Persistently Raised Serum Titanium Levels After Spinal Instrumentation in Children

被引:8
|
作者
Cundy, Peter J. [1 ,2 ]
Antoniou, Georgia [1 ]
Freeman, Brian J. C. [1 ,2 ]
Cundy, William J. [1 ]
机构
[1] Womens & Childrens Hosp, Dept Orthopaed Surg, 72 King William St, Adelaide, SA 5006, Australia
[2] Univ Adelaide, Ctr Orthopaed & Trauma Res, Adelaide, SA, Australia
关键词
titanium; spine; children; surgery; chromium; cobalt; nickel; serum; birth defects; scoliosis; METAL-ION RELEASE;
D O I
10.1097/BRS.0000000000004406
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Prospective study of patients undergoing elective spinal deformity surgery with repeated testing for circulating metal ions including preoperative levels acting as controls. Objective. The aim was to determine if levels of particular circulating metal ions are maintained to two years postsurgery including different implant systems and rods. Summary of Background Data. Adults having hip replacements, especially metal-on-metal bearings, may develop high metal ion levels. Pediatric spinal implants are known to cause circulating metal ions, notably titanium, chromium, cobalt, and nickel. Materials and Methods. Fifty-six children having spinal deformity surgery were studied with repeated testing for circulating metal ions, using high-resolution inductively coupled plasma mass spectrometry. Linear mixed-effects models adjusting for repeated measurements over time were used to analyze levels of titanium, cobalt, chromium, and nickel. Results. Titanium levels showed a rapid increase by seven days and a peak at 30 days that was essentially maintained at the two-year assay. At two years, titanium levels were 5.14 times greater compared with the presurgery control level (P<0.0001). Cobalt levels were shown to gradually rise to a peak at 30 days and then slowly decline but remained 1.74 times above mean baseline level at two years (P=0.0004), with a declining trajectory. Chromium and nickel levels rose immediately postoperatively and then steadily declined to baseline by six months and remained at baseline at two years. The five implant systems tested had generally equivalent results. Conclusion. The persistent and rising levels of titanium, in a predominantly female population, is concerning. Titanium is known to cross the placental barrier and enter the circulation of the fetus in rodents and humans, and to accumulate in solid organs especially the liver, spleen, heart, and lymph nodes in humans. This potentially exposes the offspring of mothers with spinal implants to titanium, with potential teratogenic effects.
引用
收藏
页码:1241 / 1247
页数:7
相关论文
共 50 条
  • [41] SPONDYLOLYSIS AFTER SPINAL INSTRUMENTATION IN OSTEOGENESIS IMPERFECTA
    BARRACK, RL
    WHITECLOUD, TS
    SKINNER, HB
    SOUTHERN MEDICAL JOURNAL, 1984, 77 (11) : 1453 - 1454
  • [42] RAISED SERUM PROLACTIN LEVELS ASSOCIATED WITH HIRSUTISM AND AMENORRHEA
    SEPPALA, M
    HIRVONEN, E
    BRITISH MEDICAL JOURNAL, 1975, 4 (5989): : 144 - 145
  • [43] RATIONAL TESTING Interpreting raised serum ferritin levels
    Koperdanova, Marianna
    Cullis, Jonathan O.
    BMJ-BRITISH MEDICAL JOURNAL, 2015, 351
  • [44] Management of postoperative infections after spinal instrumentation
    Levi, ADO
    Dickman, CA
    Sonntag, VKH
    JOURNAL OF NEUROSURGERY, 1997, 86 (06) : 975 - 980
  • [45] RAISED SERUM AFP LEVELS AND FETAL RENAL AGENESIS
    BALFOUR, RP
    LAURENCE, KM
    LANCET, 1980, 1 (8163): : 317 - 317
  • [46] RAISED SERUM IGM LEVELS IN NEONATAL ENDEMIC DIARRHOEA
    HAIDER, SA
    ARCHIVES OF DISEASE IN CHILDHOOD, 1971, 46 (248) : 566 - &
  • [47] FAILURE OF PYRIDOXINE TO SUPPRESS RAISED SERUM PROLACTIN LEVELS
    DEWAAL, JM
    STEYN, AF
    HARMS, JHK
    SLABBER, CF
    PANNALL, PR
    SOUTH AFRICAN MEDICAL JOURNAL, 1978, 53 (08): : 293 - 294
  • [48] Raised serum interleukin 15 levels in Kawasaki disease
    Jang, GC
    Kim, HY
    Ahn, SY
    Kim, DS
    ANNALS OF THE RHEUMATIC DISEASES, 2003, 62 (03) : 264 - 266
  • [49] APPARENTLY RAISED SERUM CREATININE LEVELS DUE TO CEPHALOSPORINS
    PIVERAL, K
    MILLER, SC
    BAIRD, DR
    PLEASANTS, RA
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1986, 255 (03): : 323 - 324
  • [50] Raised TSH serum levels in AGA and SGA children born prematurely: a follow-up study
    Leitner, Yvonne A.
    Pellegrini, Francesca
    Cassar, Walburga
    Calebiro, Davide
    Wanker, Petra
    Persani, Luca
    Radetti, Giorgio
    HORMONE RESEARCH, 2009, 72 : 305 - 305