Three-dimensional analysis of delineation errors, setup errors, and organ motion during radiotherapy of bladder cancer

被引:135
|
作者
Meijer, GJ [1 ]
Rasch, C [1 ]
Remeijer, P [1 ]
Lebesque, JV [1 ]
机构
[1] Antoni Van Leeuwenhoek Huis, Netherlands Canc Inst, Dept Radiotherapy, Amsterdam, Netherlands
关键词
bladder cancer; margin widths; conformal radiotherapy;
D O I
10.1016/S0360-3016(02)04162-7
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To quantify in three dimensions the geometric uncertainties of bladder irradiation (i.e., uncertainties in target delineation, organ motion, and patient setup). Methods and Materials: Pelvic CT images were obtained for 10 male bladder cancer patients. Apart from the initial planning CT scan, three follow-up scans were made for each of the patients. The bladder volumes in the planning CT scan were outlined by seven radiation oncologists. One observer also delineated the bladder volumes in the follow-up scans. Two-dimensional scalar maps of the interobserver variation and organ motion of the bladder surfaces were constructed. The setup errors were derived from the portal imaging results of the pooled group of bladder and prostate patients. Results: All bladder volumes were consistently outlined by all observers. Generally small variations occurred (1.5-3 mm, 1 SD), although in 50% of the patients, larger discrepancies were observed in discriminating the bladder from the base of the prostate. Analysis of the portal imaging data showed setup errors of up to 3 mm (1 SD). Organ motion is the predominant geometric uncertainty in the radiotherapy process (5 min, 1 SD, at the cranial side of the bladder), although 9 of 10 patients were able to preserve a fairly reproducible bladder volume during the complete treatment course. Conclusion: Anisotropie margins between the clinical target volume and planning target volume are needed in conformal radiotherapy of the bladder. Especially at the cranial side of the bladder, larger margins are needed because of the impact of bladder shape variation. (C) 2003 Elsevier Science Inc.
引用
收藏
页码:1277 / 1287
页数:11
相关论文
共 50 条
  • [1] CONTROL OF ERRORS USING A SIMPLIFIED CLINICAL SETUP FOR MOTION ANALYSIS: ERRORS DUE TO CALIBRATION AND THREE-DIMENSIONAL RECONSTRUCTION
    Berthonnaud, Eric
    Dimnet, Joannes
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2005, 5 (04) : 491 - 505
  • [2] ROBUST OPTIMIZATION ACCOUNTING FOR ORGAN MOTION, RANGE ERRORS, AND SETUP ERRORS IN IMPT
    Fredriksson, A.
    Hardemark, B.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S100 - S100
  • [3] Automatic detection of device setup errors in radiotherapy by matching three-dimensional CT data and portal images
    Tschirley, R
    Beier, J
    Wust, P
    CARS '99: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1999, 1191 : 270 - 274
  • [4] A study of the effect of setup errors and organ motion on prostate cancer treatment with IMRT
    Landoni, Valeria
    Saracino, Bianca
    Marzi, Siniona
    Gallucci, Michaele
    Petrongari, Maria G.
    Chianese, Enrico
    Benassi, Michaela
    Iaccarino, Giuseppe
    Soriani, Antonella
    Arcangeli, Giorgio
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (02): : 587 - 594
  • [5] An analysis of anatomic landmark mobility and setup errors in radiotherapy for lung cancer
    Samson, MJ
    deKoste, JRV
    deBoer, JCJ
    Tankink, JJ
    Verstraate, MBJ
    Essers, M
    Visser, AG
    Senan, S
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (02): : 319 - 319
  • [6] Measurement of patient positioning errors in three-dimensional conformal radiotherapy of the prostate
    Hanley, J
    Lumley, MA
    Mageras, GS
    Sun, J
    Zelefsky, MJ
    Leibel, SA
    Fuks, Z
    Kutcher, GJ
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 37 (02): : 435 - 444
  • [7] Analysis of inter-fraction setup errors and organ motion by daily kilovoltage cone beam computed tomography in intensity modulated radiotherapy of prostate cancer
    Marcella Palombarini
    Stefano Mengoli
    Paola Fantazzini
    Cecilia Cadioli
    Claudio Degli Esposti
    Giovanni Piero Frezza
    Radiation Oncology, 7
  • [8] Analysis of inter-fraction setup errors and organ motion by daily kilovoltage cone beam computed tomography in intensity modulated radiotherapy of prostate cancer
    Palombarini, Marcella
    Mengoli, Stefano
    Fantazzini, Paola
    Cadioli, Cecilia
    Esposti, Claudio Degli
    Frezza, Giovanni Piero
    RADIATION ONCOLOGY, 2012, 7
  • [9] Assessment of setup errors and internal motion for rectal cancer using MR-guided radiotherapy
    Everaert, T.
    Ruiz, A. Gutierrez
    Kamel, R. Atef
    Bezuidenhout, J. Bodenst
    Smeulders, J.
    Gevaert, T.
    De Ridder, M.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1615 - S1616
  • [10] Analysis of discretization and modeling errors in complex three-dimensional flows
    Visonneau, M
    Schmid, M
    Deng, G
    Peric, M
    NUMERICAL FLOW SIMULATION II, 2001, 75 : 319 - 328