Modern trends in base isolation applications for seismic protection of historic buildings

被引:0
|
作者
Iskhakov, I. [1 ]
Ribakov, Y. [1 ]
机构
[1] Coll Judea & Samaria, Ariel, Israel
关键词
historic buildings; base isolation; impulse tests; variable friction dampers; seismic response;
D O I
10.2495/STR070581
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Historical buildings have relatively low height, are usually massive and their natural vibration period is rather low. Hence if such buildings are located in a seismically active region, using base isolation systems is a very effective way for improving their dynamic response. The idea of base isolation was known hundreds years ago, however practical implementation of modem base isolators started in the last few decades. The main advantage of a base isolation system is that no elements should be added to an isolated building, which is especially important for heritage architecture. A traditional base isolation system is obtained by using two main base isolator types - elastomeric (neoprene) bearings or friction pendulums. Hundreds of buildings all over the world are provided with such isolators and have proved enhanced dynamic behaviour. Design of base isolation systems and selection of their properties usually depend on dynamic characteristics of the isolated building. The latter can be obtained by non-destructive impulse testing of the structure before its protection. An appropriate method for structural dynamic parameters experimental estimation was developed by the authors. For this reason an impulse test was carried out on a three-story structural part of a building designed for a seismic region. In some cases the displacements at the base isolation level are rather big and exceed the allowed limits. In such cases it is recommended to add dampers to the base isolation system. Effective variable friction dampers were proposed and tested by the authors. These dampers significantly reduce the displacements at the isolator level (between the first floor column and foundation) and also yield further improvement in the seismic response of a building.
引用
收藏
页码:623 / +
页数:2
相关论文
共 50 条
  • [1] Base isolation for retrofitting historic buildings: Evaluation of seismic performance through experimental investigation
    De Luca, A
    Mele, E
    Molina, J
    Verzeletti, G
    Pinto, AV
    [J]. EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2001, 30 (08): : 1125 - 1145
  • [2] Analytical and numerical study of a smart sliding base isolation system for seismic protection of buildings
    Madden, GJ
    Wongprasert, N
    Symans, MD
    [J]. COMPUTER-AIDED CIVIL AND INFRASTRUCTURE ENGINEERING, 2003, 18 (01) : 19 - 30
  • [3] Low-Cost Base-Isolation System for Seismic Protection of Rural Buildings
    Nanda, Radhikesh P.
    Shrikhande, Manish
    Agarwal, Pankaj
    [J]. PRACTICE PERIODICAL ON STRUCTURAL DESIGN AND CONSTRUCTION, 2016, 21 (01)
  • [4] Analytical and numerical study of a smart sliding base isolation system for seismic protection of buildings
    Madden, GJ
    Wongprasert, N
    Symans, MD
    [J]. SMART STRUCTURES AND MATERIALS 2000: SMART SYSTEMS FOR BRIDGES, STRUCTURES, AND HIGHWAYS, 2000, 3988 : 18 - 29
  • [5] SEISMIC BASE ISOLATION OF ASYMMETRIC SHEAR BUILDINGS
    EISENBERGER, M
    RUTENBERG, A
    [J]. ENGINEERING STRUCTURES, 1986, 8 (01) : 2 - 8
  • [6] BASE ISOLATION FOR SEISMIC RETROFITTING OF DAMAGED BUILDINGS
    Mezzi, Marco
    Petrella, Paolo
    [J]. IMPLEMENTING INNOVATIVE IDEAS IN STRUCTURAL ENGINEERING AND PROJECT MANAGEMENT, 2015, : 431 - 436
  • [7] Multiaxial active isolation for seismic protection of buildings
    Chang, Chia-Ming
    Spencer, Billie F., Jr.
    Shi, Pengfei
    [J]. STRUCTURAL CONTROL & HEALTH MONITORING, 2014, 21 (04): : 484 - 502
  • [8] The Sliding Isolation Pendulum for the seismic protection of buildings
    Huber, P.
    Medeot, R.
    [J]. STRUCTURES UNDER SHOCK AND IMPACT X, 2008, 98 : 323 - 332
  • [9] Seismic Base Isolation of a Strategic Historic Masonry Building
    Zordan, Tobia
    Romano, Alessandra
    Parisi, Fulvio
    [J]. SEISMIC ISOLATION, ENERGY DISSIPATION AND ACTIVE VIBRATION CONTROL OF STRUCTURES, 17WCSI 2022, 2023, 309 : 524 - 531
  • [10] Seismic retrofit of church buildings through base isolation
    De Luca, A
    Mele, E
    Giagnuolo, C
    [J]. STRUCTURAL CONTROL FOR CIVIL AND INFRASTRUCTURE ENGINEERING, 2001, : 119 - 126