Predicting the circumferential strains on a cylindrical concrete specimen during a pull-out test

被引:3
|
作者
Leibovich, Orit [1 ,2 ]
Yankelevsky, David Z. [3 ]
Dancygier, Avraham N. [4 ]
机构
[1] Sami Shamoon Coll Engn, Ashdod, Israel
[2] Technion Israel Inst Technol, Natl Bldg Res Inst, Haifa, Israel
[3] Technion Israel Inst Technol, Struct Engn, Fac Civil & Environm Engn, Natl Bldg Res Inst, Haifa, Israel
[4] Technion Israel Inst Technol, Fac Civil & Environm Engn, Struct Engn, IL-32000 Haifa, Israel
关键词
bond; circumferential strain; pull‐ out test; ring action; theoretical analysis | shear zone |3‐ D behavior;
D O I
10.1002/suco.202000642
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In a recent experimental research, the authors measured the circumferential strains on the cylindrical envelope of concrete specimens during pull-out tests. This paper presents a theoretical approach, complementing the previous experimental study, aiming at predicting these measured circumferential strains and developing the understanding of the three-dimensional behavior of the concrete cylinder. The proposed approach accounts for the specimen materials and geometrical parameters including the ribs and strain gauges locations and proposes an expression for the normalized and absolute circumferential strains along the specimen circumference due to ribs actions. This paper presents a new three-dimensional model of the specimen behvior during a pull-out test, which provides new insight on bond mechanics and illuminates the role of the radial pressures developed as part of the bond action. Several simulations were performed on specimens with three different diameters, two concrete strengths, and a different number of bonded ribs. All the simulations show very good agreement with the measured strain data. This study enhances the understanding of bond resistance during a pull-out process and contributes to the understanding of the ring action that is developed in a concrete cylinder during a pull-out test.
引用
收藏
页码:3026 / 3041
页数:16
相关论文
共 50 条
  • [42] Study on bond-slip between reinforcing bar and concrete during transient pull-out test under fire
    Liu, Caiwei
    Qiu, Ziwen
    Wu, Qingdong
    Yan, Liangtai
    Han, Yanqing
    Miao, Jijun
    Ba, Panfeng
    STRUCTURES, 2024, 61
  • [43] Stress distributions during fiber pull-out
    Department of Mechanical Engineering, Indian Institute of Technology, Madras, 600036, India
    不详
    J Appl Mech Trans ASME, 2 (301-306):
  • [44] NONLINEAR FINITE ELEMENT ANALYSIS OF PULL-OUT TEST
    Ottosen, Niels Saabye
    1981, 107 (04): : 591 - 603
  • [45] Pull-out test of FRP anchors in clay bricks
    Tao, Y.
    Zheng, X. L.
    Shi, Q. X.
    Chen, J. F.
    INSIGHTS AND INNOVATIONS IN STRUCTURAL ENGINEERING, MECHANICS AND COMPUTATION, 2016, : 1512 - 1517
  • [46] Stress distributions during fiber pull-out
    Kumar, RK
    Reddy, JN
    JOURNAL OF APPLIED MECHANICS-TRANSACTIONS OF THE ASME, 1996, 63 (02): : 301 - 306
  • [47] Comparison of Crack Propagation Analyses in a Pull-Out Test
    Gontarz, Jakub
    Podgorski, Jerzy
    Siegmund, Michal
    COMPUTER METHODS IN MECHANICS (CMM2017), 2018, 1922
  • [48] Pull-out Test of Longitudinal Joints of Shield Tunnel
    Geng P.
    Wang Q.
    Guo X.-Y.
    Zeng G.-X.
    Chen C.-J.
    He C.
    Zhongguo Gonglu Xuebao/China Journal of Highway and Transport, 2020, 33 (07): : 124 - 134
  • [49] Study of the Influence of Vertical Pressure on Pull-out Test
    Geng Min
    Dou Yuanming
    CIVIL ENGINEERING IN CHINA - CURRENT PRACTICE AND RESEARCH REPORT: PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON CIVIL ENGINEERING, 2011, : 13 - 17
  • [50] Numerical simulation of pull-out test on cable bolts
    Singh, Shikha
    Srivastava, A. K.
    MATERIALS TODAY-PROCEEDINGS, 2021, 45 : 6332 - 6340