Calibration of a flexible measurement system based on industrial articulated robot and structured light sensor

被引:19
|
作者
Mu, Nan [1 ]
Wang, Kun [1 ]
Xie, Zexiao [1 ]
Ren, Ping [1 ]
机构
[1] Ocean Univ China, Dept Automat, Engn Coll, Qingdao, Peoples R China
基金
美国国家科学基金会; 中国国家自然科学基金;
关键词
flexible measurement system; industrial robot; structured light; hand-eye calibration; kinematic parameter calibration; distance error model; XB; AX;
D O I
10.1117/1.OE.56.5.054103
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
To realize online rapid measurement for complex workpieces, a flexible measurement system based on an articulated industrial robot with a structured light sensor mounted on the end-effector is developed. A method for calibrating the system parameters is proposed in which the hand-eye transformation parameters and the robot kinematic parameters are synthesized in the calibration process. An initial hand-eye calibration is first performed using a standard sphere as the calibration target. By applying the modified complete and parametrically continuous method, we establish a synthesized kinematic model that combines the initial hand-eye transformation and distal link parameters as a whole with the sensor coordinate system as the tool frame. According to the synthesized kinematic model, an error model is constructed based on spheres' center-to-center distance errors. Consequently, the error model parameters can be identified in a calibration experiment using a three-standard-sphere target. Furthermore, the redundancy of error model parameters is eliminated to ensure the accuracy and robustness of the parameter identification. Calibration and measurement experiments are carried out based on an ER3A-C60 robot. The experimental results show that the proposed calibration method enjoys high measurement accuracy, and this efficient and flexible system is suitable for online measurement in industrial scenes. (C) 2017 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:9
相关论文
共 50 条
  • [41] A methodology for industrial robot calibration based on measurement sub-regions
    Juan S. Toquica
    José Maurício S. T. Motta
    The International Journal of Advanced Manufacturing Technology, 2022, 119 : 1199 - 1216
  • [42] Self-recalibration of a robot-assisted structured-light-based measurement system
    Xu, Jing
    Chen, Rui
    Liu, Shuntao
    Guan, Yong
    APPLIED OPTICS, 2017, 56 (32) : 8857 - 8865
  • [43] Research on online calibration system based on ABB industrial robot
    Li, Yong
    Xu, Bin
    2019 CHINESE AUTOMATION CONGRESS (CAC2019), 2019, : 1299 - 1305
  • [44] The Application of Camera Calibration Methods Based on Structured-Light Measurement
    Feng, Xiuxia
    Cao, Maoyong
    Wang, Haixia
    Collier, Michael
    2008 7TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION, VOLS 1-23, 2008, : 5090 - 5094
  • [45] The comparison of camera calibration methods based on structured-light measurement
    Feng, Xiuxia
    Cao, Maoyong
    Wang, Haixia
    Collier, Michael
    CISP 2008: FIRST INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, VOL 2, PROCEEDINGS, 2008, : 155 - 160
  • [46] Flexible Coordinate Measurement System Based on Robot for Industries
    Guo Yin
    Yang Xue-you
    Liu Chang-jie
    Ye Sheng-hua
    5TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: OPTICAL TEST AND MEASUREMENT TECHNOLOGY AND EQUIPMENT, 2010, 7656
  • [47] Flexible calibration method for an inner surface detector based on circle structured light
    Zhu, Ye
    Gu, Yonggang
    Jin, Yi
    Zhai, Chao
    APPLIED OPTICS, 2016, 55 (05) : 1034 - 1039
  • [48] Flexible calibration method for line-structured light based on binocular vision
    Zhu, Ye
    Wang, Lianpo
    Gu, Yonggang
    Zhai, Chao
    Jin, Yi
    AOPC 2017: 3D MEASUREMENT TECHNOLOGY FOR INTELLIGENT MANUFACTURING, 2017, 10458
  • [49] A Flexible Stereo Calibration for a Structured-light Profilometer
    Bevilacqua, M.
    Di Leo, G.
    Landi, M.
    Liguori, C.
    Paciello, V.
    Paolillo, A.
    Pietrosanto, A.
    2013 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2013, : 1026 - 1031
  • [50] Review of the calibration of a structured light system
    Lu, Jiawei
    Zhang, Jian
    Ye, Maosheng
    Mi, Hong
    IECON 2020: THE 46TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2020, : 4782 - 4786