Three-dimensional analysis of delineation errors, setup errors, and organ motion during radiotherapy of bladder cancer

被引:135
|
作者
Meijer, GJ [1 ]
Rasch, C [1 ]
Remeijer, P [1 ]
Lebesque, JV [1 ]
机构
[1] Antoni Van Leeuwenhoek Huis, Netherlands Canc Inst, Dept Radiotherapy, Amsterdam, Netherlands
关键词
bladder cancer; margin widths; conformal radiotherapy;
D O I
10.1016/S0360-3016(02)04162-7
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To quantify in three dimensions the geometric uncertainties of bladder irradiation (i.e., uncertainties in target delineation, organ motion, and patient setup). Methods and Materials: Pelvic CT images were obtained for 10 male bladder cancer patients. Apart from the initial planning CT scan, three follow-up scans were made for each of the patients. The bladder volumes in the planning CT scan were outlined by seven radiation oncologists. One observer also delineated the bladder volumes in the follow-up scans. Two-dimensional scalar maps of the interobserver variation and organ motion of the bladder surfaces were constructed. The setup errors were derived from the portal imaging results of the pooled group of bladder and prostate patients. Results: All bladder volumes were consistently outlined by all observers. Generally small variations occurred (1.5-3 mm, 1 SD), although in 50% of the patients, larger discrepancies were observed in discriminating the bladder from the base of the prostate. Analysis of the portal imaging data showed setup errors of up to 3 mm (1 SD). Organ motion is the predominant geometric uncertainty in the radiotherapy process (5 min, 1 SD, at the cranial side of the bladder), although 9 of 10 patients were able to preserve a fairly reproducible bladder volume during the complete treatment course. Conclusion: Anisotropie margins between the clinical target volume and planning target volume are needed in conformal radiotherapy of the bladder. Especially at the cranial side of the bladder, larger margins are needed because of the impact of bladder shape variation. (C) 2003 Elsevier Science Inc.
引用
收藏
页码:1277 / 1287
页数:11
相关论文
共 50 条
  • [31] Evaluation of Rotational Errors in Treatment Setup of Stereotactic Body Radiotherapy (SBRT) of Lung Cancer
    Cao, M.
    Lasley, F.
    Fakiris, A.
    Desrosiers, C.
    Das, I.
    MEDICAL PHYSICS, 2011, 38 (06) : 3616 - +
  • [32] Three-dimensional Motion Analysis of the Ankle during Backward Walking
    Soda, Naoki
    Ueki, Tsutomu
    Aoki, Takaaki
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2013, 25 (06) : 747 - 749
  • [33] CT image fusion as a tool for measuring in 3D the setup errors during conformal radiotherapy for prostate cancer
    Cambria, R
    Cattani, F
    Ciocca, M
    Garibaldi, C
    Tosi, G
    Orecchia, R
    TUMORI, 2006, 92 (02) : 118 - 123
  • [34] MR vs CT imaging: low rectal cancer tumour delineation for three-dimensional conformal radiotherapy
    O'Neill, B. D. P.
    Salerno, G.
    Thomas, K.
    Tait, D. M.
    Brown, G.
    BRITISH JOURNAL OF RADIOLOGY, 2009, 82 (978): : 509 - 513
  • [35] Three-dimensional ultrasonographic findings in bladder cancer
    Huang, WC
    Yang, SH
    Yang, JM
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2005, 25 (01) : 92 - 94
  • [36] A Quantitative Theory of Angular Truncation Errors in Three-Dimensional SN Calculations
    Larsen, Edward W.
    Wollaber, Allan B.
    NUCLEAR SCIENCE AND ENGINEERING, 2008, 160 (03) : 267 - 283
  • [37] Evaluating the effects of modeling errors for isolated finite three-dimensional targets
    Henn, Mark-Alexander
    Barnes, Bryan M.
    Zhou, Hui
    JOURNAL OF MICRO-NANOLITHOGRAPHY MEMS AND MOEMS, 2017, 16 (04):
  • [38] Approximation errors and model reduction in three-dimensional diffuse optical tomography
    Kolehmainen, Ville
    Schweiger, Martin
    Nissila, Ilkka
    Tarvainen, Tanja
    Arridge, Simon R.
    Kaipio, Jari P.
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2009, 26 (10) : 2257 - 2268
  • [39] Effects on Three-Dimensional Geosynchronous Circular SAR Imaging by Orbit Errors
    Leilei Kou
    Xiaoqing Wang
    Maosheng Xiang
    Journal of the Indian Society of Remote Sensing, 2014, 42 : 1 - 12
  • [40] Analysis of different fractionations of three-dimensional conformable radiotherapy for esophageal cancer
    Ma, Zhiqian
    Zhang, Yan
    Chen, Xiaofang
    Liu, Chaoxing
    Xu, Huijun
    Zhao, Peng
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (07): : 11139 - 11145