A learning curve analysis of ultrasound-guided in-plane and out-of-plane vascular access training with Perk Tutor

被引:1
|
作者
Xia, Sean [1 ,2 ]
Keri, Zsuzsanna [1 ]
Holden, Matthew S. [1 ]
Hisey, Rebecca [1 ]
Lia, Hillary [1 ]
Ungi, Tamas [1 ]
Mitchell, Christopher H. [3 ]
Fichtinger, Gabor [1 ]
机构
[1] Queens Univ, Sch Comp, Lab Percutaneous Surg, Kingston, ON, Canada
[2] Queens Univ, Sch Med, Kingston, ON, Canada
[3] Sir Charles Gairdner Hosp, Dept Anaesthesia, Perth, WA, Australia
基金
加拿大自然科学与工程研究理事会; 加拿大健康研究院;
关键词
Perk Tutor; 3D Slicer; PLUS Toolkit; Image-Guided Intervention; Ultrasound-guided needle insertion; Learning curve analysis; Procedural skills education; Competency-based medical education; LUMBAR PUNCTURE; SYSTEM;
D O I
10.1117/12.2293789
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
PURPOSE: Under ultrasound guidance, procedures that have been traditionally performed using landmark approaches have become safer and more efficient. However, inexperienced trainees struggle with coordinating probe handling and needle insertion. We aimed to establish learning curves to identify the rate of acquisition of in-plane and out-of-plane vascular access skill in novice medical trainees. METHODS: Thirty-eight novice participants were randomly assigned to perform either in-plane or out-of-plane insertions. Participants underwent baseline testing, four practice insertions (with 3D visualization assistance), and final testing; performance metrics were computed for all procedures. Five expert participants performed insertions in both approaches to establish expert performance metric benchmarks. RESULTS: In-plane novices (n=19) demonstrated significant final reductions in needle path inefficiency (45.8 vs. 127.1, p<0.05), needle path length (41.1 mm vs. 58.0 mm. p<0.05). probe path length (11.6 mm vs. 43.8 mm. p<0.01). and maximal distance between needle and ultrasound plane (3.1 mm vs. 5.5 mm, p<0.05) and surpassed expert benchmarks in average and maximal rotational error. Out-of-plane novices (n=19) demonstrated significant final reductions in all performance metrics, including needle path inefficiency (54.4 vs. 1102, p<0.0 1). maximum distance of needle past plane (0.0 mm vs. 7.3 mm, p<0.01). and total time of needle past plane (0.0 s vs. 3.4 s, p<0.01) and surpassed expert benchmarks in maximum distance and time of needle past plane. CONCLUSION: Our learning curves quantify improvement in in-plane and out-of-plane vascular access skill with 3D visualization over multiple attempts. The training session enables more than half of novices to approach expert performance benchmarks.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Ultrasound-guided short-axis out-of-plane versus long-axis in-plane technique of Posterior Tibial Artery Cannulation in adult patients: The POTACUT (POsterior Tibial Artery Access with Ultrasound Trial) Randomized Trial
    Sultana, Shereen
    Sharma, Ankur
    Mukesh, Arun
    Goyal, Shilpa
    Rathod, Darshna
    Kumari, Kamlesh
    Meshram, Tanvi
    Bhatia, Pradeep
    Kothari, Nikhil
    Goel, Akhil Dhanesh
    JOURNAL OF VASCULAR ACCESS, 2024,
  • [42] A trigonometric method to confirm needle tip position during out-of-plane ultrasound-guided regional blockade
    Ban C. H. Tsui
    Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 2012, 59 : 501 - 502
  • [43] A trigonometric method to confirm needle tip position during out-of-plane ultrasound-guided regional blockade
    Tsui, Ban C. H.
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2012, 59 (05): : 501 - 502
  • [44] Ultrasound-guided short-axis out-of-plane vs. long-axis in-plane technique for radial artery catheterization: an updated meta-analysis of randomized controlled trials
    Wang, H-H
    Wang, J-J
    Chen, W-T
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2022, 26 (06) : 1914 - 1922
  • [45] Combining in-plane and out-of-plane behaviour of masonry infills in the seismic analysis of RC buildings
    Manfredi, V.
    Masi, A.
    EARTHQUAKES AND STRUCTURES, 2014, 6 (05) : 515 - 537
  • [46] Dynamic ultrasound-guided, short axis, out-of-plane radial artery cannulation: the 'follow the tip' technique
    Goh, S. L.
    Tan, C. O.
    Weinberg, L.
    ANAESTHESIA AND INTENSIVE CARE, 2013, 41 (03) : 431 - 432
  • [47] In-plane and out-of-plane free vibration analysis of Archimedes-type spiral springs
    Yildirim, V
    JOURNAL OF APPLIED MECHANICS-TRANSACTIONS OF THE ASME, 1997, 64 (03): : 557 - 561
  • [48] Long-Axis In-Plane Approach Versus Short-Axis Out-of-Plane Approach for Ultrasound-Guided Central Venous Catheterization in Pediatric Patients: A Randomized Controlled Trial*
    Takeshita, Jun
    Tachibana, Kazuya
    Nakajima, Yasufumi
    Nagai, Gaku
    Fujiwara, Ai
    Hamaba, Hirofumi
    Matsuura, Hideki
    Yamashita, Tomonori
    Shime, Nobuaki
    PEDIATRIC CRITICAL CARE MEDICINE, 2020, 21 (11) : E996 - E1001
  • [49] Combined short-axis out-of-plane and long-axis in-plane approach versus long-axis in-plane approach for ultrasound-guided central venous catheterization in infants and small children: A randomized controlled trial
    Takeshita, Jun
    Nakajima, Yasufumi
    Tachibana, Kazuya
    Hamaba, Hirofumi
    Yamashita, Tomonori
    Shime, Nobuaki
    PLOS ONE, 2022, 17 (09):
  • [50] Training novice in ultrasound-guided venipuncture: A randomized controlled trial comparing out-of-plane needle-guided versus free-hand ultrasound techniques on a simulator
    Raft, Julien
    Dupanloup, Daniele
    Clerc-Urmes, Isabelle
    Baumann, Cedric
    Richebe, Philippe
    Bouaziz, Herve