Evaluation of the effect of noise in a digital holographic system on the quality of reconstructed particle image

被引:1
|
作者
Davydova, Alexandra [1 ,2 ]
Dyomin, Victor [1 ]
Polovtsev, Igor [1 ]
机构
[1] Natl Res Tomsk State Univ, 36 Lenin Ave, Tomsk 634050, Russia
[2] VE Zuev Inst Atmospher Opt SB RAS, 1 Academician Zuev Sq, Tomsk 634055, Russia
关键词
digital holography; noise; twin-image; speckle; IN-LINE; REDUCTION; PLANKTON; SIZE;
D O I
10.1117/12.2575603
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
The paper considers the distortions of a real holographic image of particles exerting the greatest impact on the image quality: distortions associated with the influence of a virtual particle image and speckle structure of image caused by coherent noises of the medium. The described numerical experiments showed that it is possible to arrange such conditions for hologram recording, its processing and image reconstruction, under which a particle image with the impact of a twin image is suitable for recognizing and determining the characteristics of a particle.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Investigation of The Focusing Effect on The Reconstructed Image Quality in Digital Holographic Microscopy
    Kaya, Gulhan Ustabas
    Onur, Tugba Ozge
    2020 ZOOMING INNOVATION IN CONSUMER TECHNOLOGIES CONFERENCE (ZINC), 2020, : 1 - 4
  • [2] Effect of reconstructed light on quality of reconstructed image of digital color hologram
    Ge, Bao-Zhen
    Mu, Bing
    Zhao, Hui-Ying
    Lu, Qie-Ni
    Zhang, Yi-Mo
    Guangdianzi Jiguang/Journal of Optoelectronics Laser, 2003, 14 (12): : 1344 - 1348
  • [3] Simulation of the Effect of Noise on Terahertz Digital Holography Reconstructed Image
    Lin, Ping
    Li, Qi
    Shen, Zuochun
    14TH NATIONAL CONFERENCE ON LASER TECHNOLOGY AND OPTOELECTRONICS (LTO 2019), 2019, 11170
  • [4] Digital holographic display based on Digital Micromirror Device and quality enhancement of its reconstructed image
    Department of Physics, Sichuan University, Chengdu 610064, China
    Guangzi Xuebao, 2008, 5 (952-956):
  • [5] Shot-noise influence on the reconstructed phase image signal-to-noise ratio in digital holographic microscopy
    Charriere, Florian
    Colomb, Tristan
    Montfort, Frederic
    Cuche, Etienne
    Marquet, Pierre
    Depeursinge, Christian
    APPLIED OPTICS, 2006, 45 (29) : 7667 - 7673
  • [6] Focal depth research of digital holographic reconstructed image
    Li Jun-Chang
    ACTA PHYSICA SINICA, 2012, 61 (13)
  • [7] Evaluating the effect of dose on reconstructed image quality in digital tomosynthesis
    Kempston, Michael P.
    Mainprize, James G.
    Yaffe, Martin J.
    DIGITAL MAMOGRAPHY, PROCEEDINGS, 2006, 4046 : 490 - 497
  • [8] Speckle denoising for digital holographic reconstructed image base on image edge detection
    Jia Q.
    Li Z.
    Liu X.
    Advances in Intelligent and Soft Computing, 2011, 105 : 303 - 308
  • [9] Speckle Denoising for Digital Holographic Reconstructed Image Base on Image Edge Detection
    Jia, Qin
    Li, ZhiQuan
    Liu, XueFei
    ADVANCES IN COMPUTER SCIENCE, INTELLIGENT SYSTEM AND ENVIRONMENT, VOL 2, 2011, 105 : 303 - +
  • [10] Usage of segmentation for noise elimination in reconstructed images in digital holographic interferometry
    Kaya, Gulhan Ustabas
    Sarac, Zehra
    TURKISH JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCES, 2018, 26 (01) : 234 - 244