Alumina-on-Alumina Total Hip Arthroplasty A Concise Follow-up, at a Minimum of Ten Years, of a Previous Report

被引:77
|
作者
Lee, Young-Kyun [1 ]
Ha, Yong-Chan [1 ]
Yoo, Jeong Joon [1 ]
Koo, Kyung-Hoi [1 ]
Yoon, Kang Sup [1 ]
Kim, Hee Joong [1 ]
机构
[1] Seoul Natl Univ, Coll Med, Dept Orthopaed Surg, Seoul 110744, South Korea
来源
关键词
RADIOGRAPHIC ANALYSIS; FEMORAL COMPONENTS; REPLACEMENT; ARTHRITIS; FRACTURE; FAILURE; HEAD;
D O I
10.2106/JBJS.I.01019
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We previously reported the five-to-six-year results of the use of third-generation alumina-on-alumina bearings in a consecutive series of 100 primary cementless total hip arthroplasties. This report presents the longer-term outcomes of these same bearings, at a minimum of ten years postoperatively. Eighty-six of eighty-eight hips available for the study retained the original bearings at the time of the latest follow-up. Thirteen hips were associated with noise, and six hips demonstrated fretting of the femoral neck on radiographs. Two hips required a change of the bearings because of a ceramic head fracture. The ten-year survival rate of the alumina-on-alumina total hip prostheses, with revision of any implant for any reason as the end point, was 99.0%. On the basis of those results, we concluded that the rate of survival of primary cementless total hip prostheses with third-generation alumina-on-alumina bearings is excellent at ten years. However, the risk of ceramic fracture, noise, and impingement between the metal neck and the ceramic liner should be a concern to surgeons, and patients should be informed of these risks before surgery.
引用
收藏
页码:1715 / 1719
页数:5
相关论文
共 50 条
  • [1] Excellent results with cementless total hip arthroplasty and alumina-on-alumina pairing: minimum ten-year follow-up
    Alexander M. Kress
    Rainer Schmidt
    Ulrich Holzwarth
    Raimund Forst
    Lutz A. Mueller
    [J]. International Orthopaedics, 2011, 35 : 195 - 200
  • [2] Alumina-on-alumina total hip arthroplasty - A minimum 18.5-year follow-up study
    Hamadouche, M
    Boutin, P
    Daussange, J
    Bolander, ME
    Sedel, L
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (01): : 69 - 77
  • [3] Excellent results with cementless total hip arthroplasty and alumina-on-alumina pairing: minimum ten-year follow-up
    Kress, Alexander M.
    Schmidt, Rainer
    Holzwarth, Ulrich
    Forst, Raimund
    Mueller, Lutz A.
    [J]. INTERNATIONAL ORTHOPAEDICS, 2011, 35 (02) : 195 - 200
  • [4] Alumina-on-alumina total hip arthroplasty - A five-year minimum follow-up study
    Yoo, JJ
    Kim, YM
    Yoon, KS
    Koo, KH
    Song, WS
    Kim, HJ
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (03): : 530 - 535
  • [5] A Minimum Ten Years of Follow-Up of Alumina Head on Delta Liner Total Hip Arthroplasty
    Choy, Won-sik
    Cha, Yong-han
    Jeon, Chung-youb
    Lee, Kyu-sang
    Kim, Ha-yong
    [J]. JOURNAL OF ARTHROPLASTY, 2018, 33 (02): : 470 - 476
  • [6] Results of Charnley total hip arthroplasty at a minimum of thirty years - A concise follow-up of a previous report
    Callaghan, JJ
    Templeton, JE
    Liu, SS
    Pedersen, DR
    Goetz, DD
    Sullivan, PM
    Johnston, RC
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (04): : 690 - 695
  • [7] Cementless alumina-on-alumina total hip arthroplasty in patients younger than 50 years - A 5-year minimum follow-up study
    Ha, Yong-Chan
    Koo, Kyung-Hoi
    Jeong, Soon-Taek
    Yoo, Jeong Joon
    Kim, Young-Min
    Kim, Hee Joong
    [J]. JOURNAL OF ARTHROPLASTY, 2007, 22 (02): : 184 - 188
  • [8] Contemporary alumina-on-alumina total hip arthroplasty performed in patients younger than forty years: A 5-year minimum follow-up study
    Yoo, Jeong Joon
    Kim, Young-Min
    Yoon, Kang Sup
    Koo, Kyung-Hoi
    Kim, Jong Won
    Nam, Kwang Woo
    Kim, Hee Joong
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2006, 78B (01) : 70 - 75
  • [9] Revision total hip arthroplasty performed with a contemporary alumina-on-alumina bearing surface; Minimum 5-year follow-up study
    Yoo, JJ
    Kim, HJ
    Kim, YM
    Yoon, KS
    Koo, KH
    Nam, KW
    Shing, SI
    [J]. BIOCERAMICS 18, PTS 1 AND 2, 2006, 309-311 : 1353 - 1356
  • [10] Thirty years of experience with alumina-on-alumina bearings in total hip arthroplasty
    Didier Hannouche
    Amine Zaoui
    Frédéric Zadegan
    Laurent Sedel
    Rémy Nizard
    [J]. International Orthopaedics, 2011, 35 : 207 - 213