Accuracy of a Mobile 2D Imaging System for Body Volume and Subsequent Composition Estimates in a Three-Compartment Model

被引:10
|
作者
Fedewa, Michael V. [1 ]
Sullivan, Katherine [1 ]
Hornikel, Bjoern [1 ]
Holmes, Clifton J. [1 ]
Metoyer, Casey J. [1 ]
Esco, Michael R. [1 ]
机构
[1] Univ Alabama, Dept Kinesiol, Exercise Physiol Lab, Tuscaloosa, AL USA
关键词
FAT MASS; FAT-FREE MASS; BODY FAT PERCENTAGE; UNDERWATER WEIGHING; SMARTPHONE APPLICATION; FAT PERCENTAGE; BIOIMPEDANCE; MEN; SPORT; WOMEN;
D O I
10.1249/MSS.0000000000002550
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Purpose The purpose of the study was to compare a single two-dimensional image processing system (IMAGE) to underwater weighing (UWW) for measuring body volume (BV) and subsequently estimating body fat percentage (%Fat), fat mass (FM), and fat-free mass (FFM) via a 3-compartment (3C) model. Methods A sample of participants age 18-39 yr was recruited for this study (n = 67, 47.8% female). BV was measured with UWW and predicted via the IMAGE software. The BV estimates from UWW (3C(UWW)) and IMAGE (3C(IMAGE)) were separately combined with constant total body water and body mass values for 3C model calculation of %Fat, FM, and FFM. Results BV obtained from the IMAGE was 67.76 +/- 12.19 and 67.72 +/- 12.04 L from UWW, which was not significantly different (P = 0.578) and very largely correlated (r = 0.99, P < 0.001). When converted to %Fat (3C(UWW) = 21.01% +/- 7.30%, 3C(IMAGE) = 21.08% +/- 7.04%, P = 0.775), FM (3C(UWW) = 14.68 +/- 5.15 kg, 3C(IMAGE) = 14.78 +/- 5.08 kg, P = 0.578), and FFM (3C(UWW) = 57.00 +/- 13.20 kg, 3C(IMAGE) = 56.90 +/- 12.84 kg, P = 0.578) with the 3C model, no significant mean differences and very large correlations (r values ranged from 0.96 to 0.99) were observed. In addition, the standard error of estimate, total error, and 95% limits of agreement for all three metrics were small and considered acceptable. Conclusions An IMAGE system provides valid estimates of BV that accurately estimates body composition in a 3C model.
引用
收藏
页码:1003 / 1009
页数:7
相关论文
共 24 条
  • [21] Automated Quantification of Mitral Regurgitation by 3D PISA Using Real Time Three Dimensional Volume Echocardiography: Comparisons with 2D PISA and Magnetic Resonance Imaging
    Heo, Ran
    Chang, Hyuk-Jae
    Lee, Jin-Kyung
    Song, Ran-Young
    Jung, Hee-Jung
    Kim, Young-Jin
    Shim, Chi Young
    Datta, Saurabh
    Hong, Geu-Ru
    Ha, Jong-Won
    Chung, Namsik
    CIRCULATION, 2012, 126 (21)
  • [22] Three-dimensional physics-based registration of pelvic system using 2D dynamic magnetic resonance imaging slices
    Courtecuisse, H.
    Jiang, Z.
    Mayeur, O.
    Witz, J. F.
    Lecomte-Grosbras, P.
    Cosson, M.
    Brieu, M.
    Cotin, S.
    STRAIN, 2020, 56 (03)
  • [23] A 4-COMPARTMENT MODEL OF BODY-COMPOSITION - COMBINING DEUTERIUM DILUTION (D2O) WITH DUAL-ENERGY X-RAY-ABSORPTION (DXA)
    FUSCH, C
    JENSEN, E
    HORBER, F
    PEDIATRIC RESEARCH, 1994, 36 (01) : A14 - A14
  • [24] Numerical study of fluid flow, heat transfer and infrared signature of 2D exhaust system model with full shielded guide vane combined with rear body
    Cheng W.
    Ji H.
    Shi X.
    Wang H.
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2022, 51 (09):