Diagnostic value of implantable loop recorders in patients with unexplained syncope or palpitations

被引:3
|
作者
Radovanovic, Nikola N. [1 ]
Pavlovic, Sinisa U. [1 ,2 ]
Kircanski, Bratislav [1 ,2 ]
Brankovic, Nemanja [1 ]
Vujadinovic, Nikola [1 ]
Sajic, Vojislav [1 ]
Milasinovic, Ana [1 ]
Bisenic, Vesna [1 ]
Zivkovic, Mirjana [1 ]
Milasinovic, Goran [1 ,2 ]
机构
[1] Clin Ctr Serbia, Pacemaker Ctr, Belgrade, Serbia
[2] Univ Belgrade, Fac Med, Belgrade, Serbia
关键词
arrhythmia; implantable loop recorder; palpitations; syncope; CLINICAL-PRACTICE; GUIDELINES; MANAGEMENT; PREDICTORS; SYMPTOMS; YIELD;
D O I
10.1111/anec.12864
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The implantable loop recorder (ILR) is a small cardiac rhythm-monitoring device. Our aim was to determine ILR diagnostic value in patients with unexplained syncope, presyncope, or palpitations suggesting cardiac arrhythmias. Methods This has been a retrospective, observational, single-center study. We included 181 patients in whom ILR was implanted at the Clinical Center of Serbia between January 2006 and July 2019. An event was marked as diagnostic if it led to a diagnosis and ILR was considered diagnostic if it verified or excluded an arrhythmia as the cause of syncope or palpitations. Results The mean age was 51.8 +/- 17.8 years and 94 (51.9%) were male. The mean follow-up period was 20.2 +/- 15.8 months. ILR was diagnostic in 98 patients (54.1%). There was no significant difference in diagnostic value of ILR in regard to the baseline patients' characteristics. The mean time to occurrence of the diagnostic event was 11.1 +/- 9.6 months. The time to occurrence of a diagnostic event did not differ significantly between patients who underwent basic as compared to extended diagnostics before ILR implantation. Conclusions ILR was able to achieve an etiological diagnosis in 54.1% of patients with unexplained syncope, presyncope, or palpitations suggesting cardiac arrhythmias. In a subgroup of patients with recurrent palpitations, ILR was significantly less diagnostic than in patients with syncope or presyncope. ILR should be implanted beforehand in syncope evaluation process.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] The usefullness of implantable loop recorders for evaluation of unexplained syncope and palpitations
    Kristjansdottir, I
    Reimarsdottir, G.
    Arnar, D. O.
    [J]. LAEKNABLADID, 2012, 98 (09): : 465 - 468
  • [2] Implantable Loop Recorders in Patients with Unexplained Syncope: Does Ethnic Background Influence Diagnostic Yield?
    Halabi, Majdi
    Drimer-Shabtai, Hagar
    Rosenfeld, Inna
    Sharabi-Nov, Adi
    Saad, Mussa
    Marai, Ibrahim
    Abuiznait, Ziad
    Armon-Omer, Ayelet
    Regev-Avraham, Zippi
    Israeli, Zeev
    [J]. ISRAEL MEDICAL ASSOCIATION JOURNAL, 2023, 25 (06): : 426 - 429
  • [3] Diagnostic yield of implantable loop recorders in patients with unexplained syncope: single-center experience
    Kajdic, Nina
    Meznar, Anja Zupan
    Sinkovec, Matjaz
    Zizek, David
    [J]. MINERVA CARDIOLOGY AND ANGIOLOGY, 2021, 69 (04) : 419 - 425
  • [4] Implantable loop recorders in older persons with unexplained syncope
    Seifer, C.
    Liebrecht, K.
    Daba, L.
    [J]. EUROPEAN HEART JOURNAL, 2011, 32 : 300 - 301
  • [5] Atrial fibrillation in elderly patients with implantable loop recorders for unexplained syncope
    Arcinas, Liane A.
    McIntyre, William F.
    Hayes, Christopher J.
    Ibrahim, Omar A.
    Baranchuk, Adrian M.
    Seifer, Colette M.
    [J]. ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2019, 24 (03)
  • [6] Do implantable loop recorders impact the survival of patients with recurrent unexplained syncope?
    Perings, Christian
    Wolff, Claudia
    Wilk, Adrian
    Witthohn, Andreas
    Voss, Rainer
    Rybak, Karin
    [J]. JOURNAL OF COMPARATIVE EFFECTIVENESS RESEARCH, 2021, 10 (04) : 285 - 294
  • [7] Implantable loop recorders in patients with unexplained syncope: Clinical predictors of pacemaker implantation
    Huemer, Martin
    Becker, Ann-Kristin
    Wutzler, Alexander
    Attanasio, Philipp
    Parwani, Abdul
    Lacour, Philipp
    Boldt, Leif-Hendrik
    Pieske, Burkert
    Haverkamp, Wilhelm
    Blaschke, Florian
    [J]. CARDIOLOGY JOURNAL, 2019, 26 (01) : 36 - 46
  • [8] Evaluation of the diagnostic value of an implantable loop recorder in dogs with unexplained syncope
    Santilli, Roberto A.
    Ferasin, Luca
    Voghera, Simona G.
    Perego, Manuela
    [J]. JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2010, 236 (01): : 78 - 82
  • [9] Diagnostic value of implantable loop recorders
    Mitra, R.
    Rees, P.
    Anderson, M.
    [J]. EUROPEAN HEART JOURNAL, 2005, 26 : 739 - 739
  • [10] The diagnostic yield of implantable loop recorders in unexplained syncope: A systematic review and meta-analysis
    Solbiati, Monica
    Casazza, Giovanni
    Dipaola, Franca
    Barbic, Franca
    Caldato, Maja
    Montano, Nicola
    Furlan, Raffaello
    Sheldon, Robert S.
    Costantino, Giorgio
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 231 : 170 - 176