Beam test results of CMS RPCs at high eta region under high-radiation environment

被引:19
|
作者
Park, S
Ahn, SH
Bahk, SY
Hong, B
Hong, SJ [1 ]
Kang, DH
Kang, TI
Kim, TJ
Kim, YJ
Kim, YU
Koo, DG
Lee, HW
Lee, KS
Lee, SJ
Lim, JK
Moon, DH
Nam, SK
Oh, JK
Park, WJ
Rhee, JT
Ryu, MS
Shim, HH
Sim, KS
机构
[1] Korea Univ, Dept Phys, Seoul 136701, South Korea
[2] Korea Univ, Korea Detector Lab, Seoul 136701, South Korea
[3] Wonkwang Univ, Dept Phys, Iksan 570749, South Korea
[4] Cheju Natl Univ, Dept Phys, Cheju 690756, South Korea
[5] Chungbuk Natl Univ, Dept Phys, Chungju 361763, South Korea
[6] Seoul Natl Univ Educ, Dept Phys, Seoul 137742, South Korea
[7] Seonam Univ, Dept Biomed Engn, Namwon 590711, South Korea
[8] Kangweon Natl Univ, Dept Phys, Chunchon 200701, South Korea
[9] Konkuk Univ, Inst Adv Phys, Seoul 143701, South Korea
关键词
non-oiled RPC; oiled RPC; CMS; LHC; melamine; phenolic;
D O I
10.1016/j.nima.2004.06.125
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Compact Muon Solenoid (CMS) forward resistivity plate chambers (RPCs) at the high eta region must be operated in presence of a radiation-induced rate as high as 1 kHz/cm(2). It is still unknown if the RPCs coated with linseed oil can be operated under such a high-radiation environment over the lifetime of CMS. Non-oiled RPCs may be one of the options since phenolic or melamine-coated bakelite is chemically stabler than linseed oil. We have constructed oiled and non-oiled RPCs at the high eta region of CMS using phenolic bakelite and tested them in the Gamma Irradiation Facility at CERN. While both RPCs show the same characteristics in the efficiency and the strip multiplicity, the non-oiled RPC generates an intrinsic noise rate of 50 Hz/cm(2), compared to only 5 Hz/cm(2) for the oiled RPC, both at 10.0 kV which is about 100 V above the 95% knee of the efficiency curve. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:37 / 41
页数:5
相关论文
共 50 条
  • [31] Precision Crystal Calorimetry at High Energy and High Luminosity: CMS ECAL Performance at 13 TeV and Upgrade Test Beam Studies
    Micheli, F.
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [32] Testing of high rate digital links under radiation environment
    Lemoine, G
    Nodet, J
    Ecoffet, R
    DATA SYSTEMS IN AEROSPACE - PROCEEDINGS, 1998, : 87 - 93
  • [33] First beam test results with Micromegas, a high-rate, high-resolution detector
    Charpak, G.
    Derre, J.
    Giganon, A.
    Giomataris, Y.
    Jourde, D.
    Kochowski, C.
    Loucatos, S.
    Puill, G.
    Rebourgeard, Ph.
    Robert, J.P.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1998, 412 (01): : 47 - 60
  • [34] First beam test results with Micromegas, a high-rate, high-resolution detector
    Charpak, G
    Derre, J
    Giganon, A
    Giomataris, Y
    Jourde, D
    Kochowski, C
    Loucatos, S
    Puill, G
    Rebourgeard, P
    Robert, JP
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 412 (01): : 47 - 60
  • [35] Test beam evaluation of newly developed n-in-p planar pixel sensors for use in a high radiation environment
    Kimura, K.
    Yamaguchi, D.
    Motohashi, K.
    Nakamura, K.
    Unno, Y.
    Jinnouchi, O.
    Altenheiner, S.
    Blue, A.
    Bomben, M.
    Butter, A.
    Cervelli, A.
    Crawley, S.
    Ducourthial, A.
    Gisen, A.
    Hagihara, M.
    Hanagaki, K.
    Hara, K.
    Hirose, M.
    Homma, Y.
    Ikegami, Y.
    Kamada, S.
    Kono, T.
    Macchiolo, A.
    Marchiori, G.
    Meloni, F.
    Milovanovic, M.
    Morton, A.
    Mullier, G.
    Munoz, F. J.
    Nellist, C.
    Paschen, B.
    Quadt, A.
    Rashid, T.
    Rieger, J.
    Rummler, A.
    Sato, K.
    Sato, K.
    Savic, N.
    Sawai, H.
    Sexton, K.
    Stramaglia, M. E.
    Swiatlowski, M.
    Takashima, R.
    Takubo, Y.
    Terzo, S.
    Todome, K.
    Tojo, J.
    Van Houten, K.
    Weingarten, J.
    Wonsak, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 831 : 140 - 146
  • [36] Test beam results of a high granularity LuAG fibre calorimeter prototype
    Benaglia, A.
    Lucchini, M.
    Pauwels, K.
    Tully, C.
    Medvedeva, T.
    Heering, A.
    Dujardin, C.
    Kononets, V.
    Lebbou, K.
    Aubry, N.
    Faraj, S.
    Ferro, G.
    Lecoq, P.
    Auffray, E.
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [37] Applications of cerium-doped gadolinium silicate Gd2SiO5:Ce scintillator to calorimeters in high-radiation environment
    Tanaka, M
    Hara, K
    Kim, S
    Kondo, K
    Takano, H
    Kobayashi, M
    Ishibashi, H
    Kurashige, K
    Susa, K
    Ishii, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 404 (2-3): : 283 - 294
  • [38] Performance Evaluation of Polybenzimidazole Under High-Energy Radiation Environment
    Iqbal, H. M. S.
    Bhowmik, S.
    Benedictus, R.
    JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2016, 30 (04) : 825 - 830
  • [39] Beam test results of a high-granularity tile/fiber electromagnetic calorimeter
    Ono, H.
    Miyata, H.
    Iba, S.
    Nakajima, N.
    Sanchez, A. L. C.
    Fujii, Y.
    Itoh, S.
    Kajino, F.
    Kanzaki, J.
    Kawagoe, K.
    Kim, S.
    Kishimoto, S.
    Matsumoto, T.
    Matsunaga, H.
    Nagano, A.
    Nakamura, R.
    Takeshita, T.
    Tamura, Y.
    Yamauchi, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 600 (02): : 398 - 407
  • [40] Noise of CIS Effect on Imaging Resolution of Camera under High Radiation Environment
    Wang H.
    Feng J.
    Li Y.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2022, 56 (04): : 775 - 782