Bubble CPAP for Respiratory Distress Syndrome in Preterm Infants

被引:47
|
作者
Koti, Jagdish [2 ]
Murki, Srinivas [1 ]
Gaddam, Pramod [1 ]
Reddy, Anupama [1 ]
Reddy, M. Dasaradha Rami [1 ]
机构
[1] Fernandez Hosp, Hyderabad 503001, Andhra Pradesh, India
[2] Yashodha Hosp, Hyderabad, Andhra Pradesh, India
关键词
Bubble CPAP; CPAP failure; Management; Prematurity; Respiratory distress syndrome; PRESSURE; FAILURE;
D O I
10.1007/s13312-010-0021-6
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Objectives: To ascertain the immediate outcome of preterm infants with respiratory distress syndrome (RDS) on Bubble CPAP and identify risk factors associated with its failure. Study design: Prospective analytical study. Subjects: Inborn preterm infants (gestation 28 to 34 weeks) admitted to the NICU with respiratory distress and chest X-ray suggestive of RDS. Intervention: Bubble CPAP with bi-nasal prongs. Primary outcome: CPAP failures-infants requiring ventilation in the first one week. Results: 56 neonates were enrolled in the study. 14 (25%) babies failed CPAR The predictors of failure were; no or only partial exposure to antenatal steroids, white-out on the chest X-ray, patent ductus arteriosus, sepsis/pneumonia and Downe's score >7 or FiO(2) >= 50% after 15-20 minutes of CPAP. Other maternal and neonatal variables did not influence the need for ventilation. Rates of mortaility and duration of oxygen requirement was significantly higher in babies who failed CPAP. Only two infants developed pneumothorax. No baby had chronic lung disease. Conclusion: Infants with no or partial exposure to antenatal steroids, white-out chest X-ray, patent ductus arteriosus, sepsis/pneumonia and those with higher FiO(2) requirement after initial stabilization on CPAP are at high risk of CPAP failure (needing mechanical ventilation). Bubble CPAP is safe for preterm infants with RDS.
引用
收藏
页码:139 / 143
页数:5
相关论文
共 50 条
  • [11] Diuretics for respiratory distress syndrome in preterm infants
    Brion, L. P.
    Soll, R. F.
    [J]. COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2008, (01):
  • [12] CPAP with variable flow is comparable with Bubble CPAP in preterm infants
    CM Rebello
    ACZ Yagui
    LA Vale
    LB Haddad
    C Prado
    FS Rossi
    AD Deutsch
    [J]. Critical Care, 15 (Suppl 2):
  • [13] Aerosolized Surfactant for Preterm Infants with Respiratory Distress Syndrome
    Brasher, Mandy
    Raffay, Thomas M.
    Cunningham, M. Douglas
    Abu Jawdeh, Elie G.
    [J]. CHILDREN-BASEL, 2021, 8 (06):
  • [14] MIST or INSURE in Preterm Infants with Respiratory Distress Syndrome
    Sayed, Marwa Kamel Mohammed
    Hassanien, Farouk Elsayed
    Khalaf, Mostafa Shafeek
    Badawy, Ahlam Badawy Ali
    [J]. JOURNAL OF CHILD SCIENCE, 2024, 14 (01): : e66 - e74
  • [15] Parental representations of preterm infants with a respiratory distress syndrome
    Ansermet, F
    Muller-Nix, C
    Pierrehumbert, B
    Forcada, M
    Fawer, CL
    Calame, A
    [J]. PEDIATRIC PULMONOLOGY, 1997, : 256 - 256
  • [16] Alternative therapies for respiratory distress syndrome in preterm infants
    Sinha, Ian P.
    Sinha, Sunil K.
    [J]. RESEARCH AND REPORTS IN NEONATOLOGY, 2011, 1 : 67 - 74
  • [17] Nasal Jet-CPAP (variable flow) versus Bubble-CPAP in preterm infants with respiratory distress: an open label, randomized controlled trial
    A Bhatti
    J Khan
    S Murki
    V Sundaram
    S S Saini
    P Kumar
    [J]. Journal of Perinatology, 2015, 35 : 935 - 940
  • [18] Nasal Jet-CPAP (variable flow) versus Bubble-CPAP in preterm infants with respiratory distress: an open label, randomized controlled trial
    Bhatti, A.
    Khan, J.
    Murki, S.
    Sundaram, V.
    Saini, S. S.
    Kumar, P.
    [J]. JOURNAL OF PERINATOLOGY, 2015, 35 (11) : 935 - 940
  • [19] Fraction of Inspired Oxygen as a Predictor of CPAP Failure in Preterm Infants with Respiratory Distress Syndrome: A Prospective Multicenter Study
    Gulczynska, Ewa
    Szczapa, Tomasz
    Hozejowski, Roman
    Borszewska-Kornacka, Maria Katarzyna
    Rutkowska, Magdalena
    [J]. NEONATOLOGY, 2019, 116 (02) : 171 - 178
  • [20] Bi-level CPAP does not change central blood flow in preterm infants with respiratory distress syndrome
    Aquilano, Giulia
    Galletti, Silvia
    Aceti, Arianna
    Vitali, Francesca
    Faldella, Giacomo