Alumina-on-alumina total hip arthroplasty - A five-year minimum follow-up study

被引:133
|
作者
Yoo, JJ [1 ]
Kim, YM [1 ]
Yoon, KS [1 ]
Koo, KH [1 ]
Song, WS [1 ]
Kim, HJ [1 ]
机构
[1] Seoul Natl Univ, Coll Med, Dept Orthopaed Surg, Seoul, South Korea
来源
关键词
D O I
10.2106/JBJS.D.01753
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Ceramic-on-ceramic couplings are attractive alternative bearing surfaces that have been reported to eliminate or reduce problems related to polyethylene wear debris. Disappointing experiences with alumina ceramic bearings in the past have led to many improvements in the manufacture and design of ceramic implants. The purpose of the present study was to report the results of contemporary alumina-on-alumina total hip arthroplasties with regard to wear, osteolysis, and fracture of the ceramic after a minimum duration of follow-up of five years. Methods: We evaluated the results of a consecutive series of 100 primary alumina-on-alumina total hip arthroplasties that had been performed with use of a metal-backed socket and a cementless stem in eighty-four patients. All of the patients were sixty-five years of age or younger (mean age, forty-one years), and a single surgeon performed all of the procedures. After a minimum duration of follow-up of sixty months, one patient (one hip) had died and four patients (six hips) had been lost to follow-up, leaving a total of seventy-nine patients (ninety-three hips) available for study. All of these patients were evaluated clinically and radiographically with special attention to wear, periprosthetic osteolysis, and ceramic failure. Results: The mean Harris hip score was 97 points at the time of the latest follow-up evaluation. All prostheses demonstrated radiographic evidence of bone ingrowth. No implant was loose radiographically, and no implant was revised. Ceramic wear was not detectable in the thirty-seven hips in which the femoral head could be differentiated from the cup on radiographs. Periprosthetic osteolysis was not observed in any hip. A fracture of the alumina femoral head and a peripheral chip fracture of the alumina insert occurred in one hip following a motor-vehicle accident. Conclusions: The results of contemporary alumina-on-alumina total hip arthroplasty with a metal-backed socket and a cementless stem were encouraging after a minimum duration of follow-up of five years. We believe that these improved alumina-on-alumina bearing implants offer a promising option for younger, active patients.
引用
收藏
页码:530 / 535
页数:6
相关论文
共 50 条
  • [1] Alumina-on-alumina total hip arthroplasty - A minimum 18.5-year follow-up study
    Hamadouche, M
    Boutin, P
    Daussange, J
    Bolander, ME
    Sedel, L
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (01): : 69 - 77
  • [2] Excellent results with cementless total hip arthroplasty and alumina-on-alumina pairing: minimum ten-year follow-up
    Alexander M. Kress
    Rainer Schmidt
    Ulrich Holzwarth
    Raimund Forst
    Lutz A. Mueller
    [J]. International Orthopaedics, 2011, 35 : 195 - 200
  • [3] Excellent results with cementless total hip arthroplasty and alumina-on-alumina pairing: minimum ten-year follow-up
    Kress, Alexander M.
    Schmidt, Rainer
    Holzwarth, Ulrich
    Forst, Raimund
    Mueller, Lutz A.
    [J]. INTERNATIONAL ORTHOPAEDICS, 2011, 35 (02) : 195 - 200
  • [4] Alumina-on-Alumina Total Hip Arthroplasty A Concise Follow-up, at a Minimum of Ten Years, of a Previous Report
    Lee, Young-Kyun
    Ha, Yong-Chan
    Yoo, Jeong Joon
    Koo, Kyung-Hoi
    Yoon, Kang Sup
    Kim, Hee Joong
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (08): : 1715 - 1719
  • [5] Revision total hip arthroplasty performed with a contemporary alumina-on-alumina bearing surface; Minimum 5-year follow-up study
    Yoo, JJ
    Kim, HJ
    Kim, YM
    Yoon, KS
    Koo, KH
    Nam, KW
    Shing, SI
    [J]. BIOCERAMICS 18, PTS 1 AND 2, 2006, 309-311 : 1353 - 1356
  • [6] Cementless alumina-on-alumina total hip arthroplasty in patients younger than 50 years - A 5-year minimum follow-up study
    Ha, Yong-Chan
    Koo, Kyung-Hoi
    Jeong, Soon-Taek
    Yoo, Jeong Joon
    Kim, Young-Min
    Kim, Hee Joong
    [J]. JOURNAL OF ARTHROPLASTY, 2007, 22 (02): : 184 - 188
  • [7] Third-Generation Alumina-on-Alumina Total Hip Arthroplasty: 14 to 16-Year Follow-Up Study
    Kang, Bun-Jung
    Ha, Yong-Chan
    Ham, Dae-Woong
    Hwang, Sun-Chul
    Lee, Young-Kyun
    Koo, Kyung-Hoi
    [J]. JOURNAL OF ARTHROPLASTY, 2015, 30 (03): : 411 - 415
  • [8] Contemporary alumina-on-alumina total hip arthroplasty performed in patients younger than forty years: A 5-year minimum follow-up study
    Yoo, Jeong Joon
    Kim, Young-Min
    Yoon, Kang Sup
    Koo, Kyung-Hoi
    Kim, Jong Won
    Nam, Kwang Woo
    Kim, Hee Joong
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2006, 78B (01) : 70 - 75
  • [9] Failure Analysis of Alumina on Alumina Total Hip Arthroplasty With a Layered Acetabular Component Minimum Ten-Year Follow-Up Study
    Kawano, Shunsuke
    Sonohata, Motoki
    Shimazaki, Takafumi
    Kitajima, Masaru
    Mawatari, Masaaki
    Hotokebuchi, Takao
    [J]. JOURNAL OF ARTHROPLASTY, 2013, 28 (10): : 1822 - 1827
  • [10] The evolution of an uncemented acetabular component in alumina-on-alumina total hip arthroplasty has improved clinical outcome A PROSPECTIVE, COMPARATIVE FIVE- TO 15-YEAR FOLLOW-UP STUDY
    Garcia-Rey, E.
    Cruz-Pardos, A.
    Garcia-Cimbrelo, E.
    [J]. BONE & JOINT JOURNAL, 2017, 99B (06): : 749 - 758