Modular cole phantom for parametric electrical impedance tomography

被引:0
|
作者
Rigaud, B [1 ]
Chauveau, N [1 ]
Ayeva, B [1 ]
Fargues, F [1 ]
Martinez, E [1 ]
Morucci, JP [1 ]
机构
[1] Univ Toulouse 3, Hotel Dieu, Ctr Hosp, INSERM U305, F-31052 Toulouse, France
来源
PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5 | 1997年 / 18卷
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A phantom was designed for studying in vitro acquisition procedures and reconstruction algorithms for multifrequency electrical impedance tomography (EIT). The phantom mimics a circular region discretized in 208 square pixels whose sides are composed of Cole models. A modular design, based on plug-in boards, provides facilities for modifying the electrical parameters of any pixel. This phantom is used especially for studying tissue characterization by imaging the characteristic frequency.
引用
收藏
页码:794 / 795
页数:2
相关论文
共 50 条
  • [41] 16 by 3 Electrodes Electrical Impedance Tomography System Implementation on Cylindrical Phantom Design and Development
    Salam, Abdul A. Haris
    Farha, Nurul Zainuddin
    Najeb, Mohd Jamaludin
    Amir, Muhammad As'ari
    Jaysuman, Pusppanathan
    Fitri, Hadafi Mohd Latip
    2020 IEEE-EMBS CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES 2020): LEADING MODERN HEALTHCARE TECHNOLOGY ENHANCING WELLNESS, 2021, : 560 - 564
  • [42] Simulations and phantom evaluations of magnetic resonance electrical impedance tomography (MREIT) for breast cancer detection
    Sadleir, Rosalind J.
    Sajib, Saurav Z. K.
    Kim, Hyung Joong
    Kwon, Oh In
    Woo, Eung Je
    JOURNAL OF MAGNETIC RESONANCE, 2013, 230 : 40 - 49
  • [43] A chicken tissue phantom for studying an electrical impedance tomography (EIT) system suitable for clinical imaging
    Bera T.K.
    Nagaraju J.
    Sensing and Imaging: An International Journal, 2011, 12 (3-4) : 95 - 116
  • [44] Static resistivity image of a cubic saline phantom in magnetic resonance electrical impedance tomography (MREIT)
    Lee, BI
    Oh, SH
    Woo, EJ
    Lee, SY
    Cho, MH
    Kwon, O
    Seo, JK
    Baek, WS
    PHYSIOLOGICAL MEASUREMENT, 2003, 24 (02) : 579 - 589
  • [45] Multifrequency electrical impedance tomography (Mf-EIT) for the detection of breast cancer phantom anomalies
    Ariwanto, Bayu
    Ain, Khusnul
    Rulaningtyas, Riries
    Ukhrowiyah, Nuril
    Aisya, Rohadatul
    Basori, Ahmad Hoirul
    Mansur, Andi Besse Fidausiah
    METHODSX, 2025, 14
  • [46] Resistivity imaging of a reconfigurable phantom with circular inhomogeneities in 2D-electrical impedance tomography
    Bera, Tushar Kanti
    Nagaraju, Jampana
    MEASUREMENT, 2011, 44 (03) : 518 - 526
  • [47] A Development of electrode probes for imaging precancerous lesions with electrical impedance tomography technique: A phantom study
    Ngamdi N.
    Sriwilai J.
    Trongwongsa T.
    Ouypornkochagorn T.
    Journal of Applied Science and Engineering, 2024, 27 (01): : 1901 - 1910
  • [48] SPICE and MATLAB simulation and evaluation of Electrical Impedance Tomography readout chain using phantom equivalents
    Dimas, Christos
    Alimisis, Vassilis
    Sotiriadis, Paul P.
    24TH IEEE EUROPEAN CONFERENCE ON CIRCUIT THEORY AND DESIGN (ECCTD 2020), 2020,
  • [49] Multi-frequency Electrical Impedance Tomography and Magnetic Resonance Electrical Impedance Tomography
    Seo, Jin Keun
    Woo, Eung Je
    MATHEMATICAL MODELING IN BIOMEDICAL IMAGING I: ELECTRICAL AND ULTRASOUND TOMOGRAPHIES, ANOMALY DETECTION, AND BRAIN IMAGING, 2009, 1983 : 1 - 71
  • [50] Algorithm for the inversion of the Cole-Cole model from the real part of electrical impedance
    Miranda, D. A.
    Barrero, J. G.
    IV LATIN AMERICAN CONGRESS ON BIOMEDICAL ENGINEERING 2007, BIOENGINEERING SOLUTIONS FOR LATIN AMERICA HEALTH, VOLS 1 AND 2, 2008, 18 (1,2): : 578 - 582