NON-ENHANCED PATTERN ON CONTRAST-ENHANCED ULTRASOUND IN THE LOCAL EFFICACY ASSESSMENT OF IRREVERSIBLE ELECTROPORATION ABLATION OF PANCREATIC ADENOCARCINOMA

被引:2
|
作者
Lin, Manxia [1 ]
Xie, Xiaoyan [1 ]
Xu, Ming [1 ]
Feng, Shiting [2 ]
Tian, Wenshuo [1 ]
Zhuang, Bowen [1 ]
Su, Liya [1 ]
Ye, Jieyi [1 ]
Lin, Jinhua [1 ]
Liang, Ping [3 ]
Yu, Jie [3 ]
Kuang, Ming [1 ,4 ]
机构
[1] Sun Yat Sen Univ, Div Intervent Ultrasound, Dept Med Ultrason, Affiliated Hosp 1,Inst Study Diagnost & Intervent, Guangzhou, Guangdong, Peoples R China
[2] Sun Yat Sen Univ, Dept Radiol, Affiliated Hosp 1, Guangzhou, Guangdong, Peoples R China
[3] Chinese Peoples Liberat Army Gen Hosp, Dept Intervent Ultrasound, Beijing, Peoples R China
[4] Sun Yat Sen Univ, Affiliated Hosp 1, Dept Liver Surg, Guangzhou, Guangdong, Peoples R China
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2018年 / 44卷 / 09期
关键词
Irreversible electroporation ablation; Contrast-enhanced ultrasound; Pancreatic adenocarcinoma; Imaging; Tumor response; PORCINE LIVER; US FINDINGS; TUMORS; CANCER; SAFETY; MRI;
D O I
10.1016/j.ultrasmedbio.2018.05.018
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The objective was to evaluate the diagnostic value of contrast-enhanced ultrasound in the assessment of the local efficacy after irreversible electroporation (IRE) ablation of pancreatic adenocarcinoma 1 mo after ablation. Fifteen patients with pancreatic adenocarcinoma were treated with IRE and then examined by contrast-enhanced ultrasound 1 mo after ablation. The contrast agent was SonoVue. Technical efficacy was assessed at 3 mo after IRE and classified as technical efficiency (TE) and technical inefficiency (TIE). Diagnostic performance was analyzed using a receiver operating characteristic curve. Ten patients were considered as having TE, and five, TIE. Complete non-enhancement was observed in seven ablation zones (70.0%) in the TE group, and peripheral heterogeneous enhancement, in all five ablation zones (100.0%) in the TIE group. The non-enhancement pattern differed significantly between the TE and TIE groups (p = 0.026), with significant correlation with technical efficacy (p = 0.007). The area under the receiver operating characteristic curve was 0.85 (p = 0.008, 95% confidence interval: 0.65-1.05). A non-enhancement pattern using contrast-enhanced ultrasound was useful in the assessment of local efficacy after IRE ablation of pancreatic adenocarcinoma. (E-mail: kuangm@mail.sysu.edu.cn) (C) 2018 World Federation for Ultrasound in Medicine & Biology. All rights reserved.
引用
收藏
页码:1986 / 1995
页数:10
相关论文
共 50 条
  • [41] Contrast-enhanced ultrasound and contrast-enhanced computed tomography for differentiating mass-forming pancreatitis from pancreatic ductal adenocarcinoma: a meta-analysis
    Yang, Jie
    Huang, Jiayan
    Zhang, Yonggang
    Zeng, Keyu
    Liao, Min
    Jiang, Zhenpeng
    Bao, Wuyongga
    Lu, Qiang
    CHINESE MEDICAL JOURNAL, 2023, 136 (17) : 2028 - 2036
  • [42] Correlation between renal ablation zone in contrast-enhanced CT and non-enhanced MRI during the early period following percutaneous cryoablation
    Umakoshi, Noriyuki
    Iguchi, Toshihiro
    Hiraki, Takao
    Matsui, Yusuke
    Tomita, Koji
    Uka, Mayu
    Kajita, Soichiro
    Araki, Motoo
    Mitsuhashi, Toshiharu
    Gobara, Hideo
    Kanazawa, Susumu
    JAPANESE JOURNAL OF RADIOLOGY, 2022, 40 (10) : 1087 - 1095
  • [43] Dynamic contrast-enhanced MRI of the microenvironment of pancreatic adenocarcinoma xenografts
    Wegner, Catherine S.
    Hauge, Anette
    Gaustad, Jon-Vidar
    Andersen, Lise Mari K.
    Simonsen, Trude G.
    Galappathi, Kanthi
    Rofstad, Einar K.
    ACTA ONCOLOGICA, 2017, 56 (12) : 1754 - 1762
  • [44] TRANSRECTAL HIFU ABLATION OF PROSTATE CANCER: ASSESSMENT OF TISSUE DESTRUCTION WITH CONTRAST-ENHANCED ULTRASOUND
    Rouviere, O.
    Glas, L.
    Girouin, N.
    Mege-Lechevallier, F.
    Gelet, A.
    Chapelon, J. Y.
    Lyonnet, D.
    EUROPEAN UROLOGY SUPPLEMENTS, 2009, 8 (04) : 356 - 356
  • [45] Histological influence on contrast-enhanced CT of pancreatic ductal adenocarcinoma
    Demachi, H
    Matsui, B
    Kobayashi, S
    Akakura, Y
    Konishi, K
    Tsuji, M
    Miwa, A
    Miyata, S
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (06) : 980 - 985
  • [46] Contrast-enhanced versus non-enhanced three-dimensional echocardiography of left ventricular volumes
    J. A. van der Heide
    H. F. J. Mannaerts
    L. Yang
    G. T. Sieswerda
    C. A. Visser
    O. Kamp
    Netherlands Heart Journal, 2008, 16 : 47 - 52
  • [47] Correlation between renal ablation zone in contrast-enhanced CT and non-enhanced MRI during the early period following percutaneous cryoablation
    Noriyuki Umakoshi
    Toshihiro Iguchi
    Takao Hiraki
    Yusuke Matsui
    Koji Tomita
    Mayu Uka
    Soichiro Kajita
    Motoo Araki
    Toshiharu Mitsuhashi
    Hideo Gobara
    Susumu Kanazawa
    Japanese Journal of Radiology, 2022, 40 : 1087 - 1095
  • [48] The efficacy of combination of induction chemotherapy and irreversible electroporation ablation for patients with locally advanced pancreatic adenocarcinoma
    Huang, Kai-Wen
    Yang, Po-Chih
    Pua, Uei
    Kim, Man-Deuk
    Li, Sheng-Ping
    Qiu, Yu-Dong
    Song, Tian-Qiang
    Liang, Po-Chin
    JOURNAL OF SURGICAL ONCOLOGY, 2018, 118 (01) : 31 - 36
  • [49] Assessment of tumour angiogenesis using Contrast-Enhanced Ultrasound
    Cosgrove, D.
    Lassau, N.
    JOURNAL DE RADIOLOGIE, 2009, 90 (01): : 156 - 164
  • [50] Assessment of subclinical atherosclerosis using contrast-enhanced ultrasound
    van den Oord, Stijn C. H.
    ten Kate, Gerrit L.
    Akkus, Zeynettin
    Renaud, Guillaume
    Sijbrands, Eric J. G.
    ten Cate, Folkert J.
    van der Lugt, Aad
    Bosch, Johan G.
    de Jong, Nico
    van der Steen, Antonius F. W.
    Schinkel, Arend F. L.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2013, 14 (01) : 56 - 61