Role of IMRT in reducing penile doses in dose escalation for prostate cancer

被引:36
|
作者
Sethi, A
Mohideen, N
Leybovich, L
Mulhall, J
机构
[1] Loyola Univ, Ctr Med, Dept Radiat Oncol, Maywood, IL 60153 USA
[2] Loyola Univ, Ctr Med, Dept Urol, Maywood, IL 60153 USA
关键词
3D-CRT; IMRT; corporal bodies; dose escalation;
D O I
10.1016/S0360-3016(02)04164-0
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: In three-dimensional conformal radiotherapy (3D-CRT), penile tissues adjacent to the prostate are exposed to significant doses of radiation. This is likely to be a factor in development of posttreatment erectile dysfunction. In this study, we investigate whether intensity-modulated radiation therapy (IMRT) leads to lower radiation exposure to proximal penile tissues (PPT) when compared with 3D-CRT. Methods and Materials: Ten randomly selected patients with clinically localized prostate cancer constituted the study group. Using identical structure sets, 3D-CRT and IMRT plans were designed for each patient. For IMRT, both tomographic (TOMO) and step-and-shoot (SS) techniques were used. Treatment plans were developed using 18 MV photons for 3D-CRT, 6 MV photons for TOMO, and 6 MV and 18 MV photons for SS plans. The PPT up to the beginning of the penile shaft (usually measuring 2-3 cm) was outlined by a team composed of a board-certified urologist and a radiation oncologist. The outlined PPT was subdivided into three segments (P1, P2, P3), and the radiation dose to each segment and to the entire structure was calculated. In addition, PPT was subdivided into corporal cavernosa (CC) and corpus spongiosum (bulb). The prostate dose was escalated from 73.8 Gy to 81 Gy to 90 Gy. Target D-95 (dose to 95% volume), critical structure D-5 (dose to 5% volume), and D-mean (mean dose) were used in the comparison among treatment plans. Because 3D-CRT uses larger field margins than does IMRT, target and critical structure doses were recalculated in 3D-CRT plans employing field margins obtained from IMRT plans. Planning target volumes in original and modified 3D-CRT plans were the same. Results: Compared with 3D-CRT plans, the mean PPT doses were reduced by 40.2%, 43.6%, and 46.2%, respectively, at the three prescription dose levels in TOMO plans. The average D-mean for CC was lower by 46.4%, 48.4%, and 51.4%, whereas the average bulb D-mean was reduced by 44.2%, 44.9%, and 47.9%, respectively. There was also considerable sparing of P1, with a reduction in average D-mean of 41.9%, 45.5%, and 48.5% compared with 3D-CRT. All differences between 3D-CRT and IMRT doses were statistically significant (p < 0.001). Similar improvements were noticed in maximum doses (D5) for penile structures. The percent dose reduction with IMRT plans improved as prostate dose was escalated. When compared with 3D-CRT plans with reduced fields, IMRT plans showed slightly smaller but still significant improvements in critical structure doses (p < 0.001). Compared with SS plans, TOMO plans produced improved sparing of dose to critical structures. Conclusions: IMRT allows for dose escalation in prostate cancer while keeping penile tissue doses significantly lower compared to conformal radiotherapy. This may result in improved potency rates over current results observed with 3D-CRT. (C) 2003 Elsevier Science Inc.
引用
收藏
页码:970 / 978
页数:9
相关论文
共 50 条
  • [21] What is the role of radiation dose escalation in the treatment of localized prostate cancer?
    Michel Bolla
    Nature Clinical Practice Urology, 2008, 5 : 418 - 419
  • [22] What is the role of radiation dose escalation in the treatment of localized prostate cancer?
    Bolla, Michel
    NATURE CLINICAL PRACTICE UROLOGY, 2008, 5 (08): : 418 - 419
  • [23] HDR brachytherapy and online image-guided adaptive IMRT for dose escalation in prostate cancer: Comparison of brachytherapy and IMRT boosts
    Fatyga, M.
    Williamson, J.
    Dogan, N.
    Todor, D.
    Siebers, J.
    George, R.
    Hagan, M.
    Barani, I.
    MEDICAL PHYSICS, 2007, 34 (06) : 2632 - 2632
  • [24] IMRT and dose escalation in prostate cancer - Inclusion of individual intrafractional prostate motion in the determination of CTV-PTV margins
    Oppitz, U.
    Lengkeek, V
    Wulf, J.
    Muench, K.
    Neuenschwander, H.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2007, 183 : 174 - 174
  • [25] Dose escalation of IMRT prostate cancer - Adverse spectrum and treatment results from the Sudharz Hospital, Nordhausen
    Mikulik, O.
    Weber, A.
    Hentschel, B.
    Strauss, D.
    Arnhold, I.
    Malich, A.
    Oehler, W.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2009, 185 : 111 - 111
  • [26] Focal IMRT dose escalation for prostate cancer using PSMA PET/CT and MRI: a planning study
    Zamboglou, C.
    Thomann, B.
    Koubar, K.
    Sachpazidis, I.
    Bronsert, P.
    Krauss, T.
    Rischke, H. C.
    Salman, N.
    Reichel, K.
    Meyer, P. T.
    Bock, M.
    Baltas, D.
    Grosu, A. L.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S426 - S427
  • [27] DOSE ESCALATION IN THE RADIATION THERAPY OF PROSTATE CANCER
    Schulz, Robert J.
    Kagan, A. Robert
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (05): : 1289 - 1291
  • [28] Hazards of dose escalation in prostate cancer radiotherapy
    Kuban, D
    Pollack, A
    Huang, E
    Levy, L
    Dong, L
    Starkschall, G
    Rosen, I
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 57 (05): : 1260 - 1268
  • [29] Role of Multiparametric MRI in Defining Lesions for Targeted Dose Escalation in Prostate Cancer
    Lorentz, W.
    Demanes, D. J.
    Steinberg, M. L.
    Park, S.
    Kamrava, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S417 - S418
  • [30] IGRT DOSE ESCALATION STRATEGIES FOR PROSTATE CANCER
    Kuechler, S.
    Volegova-Neher, N.
    Roehner, F.
    Bruggmoser, G.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S444 - S445