Effect of operating conditions on adsorption of cephalosporin C in a column adsorber

被引:14
|
作者
Lee, JW
Jung, HJ
Moon, H
机构
[1] Department of Chemical Engineering, Seonam University
[2] Department of Chemical Technology, Chonnam National University
关键词
adsorption; cephalosporin C; column adsorber; nonionic Polymeric sorbent; operating conditions;
D O I
10.1007/BF02706824
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Adsorption of cephalosporin C on a non-ionic polymeric sorbent, SP850, was studied in a column adsorber under various operating conditions such as temperature, pH, concentration, flow rate, and LID ratio. An adsorption model was formulated by employing the surface diffusion inside resin particles. Single-species equilibrium data were simply represented by Freundlich equation. The model equations were solved numerically by an orthogonal collocation method. The model successfully simulates the adsorption behavior in a column under different operating conditions, but the considerable deviations are observed at low solution pHs, at which different ionic species may coexist.
引用
收藏
页码:277 / 284
页数:8
相关论文
共 50 条
  • [41] Adsorption mechanism of Chromium(III) from water solution on bone char: effect of operating conditions
    Valente Flores-Cano, Jose
    Leyva-Ramos, Roberto
    Carrasco-Marin, Francisco
    Aragon-Pina, Antonio
    Josafat Salazar-Rabago, Jacob
    Leyva-Ramos, Socorro
    ADSORPTION-JOURNAL OF THE INTERNATIONAL ADSORPTION SOCIETY, 2016, 22 (03): : 297 - 308
  • [42] Adsorption mechanism of Chromium(III) from water solution on bone char: effect of operating conditions
    Jose Valente Flores-Cano
    Roberto Leyva-Ramos
    Francisco Carrasco-Marin
    Antonio Aragón-Piña
    Jacob Josafat Salazar-Rabago
    Socorro Leyva-Ramos
    Adsorption, 2016, 22 : 297 - 308
  • [43] Mathematical model of supercritical CO2 adsorption on activated carbon -: Effect of operating conditions and adsorption scale-up
    Lucas, S
    Calvo, MP
    Palencia, C
    Cocero, MJ
    JOURNAL OF SUPERCRITICAL FLUIDS, 2004, 32 (1-3): : 193 - 201
  • [44] The effect of operating variables on the performance of a packed column still
    Duncan, DW
    Koffolt, JH
    Withrow, JR
    TRANSACTIONS OF THE AMERICAN INSTITUTE OF CHEMICAL ENGINEERS, 1942, 38 (02): : 0259 - 0281
  • [45] OPTIMIZATION OF OPERATING CONDITIONS IN A PACKED LIQUID-LIQUID EXTRACTION COLUMN
    MOORHEAD, DH
    HIMMELBLAU, DM
    INDUSTRIAL & ENGINEERING CHEMISTRY FUNDAMENTALS, 1962, 1 (01): : 68 - &
  • [46] Dynamic model of a countercurrent packed column operating at high pressure conditions
    Ruivo, R
    Paiva, A
    Mota, JPB
    Simoes, P
    JOURNAL OF SUPERCRITICAL FLUIDS, 2004, 32 (1-3): : 183 - 192
  • [47] INFLUENCE OF OPERATING CONDITIONS ON LOADS AND FATIGUE STRENGTH IN A ROD COLUMN OF PCP
    Urazakov, Kamil R.
    Latypov, Bulat M.
    BULLETIN OF THE TOMSK POLYTECHNIC UNIVERSITY-GEO ASSETS ENGINEERING, 2020, 331 (05): : 120 - 127
  • [48] RECTIFICATION COLUMN CONTACT EQUIPMENT OPERATING UNDER CYCLIC CONDITIONS.
    Gel'perin, N.I.
    Lenskii, M.S.
    Migai, A.A.
    Golant, O.Yu.
    Chemical and Petroleum Engineering, 1985, 21 (3-4) : 133 - 134
  • [49] NONSTATIONARY MASS TRANSFER IN A DRYING CHAMBER-ADSORBER SYSTEM UNDER CONDITIONS OF NONEQUILIBRIUM ADSORPTION OF STEAM
    Vakul'chik, P. A.
    Kulikovskii, V. K.
    Pavlyukevich, N. V.
    Aristov, Yu. I.
    JOURNAL OF ENGINEERING PHYSICS AND THERMOPHYSICS, 2012, 85 (06) : 1327 - 1330
  • [50] Prediction of the operating conditions in a batch distillation column using a shortcut method
    Ehsani, MR
    IRANIAN JOURNAL OF CHEMISTRY & CHEMICAL ENGINEERING-INTERNATIONAL ENGLISH EDITION, 2002, 21 (02): : 118 - 125