Convective condensation at low mass flux: Effect of turbulence and tube orientation on the heat transfer

被引:25
|
作者
Azzolin, Marco [1 ]
Bortolin, Stefano [1 ]
Del Col, Davide [1 ]
机构
[1] Univ Padua, Dept Ind Engn, Via Venezia 1, I-35131 Padua, Italy
关键词
TRANSFER COEFFICIENTS; REGIME TRANSITIONS; PRESSURE-DROP; FLOW; INCLINATION; MINICHANNEL; CHANNELS; LAMINAR; MODEL;
D O I
10.1016/j.ijheatmasstransfer.2019.118646
中图分类号
O414.1 [热力学];
学科分类号
摘要
It is well proved in the literature that gravity affects in-tube condensation heat transfer at low mass flux. Nevertheless very limited data are taken at low mass flux when changing tube orientation, despite the many practical applications. In this paper, convective condensation inside a 3.4 mm inner diameter tube is investigated in horizontal and vertical downflow using R134a as the working fluid. The experiments are performed at low mass flux, between 50 kg m(-2) s(-1) and 200 kg m(-2) s(-1), which are usually the less investigated despite the relevance of gravity force at such low velocities. The condensation heat transfer coefficient in vertical downflow can be as low as half the value in horizontal flow at the same operating conditions, since gravity acts for the thinning of the liquid film in the horizontal tube. In vertical downflow, the heat transfer coefficients show an early effect of turbulence, thus a new transition criterion is here proposed. Criteria for predicting the relevance of channel orientation on the heat transfer coefficient are also assessed. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Mechanism Research of Convective Condensation Heat Transfer for a Gas Mixture Flowing over a Horizontal Tube
    Jia, Li
    Wu, Dongmei
    Qi, Wei
    HEAT TRANSFER-ASIAN RESEARCH, 2009, 38 (02): : 83 - 91
  • [42] Analysis of convective condensation heat transfer for moist air on a three-dimensional finned tube
    Gu, Yuheng
    Ding, Yudong
    Liao, Qiang
    Fu, Qian
    Zhu, Xun
    Wang, Hong
    APPLIED THERMAL ENGINEERING, 2021, 195 (195)
  • [43] The effect of burner orientation on the convective heat transfer rate in a round furnace
    Jain, P
    Kiss, LI
    Charette, A
    Bui, RT
    Bourgeois, T
    Stevens, W
    CANADIAN METALLURGICAL QUARTERLY, 1998, 37 (3-4) : 323 - 332
  • [44] Effect of EHD on heat transfer enhancement during two-phase condensation of R-134a at high mass flux in a horizontal smooth tube
    Laohalertdecha, Suriyan
    Wongwises, Somchai
    HEAT AND MASS TRANSFER, 2007, 43 (09) : 871 - 880
  • [45] Effect of EHD on heat transfer enhancement during two-phase condensation of R-134a at high mass flux in a horizontal smooth tube
    Suriyan Laohalertdecha
    Somchai Wongwises
    Heat and Mass Transfer, 2007, 43 : 871 - 880
  • [46] Research on heat transfer characteristics of steam condensation with non-condensable gas at low steam mass flux
    Zhang, Dandi
    Li, Shu
    Tong, Lili
    Cao, Xuewu
    APPLIED THERMAL ENGINEERING, 2024, 256
  • [47] Effect of Fouling on Heat Transfer in Convective Boiler Tube Banks.
    Pronobis, M.
    VGB-Kraftwerkstechnik, 1986, 66 (02): : 120 - 127
  • [48] Experimental study on condensation heat transfer characteristics of low mass flow rate steam in a vacuum horizontal tube
    Gu Y.
    Gong L.
    Guo Y.
    Shen S.
    Huagong Xuebao/CIESC Journal, 2022, 73 (02): : 595 - 603
  • [49] Unified formulation of convective heat flux and mass flux vectors with thermodynamic coupling and related transfer coefficients
    Zhao, Bo
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2023, 188
  • [50] Vertical-length effect on dropwise condensation heat transfer at low heat flux - Part I: Experimental study
    Kim, Taeseok
    Kim, Sung Joong
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2024, 224