Performance characteristics of a gated fiber-optic-coupled dosimeter in high-energy pulsed photon radiation dosimetry

被引:14
|
作者
Tanyi, James A. [1 ,2 ]
Krafft, Shane P. [3 ]
Ushino, Toshihide [4 ]
Huston, Alan L. [5 ]
Justus, Brian L. [5 ]
机构
[1] Oregon Hlth & Sci Univ, Dept Radiat Med, Portland, OR 97239 USA
[2] Oregon State Univ, Dept Nucl Engn & Radiat Hlth Phys, Corvallis, OR 97331 USA
[3] Univ Arizona, Dept Phys, Tucson, AZ 85721 USA
[4] Univ Calif Los Angeles, Off Environm Hlth & Safety, Los Angeles, CA 90095 USA
[5] USN, Res Lab, Div Opt Sci, Washington, DC 20375 USA
关键词
Real-time dosimetry; Pulsed photon beam; Gated fiber-optics; In vivo dosimetry; QUALITY-ASSURANCE; REAL-TIME; DETECTOR; RADIOTHERAPY; LUMINESCENCE; DIODE; BEAMS;
D O I
10.1016/j.apradiso.2009.10.042
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Fiber-optic-coupled dosimeters (FOCDs) are a new class of in vivo dosimetry systems that are finding increased clinical applications. Utility of FOCDs has been limited in dosimetric applications due Cerenkov-ray signal contamination. The current study reports on the characterization of a novel FOCD, with a gated detection system for the discrimination and effective elimination of the direct contribution of Cerenkov radiation, for use in the radiotherapeutic realm. System reproducibility, linearity and output dependence on dose rate, energy, field size, and temperature response were characterized for 6, 10, and 15 MV photon energies. The system exhibited a linear response to absorbed dose ranging from 1 to 2400 cGy and showed little dependence to dose rate variations. Overall system reproducibility was 0.52% with no field-geometry and temperature dependence. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:364 / 369
页数:6
相关论文
共 40 条
  • [31] Implementation and performance of a fiber-coupled CMOS camera in an ultrafast reflective high-energy electron diffraction experiment
    Fortmann, Jonas D.
    Kassen, Alexander
    Brand, Christian
    Duden, Thomas
    Horn-von Hoegen, Michael
    STRUCTURAL DYNAMICS-US, 2025, 12 (02):
  • [32] Development of One-dimensional Fiber-Optic Radiation Sensor for Measuring Dose Distributions of High Energy Photon Beams
    Bongsoo Lee
    Kyoung Won Jang
    Dong Hyun Cho
    Wook Jae Yoo
    Hyung Shik Kim
    Soon-Cheol Chung
    Jeong Han Yi
    Optical Review, 2007, 14 : 351 - 354
  • [33] Development of one-dimensional fiber-optic radiation sensor for measuring dose distributions of high energy photon beams
    Lee, Bongsoo
    Jang, Kyoung Won
    Cho, Dong Hyun
    Yoo, Wook Jae
    Kim, Hyung Shik
    Chung, Soon-Cheol
    Yi, Jeong Han
    OPTICAL REVIEW, 2007, 14 (05) : 351 - 354
  • [34] Elaboration and TL&OSL response study of 1% Sb-doped Al2O3 dosimeter for high-energy radiation detection and dosimetry
    Benkhelifa, Chahra-Zed
    Hamici, Melia
    Kharfi, Faycal
    JOURNAL OF SOL-GEL SCIENCE AND TECHNOLOGY, 2023, 106 (03) : 654 - 662
  • [35] Elaboration and TL&OSL response study of 1% Sb-doped Al2O3 dosimeter for high-energy radiation detection and dosimetry
    Chahra-Zed Benkhelifa
    Melia Hamici
    Faycal Kharfi
    Journal of Sol-Gel Science and Technology, 2023, 106 : 654 - 662
  • [36] Performance Evaluation of One-dimensional Fiber-optic Radiation Sensor for Measuring High Energy Electron Beam Using a Charge-coupled Device
    Cho, Dong Hyun
    Jang, Kyoung Won
    Yoo, Wook Jae
    Chung, Soon Cheol
    Tack, Gye Rae
    Eom, Gwang Moon
    Lee, Bongsoo
    Cho, Hyosung
    Kim, Sin
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2008, : 477 - 480
  • [37] FEASIBILITY AND CONDITIONS OF ATTAINMENT OF HIGH-ENERGY CHARACTERISTICS OF THE RADIATION EMITTED BY A PULSED CHEMICAL HF LASER UTILIZING AN SF6 HI MIXTURE
    GAL, AV
    RUSANOV, VD
    SHIRYAEVSKII, VL
    SHOLIN, GV
    KVANTOVAYA ELEKTRONIKA, 1992, 19 (07): : 641 - 642
  • [38] Thick film SOI technology: characteristics of devices and performance of circuits for high-energy physics at cryogenic temperatures; effects of ionizing radiation
    Fourches, N
    Abbon, P
    Chipaux, R
    Delagnes, E
    Orsier, E
    Pailler, P
    de Pontcharra, JD
    Rouger, M
    Sueur, M
    Truche, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 401 (2-3): : 229 - 237
  • [39] Thick film SOI technology: Characteristics of devices and performance of circuits for high-energy physics at cryogenic temperatures; Effects of ionizing radiation
    C.E. Saclay, Gif-sur-Yvette, France
    Nucl Instrum Methods Phys Res Sect A, 2-3 (229-237):
  • [40] Non-reference condition correction factor kNR of typical radiation detectors applied for the dosimetry of high-energy photon fields in radiotherapy (vol 22, pg 181, 2012)
    Chofor, Ndimofor
    Harder, Dietrich
    Poppe, Bjoern
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2012, 22 (04): : 335 - 335