Beam test results of CMS RPCs at high eta region under high-radiation environment

被引:19
|
作者
Park, S
Ahn, SH
Bahk, SY
Hong, B
Hong, SJ [1 ]
Kang, DH
Kang, TI
Kim, TJ
Kim, YJ
Kim, YU
Koo, DG
Lee, HW
Lee, KS
Lee, SJ
Lim, JK
Moon, DH
Nam, SK
Oh, JK
Park, WJ
Rhee, JT
Ryu, MS
Shim, HH
Sim, KS
机构
[1] Korea Univ, Dept Phys, Seoul 136701, South Korea
[2] Korea Univ, Korea Detector Lab, Seoul 136701, South Korea
[3] Wonkwang Univ, Dept Phys, Iksan 570749, South Korea
[4] Cheju Natl Univ, Dept Phys, Cheju 690756, South Korea
[5] Chungbuk Natl Univ, Dept Phys, Chungju 361763, South Korea
[6] Seoul Natl Univ Educ, Dept Phys, Seoul 137742, South Korea
[7] Seonam Univ, Dept Biomed Engn, Namwon 590711, South Korea
[8] Kangweon Natl Univ, Dept Phys, Chunchon 200701, South Korea
[9] Konkuk Univ, Inst Adv Phys, Seoul 143701, South Korea
关键词
non-oiled RPC; oiled RPC; CMS; LHC; melamine; phenolic;
D O I
10.1016/j.nima.2004.06.125
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Compact Muon Solenoid (CMS) forward resistivity plate chambers (RPCs) at the high eta region must be operated in presence of a radiation-induced rate as high as 1 kHz/cm(2). It is still unknown if the RPCs coated with linseed oil can be operated under such a high-radiation environment over the lifetime of CMS. Non-oiled RPCs may be one of the options since phenolic or melamine-coated bakelite is chemically stabler than linseed oil. We have constructed oiled and non-oiled RPCs at the high eta region of CMS using phenolic bakelite and tested them in the Gamma Irradiation Facility at CERN. While both RPCs show the same characteristics in the efficiency and the strip multiplicity, the non-oiled RPC generates an intrinsic noise rate of 50 Hz/cm(2), compared to only 5 Hz/cm(2) for the oiled RPC, both at 10.0 kV which is about 100 V above the 95% knee of the efficiency curve. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:37 / 41
页数:5
相关论文
共 50 条
  • [1] Test of CMS barrel muon drift chambers in high-radiation environment
    Wegner, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 461 (1-3): : 115 - 117
  • [2] Aging study with high-level radiation sources for the CMS forward RPCs
    Kim, H. C.
    Hu, R. J.
    Ahn, S. H.
    Hong, B.
    Kim, B. I.
    Kim, C.
    Kim, J. H.
    Kim, T. J.
    Lee, K. B.
    Lee, K. S.
    Lim, J. K.
    Moon, D. H.
    Park, S. K.
    Ryu, M. S.
    Sim, K. S.
    Won, E.
    Bahk, S. Y.
    Hong, S. J.
    Kim, Y. J.
    Kim, Y. U.
    Koo, D. G.
    Lee, S. J.
    Nam, S. K.
    Rhee, J. T.
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2008, 52 (03) : 913 - 919
  • [3] VACUUM SYSTEM FOR HIGH-RADIATION ENVIRONMENT AT RPI LINAC LABORATORY
    HAKEN, J
    LEWIS, JF
    KRASSE, RJ
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY, 1969, 6 (01): : 202 - &
  • [4] Test beam measurements of the CMS High Granularity Calorimeter
    Choudhury, S.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (01):
  • [5] Design and operation of a fast high-granularity silicon detector system in a high-radiation environment
    Alessandro, B
    Alexeline, M
    Baglin, C
    Beole, S
    Bollito, E
    Bonazzola, G
    Bussiere, A
    Capony, V
    Dabrowski, W
    De Remigis, P
    De Witt, J
    Forlen, M
    Giubellino, P
    Idzik, M
    Marzari-Chiesa, A
    Masera, M
    da Silva, WP
    Ramello, L
    Mendes, PR
    Riccati, L
    Sartori, MS
    Sitta, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 409 (1-3): : 167 - 172
  • [6] High energy beam impact tests on a LHC tertiary collimator at the CERN high-radiation to materials facility
    Cauchi, Marija
    Aberle, O.
    Assmann, R. W.
    Bertarelli, A.
    Carra, F.
    Cornelis, K.
    Dallocchio, A.
    Deboy, D.
    Lari, L.
    Redaelli, S.
    Rossi, A.
    Salvachua, B.
    Mollicone, P.
    Sammut, N.
    PHYSICAL REVIEW SPECIAL TOPICS-ACCELERATORS AND BEAMS, 2014, 17 (02):
  • [7] The performance of RPCs with bakelite electrodes of various resistivity under high radiation fluxes
    Cwiok, M
    Dominik, W
    Górski, M
    Królikowski, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 456 (1-2): : 87 - 90
  • [8] Performance of a large forward resistive plate chamber for the CMS/LHC under high radiation environment
    Ahn, SH
    Amirikas, R
    Bahk, SY
    Hong, B
    Hong, SJ
    Kim, KH
    Kim, YJ
    Kim, YU
    Koo, DG
    Lee, KS
    Lee, SJ
    Nam, SK
    Park, S
    Rhee, JT
    Seo, SW
    Sim, KS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 469 (03): : 323 - 330
  • [9] Operation of the prospective beamline calorimeter in the high-radiation forward environment of the international linear collider
    Schumm, Bruce A.
    Smithers, Benjamin
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 908 : 198 - 205
  • [10] Forward-bias operation of Si detectors: a way to work in high-radiation environment
    Beattie, LJ
    Chilingarov, A
    Sloan, T