Effect of operating conditions on adsorption of cephalosporin C in a column adsorber

被引:14
|
作者
Lee, JW
Jung, HJ
Moon, H
机构
[1] Department of Chemical Engineering, Seonam University
[2] Department of Chemical Technology, Chonnam National University
关键词
adsorption; cephalosporin C; column adsorber; nonionic Polymeric sorbent; operating conditions;
D O I
10.1007/BF02706824
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Adsorption of cephalosporin C on a non-ionic polymeric sorbent, SP850, was studied in a column adsorber under various operating conditions such as temperature, pH, concentration, flow rate, and LID ratio. An adsorption model was formulated by employing the surface diffusion inside resin particles. Single-species equilibrium data were simply represented by Freundlich equation. The model equations were solved numerically by an orthogonal collocation method. The model successfully simulates the adsorption behavior in a column under different operating conditions, but the considerable deviations are observed at low solution pHs, at which different ionic species may coexist.
引用
收藏
页码:277 / 284
页数:8
相关论文
共 50 条