial contamination withstand test methods of high voltage outdoor insulators

被引:7
|
作者
Naderian, A [1 ]
Sanaye-Pasand, M [1 ]
Mohseni, H [1 ]
机构
[1] Univ Tehran, ECE Dept, Tehran, Iran
关键词
D O I
10.1109/ELINSL.2004.1380559
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper several important test methods for artificially polluted ceramic and non-ceramic insulators have been reviewed. There is no standard test for non-ceramic insulators. The research has shown that it is necessary to modify the standard 5000h salt fog test to evaluate the long-term performance of non-ceramic insulators. Although the main parameter for selection of proper ceramic and glass insulators is the amount of pollution, it seems to be necessary to consider other environmental factors for selection of composite insulators. These are average humidity, UV radiation level, wind velocity, rain fall, and dominant type of wetting. This is necessary because research has shown that they directly effect the performance,of non-ceramic insulators.
引用
收藏
页码:284 / 287
页数:4
相关论文
共 50 条
  • [31] Effects of Artificial Polluting Methods on AC Flashover Voltage of Composite Insulators
    Dong, Bingbing
    Jiang, Xingliang
    Hu, Jianlin
    Shu, Lichun
    Sun, Caixin
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2012, 19 (02) : 714 - 722
  • [32] Effects of algae contamination on the hydrophobicity of high-voltage composite insulators
    Yang, Shifang
    Jia, Zhidong
    Ouyang, Xiaogang
    HIGH VOLTAGE, 2019, 4 (03): : 234 - 240
  • [33] Regression technique for prediction of salt contamination severity on high voltage insulators
    Ahmad, AS
    Ahmad, H
    Salam, A
    Saad, A
    2000 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS. I & II, 2000, : 218 - 221
  • [34] Computer Package for Selecting High Voltage Insulators for Different Contamination Conditions
    Dhahbi-Megriche, N.
    Arfaoui, W.
    Beroual, A.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2013, 20 (04) : 1428 - 1435
  • [35] Factors Improving the Electrical Performance of EPDM Rubber Outdoor High Voltage Insulators
    Nasrat, L. S.
    2009 IEEE ELECTRICAL INSULATION CONFERENCE, 2009, : 82 - 85
  • [36] Pollution Flashover Characteristics of High-Voltage Outdoor Insulators: Analytical Study
    Salem, Ali Ahmed
    Abd Rahman, Rahisham
    Al-Ameri, Salem
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2022, 47 (03) : 2711 - 2729
  • [37] Pollution Flashover Characteristics of High-Voltage Outdoor Insulators: Analytical Study
    Ali Ahmed Salem
    Rahisham Abd Rahman
    Salem Al-Ameri
    Arabian Journal for Science and Engineering, 2022, 47 : 2711 - 2729
  • [38] Estimation of salt contamination level on the high voltage insulators surfaces during rainy season using artificial neural network
    Ahmad, AS
    Ghosh, PS
    Aljunid, SAK
    Ahmad, H
    FIFTH INTERNATIONAL CONFERENCE ON POWER SYSTEM MANAGEMENT AND CONTROL, 2002, (488): : 303 - 308
  • [39] Review of the Performance of High-Voltage Composite Insulators
    Saleem, Muhammad Zaheer
    Akbar, Mohammad
    POLYMERS, 2022, 14 (03)
  • [40] Evaluation methods of contamination flashover voltage performance of semi-conducting glaze insulators
    Hayashi, Akio
    Yamada, Kazuma
    Saka, Chiharu
    Sakanishi, Kenji
    Matsuoka, Ryosuke
    CONFERENCE RECORD OF THE 2008 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, VOLS 1 AND 2, 2008, : 458 - 461