Diagnostic value of implantable loop recorders in patients with unexplained syncope or palpitations

被引:3
|
作者
Radovanovic, Nikola N. [1 ]
Pavlovic, Sinisa U. [1 ,2 ]
Kircanski, Bratislav [1 ,2 ]
Brankovic, Nemanja [1 ]
Vujadinovic, Nikola [1 ]
Sajic, Vojislav [1 ]
Milasinovic, Ana [1 ]
Bisenic, Vesna [1 ]
Zivkovic, Mirjana [1 ]
Milasinovic, Goran [1 ,2 ]
机构
[1] Clin Ctr Serbia, Pacemaker Ctr, Belgrade, Serbia
[2] Univ Belgrade, Fac Med, Belgrade, Serbia
关键词
arrhythmia; implantable loop recorder; palpitations; syncope; CLINICAL-PRACTICE; GUIDELINES; MANAGEMENT; PREDICTORS; SYMPTOMS; YIELD;
D O I
10.1111/anec.12864
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The implantable loop recorder (ILR) is a small cardiac rhythm-monitoring device. Our aim was to determine ILR diagnostic value in patients with unexplained syncope, presyncope, or palpitations suggesting cardiac arrhythmias. Methods This has been a retrospective, observational, single-center study. We included 181 patients in whom ILR was implanted at the Clinical Center of Serbia between January 2006 and July 2019. An event was marked as diagnostic if it led to a diagnosis and ILR was considered diagnostic if it verified or excluded an arrhythmia as the cause of syncope or palpitations. Results The mean age was 51.8 +/- 17.8 years and 94 (51.9%) were male. The mean follow-up period was 20.2 +/- 15.8 months. ILR was diagnostic in 98 patients (54.1%). There was no significant difference in diagnostic value of ILR in regard to the baseline patients' characteristics. The mean time to occurrence of the diagnostic event was 11.1 +/- 9.6 months. The time to occurrence of a diagnostic event did not differ significantly between patients who underwent basic as compared to extended diagnostics before ILR implantation. Conclusions ILR was able to achieve an etiological diagnosis in 54.1% of patients with unexplained syncope, presyncope, or palpitations suggesting cardiac arrhythmias. In a subgroup of patients with recurrent palpitations, ILR was significantly less diagnostic than in patients with syncope or presyncope. ILR should be implanted beforehand in syncope evaluation process.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Unexplained syncope: What to expect from loop recorders
    Porterfield, JG
    Porterfield, LM
    [J]. HEARTWEB, 1998, 4 (01):
  • [32] Use of the implantable loop recorder in evaluation of patients with unexplained syncope
    Krahn, AD
    Klein, GJ
    Skanes, AC
    Yee, R
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2003, 14 (09) : S70 - S73
  • [33] High diagnostic yield associated with the use of an implantable loop recorder in the investigation of syncope and palpitations
    Roberts, PR
    Stuart, A
    Timothy, BR
    Butler, A
    Morgan, JM
    [J]. CIRCULATION, 2000, 102 (18) : 827 - 828
  • [34] Initial experience with an implantable loop recorder in patients with unexplained syncope
    Seidl, K
    Breunung, S
    Rameken, M
    Siemon, G
    Schwacke, H
    Drögemüller, A
    Zahn, R
    Senges, J
    [J]. ZEITSCHRIFT FUR KARDIOLOGIE, 2000, 89 (01): : 43 - 50
  • [35] Diagnostic Yield and Clinical Implications of Implantable Loop Recorders in Patients with Syncope in Germany: A National Database Analysis
    Mueller-Leisse, Johanna
    Hillmann, Henrike Aenne Katrin
    Iserloh, Laura
    Fruehauf, Bjoern
    Duncker, David
    [J]. JOURNAL OF CLINICAL MEDICINE, 2024, 13 (06)
  • [36] Predictors of pacemaker requirement in patients receiving implantable loop recorders for unexplained syncope: A systematic review and meta-analysis
    William, Jeremy
    Nanayakkara, Shane
    Chieng, David
    Sugumar, Hariharan
    Ling, Liang-Han
    Patel, Hitesh
    Mariani, Justin
    Prabhu, Sandeep
    Kistler, Peter M.
    Voskoboinik, Aleksandr
    [J]. HEART RHYTHM, 2024, 21 (09) : 1703 - 1710
  • [37] The Value of the Implantable Loop Recorder in Patients with Syncope
    Schernthaner, Ch.
    Strohmer, B.
    Pichler, M.
    [J]. JOURNAL FUR KARDIOLOGIE, 2005, 12 : 8 - 10
  • [38] Incremental value of implantable loop recorders in patients with cardiomyopathies
    Viegas, J. M. Jose Miguel
    Cardoso, I.
    Bras, P. G.
    Antunes, M.
    Rosa, S. A.
    Portugal, G.
    Lousinha, A.
    Cunha, P. S.
    Oliveira, M.
    Ferreira, R. C.
    [J]. EUROPEAN JOURNAL OF HEART FAILURE, 2023, 25 : 357 - 357
  • [39] External loop recorders: Determinants of diagnostic yield in patients with syncope
    Gula, LJ
    Krahn, AD
    Massel, D
    Skanes, A
    Yee, R
    Klein, GJ
    [J]. AMERICAN HEART JOURNAL, 2004, 147 (04) : 644 - 648
  • [40] Tilt Table Testing and Implantable Loop Recorders for Syncope
    Sheldon, Robert
    [J]. CARDIOLOGY CLINICS, 2013, 31 (01) : 67 - 74