Modern trends in base isolation applications for seismic protection of historic buildings

被引:0
|
作者
Iskhakov, I. [1 ]
Ribakov, Y. [1 ]
机构
[1] Coll Judea & Samaria, Ariel, Israel
关键词
historic buildings; base isolation; impulse tests; variable friction dampers; seismic response;
D O I
10.2495/STR070581
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Historical buildings have relatively low height, are usually massive and their natural vibration period is rather low. Hence if such buildings are located in a seismically active region, using base isolation systems is a very effective way for improving their dynamic response. The idea of base isolation was known hundreds years ago, however practical implementation of modem base isolators started in the last few decades. The main advantage of a base isolation system is that no elements should be added to an isolated building, which is especially important for heritage architecture. A traditional base isolation system is obtained by using two main base isolator types - elastomeric (neoprene) bearings or friction pendulums. Hundreds of buildings all over the world are provided with such isolators and have proved enhanced dynamic behaviour. Design of base isolation systems and selection of their properties usually depend on dynamic characteristics of the isolated building. The latter can be obtained by non-destructive impulse testing of the structure before its protection. An appropriate method for structural dynamic parameters experimental estimation was developed by the authors. For this reason an impulse test was carried out on a three-story structural part of a building designed for a seismic region. In some cases the displacements at the base isolation level are rather big and exceed the allowed limits. In such cases it is recommended to add dampers to the base isolation system. Effective variable friction dampers were proposed and tested by the authors. These dampers significantly reduce the displacements at the isolator level (between the first floor column and foundation) and also yield further improvement in the seismic response of a building.
引用
收藏
页码:623 / +
页数:2
相关论文
共 50 条
  • [31] Hybrid strategy for the seismic retrofitting of existing buildings through Base Isolation System
    Giuseppe, Brandonisio
    Guidi, Laura Giovanna
    Camarda, Guido
    Sorrentino, Paola
    De Luca, Antonello
    [J]. XIX ANIDIS CONFERENCE, SEISMIC ENGINEERING IN ITALY, 2023, 44 : 1292 - 1299
  • [32] Control of torsional modes in buildings under seismic excitation by adaptive base isolation
    Sener, M
    Utku, S
    [J]. PASSIVE DAMPING AND ISOLATION - SMART STRUCTURES AND MATERIALS 1996, 1996, 2720 : 145 - 156
  • [33] Enhancing the Seismic Response of Residential RC Buildings with an Innovative Base Isolation Technique
    Belbachir, Asma
    Benanane, Abdelkader
    Ouazir, Abderrahmane
    Harrat, Zouaoui R.
    Hadzima-Nyarko, Marijana
    Radu, Dorin
    Isik, Ercan
    Louhibi, Zouhir S. M.
    Amziane, Sofiane
    [J]. SUSTAINABILITY, 2023, 15 (15)
  • [34] Efficiency of base isolation systems in structural seismic protection and energetic assessment
    Marano, GC
    Greco, R
    [J]. EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2003, 32 (10): : 1505 - 1531
  • [35] Seismic Retrofitting Techniques for Historic Adobe Buildings
    Michiels, Tim L. G.
    [J]. INTERNATIONAL JOURNAL OF ARCHITECTURAL HERITAGE, 2015, 9 (08) : 1059 - 1068
  • [36] Seismic isolation of hospital buildings
    Soldatova, Liudmila
    Jumukov, Sulaiman
    [J]. SMART STRUCTURES AND SYSTEMS, 2006, 2 (04) : 329 - 337
  • [37] STUDIES ON SEISMIC ISOLATION OF BUILDINGS
    FERRITTO, JM
    [J]. JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1991, 117 (11): : 3293 - 3314
  • [38] SEISMIC RETROFIT OF HISTORICAL BUILDINGS WITH SEISMIC ISOLATION
    Clemente, P.
    De Stefano, A.
    Zago, R.
    [J]. STRUCTURAL ANALYSIS OF HISTORICAL CONSTRUCTIONS, VOLS 1-3, 2012, : 1441 - 1448
  • [40] Fire cause and protection of Taiwanese historic buildings
    Chuang, Ying-Ji
    Chiou, Chien-Wei
    Chiu, Jin-Yin
    Chueng, Ying-Ji
    Lin, Ching-Yuan
    [J]. Journal of Applied Fire Science, 2009, 19 (03): : 217 - 230