Generating Bipolar nsPulsed Electric Field using Transmission Line & Avalanche Transistors

被引:0
|
作者
Davies, Ilan W. [1 ,2 ]
Hancock, Chris P. [1 ,2 ]
机构
[1] Bangor Univ, Sch Elect Engn & Comp Sci, Bangor, Gwynedd, Wales
[2] Creo Med Grp PLC, Chepstow, Wales
基金
欧盟地平线“2020”;
关键词
avalanche breakdown transistors; transmission lines; nanosecond pulse electric field; biomedical engineering; ELECTROPORATION;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A nanosecond pulse electric field generator based on relatively slow charging and rapid discharging of an open circuit co-axial transmission line through a stack of avalanche transistors operating as a fast switching element, is demonstrated. This low-cost circuit design produces well defined symmetrical bipolar nanosecond pulsed electric fields with rise and fall times less than a nanosecond. The pulse polarity (monopolar negative, monopolar positive or bipolar), duration, repetition rate and amplitude are user controllable. The new pulse generator opens the opportunity for use in a range of medical applications, including tissue sparing tumour ablation, where only the cancerous cells are destroyed.
引用
收藏
页码:1003 / 1006
页数:4
相关论文
共 50 条
  • [31] Analysis on control index of total electric field for DC transmission line
    College of Electrical Engineering, Wuhan University, Wuhan 430072, China
    不详
    不详
    Gaodianya Jishu, 2012, 11 (2843-2847):
  • [32] The Spatial Distribution of Electric Field as a Unifying Idea in Transmission Line Design
    Olsen, Robert G.
    Zhuang, Chijie
    IEEE TRANSACTIONS ON POWER DELIVERY, 2019, 34 (03) : 919 - 928
  • [33] CALCULATING THE ELECTRIC-FIELD OF A 3 PHASE TRANSMISSION-LINE
    KATS, RA
    PERELMAN, LS
    ELECTRICAL TECHNOLOGY, 1978, (01): : 15 - 25
  • [34] Modeling of an ionized electric field on the building near the UHVDC transmission line
    Zhen YongZan
    Cui Xiang
    Lu TieBing
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2014, 57 (04) : 747 - 753
  • [35] ELECTRIC-FIELD OF A TRANSMISSION-LINE OVER MULTILAYERED MEDIA
    MOGHRAM, IS
    TYLAVSKY, DJ
    PROCEEDINGS OF THE IEEE, 1987, 75 (01) : 170 - 171
  • [36] Modeling of an ionized electric field on the building near the UHVDC transmission line
    YongZan Zhen
    Xiang Cui
    TieBing Lu
    Science China Technological Sciences, 2014, 57 : 747 - 753
  • [38] Transient 3D heat flow analysis for high power insulated gate bipolar transistors using the transmission line matrix
    Hocine, R.
    Stambouli, M.A.Boudghene
    Saidane, A.
    International Journal of Microcircuits and Electronic Packaging, 2005, 25 (01): : 132 - 146
  • [39] Transient 3D heat flow analysis for high power insulated gate bipolar transistors using the transmission line matrix
    Hocine, R
    Stambouli, MAB
    Saidane, A
    2002 INTERNATIONAL CONFERENCE ON ADVANCED PACKAGING AND SYSTEMS, PROCEEDINGS, 2002, 4828 : 201 - 206
  • [40] PULSE-GENERATOR USING FIELD-EFFECT AND BIPOLAR-TRANSISTORS
    OBOD, II
    KUTOVOI, IV
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1982, 25 (02) : 379 - 381