Investigation of indoor and outdoor air quality of the classrooms at a school in Serbia

被引:77
|
作者
Jovanovic, Marina [1 ]
Vucicevic, Biljana [1 ]
Turanjanin, Valentina [1 ]
Zivkovic, Marija [1 ]
Spasojevic, Vuk [1 ]
机构
[1] Univ Belgrade, Inst Nucl Sci Vinca, Lab Thermal Engn & Energy, Belgrade 11001, Serbia
关键词
Classroom air quality; Key indoor air pollutants; School; EXPOSURE; PERFORMANCE; PRODUCTS; CHILDREN; IMPACT;
D O I
10.1016/j.energy.2014.03.080
中图分类号
O414.1 [热力学];
学科分类号
摘要
The air inside schools can be more polluted than the air outside. The purpose of this study was to investigate the air quality in primary school placed in town at the east of Serbia. The characterization of air pollution concentration was performed with main goal to determine relationship between indoor and outdoor air pollution within five classrooms. The measurements were conducted continuously in indoor and outdoor environment for period of 10 days. The standard sampling and analytical methods were applied (gas chromatography coupled with mass spectrometry). This paper presents and analyses concentrations of different physical and chemical pollutants in the indoor and outdoor environment: respirable particulate matter with different diameters (up to 2.5 mu m and 10 mu m), polycyclic aromatic hydrocarbon in particulate matters up to 10 mu m, volatile organic compounds, formaldehyde, ozone, carbon-dioxide and nitric-dioxide. It was found, in one class, that the concentration of particulate matter with diameter up to 10 and 2.5 microns as well as polycyclic aromatic hydrocarbon in particulate matters up to 10 mu m were higher in indoor environment than in outdoor. The average value of formaldehyde in all classrooms was significantly higher than recommended value. On the basis of received results, extensive school renovation program can be recommended. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:42 / 48
页数:7
相关论文
共 50 条
  • [21] Higher Attention Capacity After Improving Indoor Air Quality by Indoor Plant Placement in Elementary School Classrooms
    Kim, Ho-Hyun
    Yeo, In-Young
    Lee, Jae-Young
    [J]. HORTICULTURE JOURNAL, 2020, 89 (03): : 319 - 327
  • [22] COMPARISON OF INDOOR AND OUTDOOR AIR QUALITY.
    Moschandreas, D.J.
    Zabransky, J.
    Pelton, D.J.
    [J]. Electric Power Research Institute (Report) EPRI EA, 1981,
  • [23] Indoor/Outdoor Air Quality Assessment at School near the Steel Plant in Taranto (Italy)
    Di Gilio, A.
    Farella, G.
    Marzocca, A.
    Giua, R.
    Assennato, G.
    Tutino, M.
    de Gennaro, G.
    [J]. ADVANCES IN METEOROLOGY, 2017, 2017
  • [24] Investigation of indoor air quality and indoor/outdoor relationship in three different microenvironments of central part of India
    Lawrence, AJ
    Taneja, A
    [J]. INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 797 - 801
  • [25] A Review on Indoor Environment Quality of Indian School Classrooms
    Kapoor, Nishant Raj
    Kumar, Ashok
    Alam, Tabish
    Kumar, Anuj
    Kulkarni, Kishor S.
    Blecich, Paolo
    [J]. SUSTAINABILITY, 2021, 13 (21)
  • [26] Indoor Air Quality and Bioaerosols in Spanish University Classrooms
    Fuentes-Ferragud, Esther
    Lopez, Antonio
    Piera, Juan Miguel
    Yusa, Vicent
    Garrigues, Salvador
    de la Guardia, Miguel
    Labrador, F. Xavier Lopez
    Camaro, Marisa
    Ibanez, Maria
    Coscolla, Clara
    [J]. TOXICS, 2024, 12 (03)
  • [27] IMPACT OF CO2 CONCENTRATION ON INDOOR AIR QUALITY AND CORRELATION WITH RELATIVE HUMIDITY AND INDOOR AIR TEMPERATURE IN SCHOOL BUILDINGS IN SERBIA
    Lazovic, Ivan M.
    Stevanovic, Zarko M.
    Jovasevic-Stojanovic, Milena V.
    Zivkovic, Marija M.
    Banjac, Milos J.
    [J]. THERMAL SCIENCE, 2016, 20 : S297 - S307
  • [28] Indoor Air Quality in Naturally Ventilated Italian Classrooms
    Fuoco, Fernanda Carmen
    Stabile, Luca
    Buonanno, Giorgio
    Trassiera, Concepcion Vargas
    Massimo, Angelamaria
    Russi, Aldo
    Mazaheri, Mandana
    Morawska, Lidia
    Andrade, Alexandro
    [J]. ATMOSPHERE, 2015, 6 (11) : 1652 - 1675
  • [29] Indoor Air Quality Performance of Ventilation Systems in Classrooms
    Moon, Hyeun Jun
    Sohn, Jong-Ryeul
    Hwang, Taeyon
    [J]. JOURNAL OF ASIAN ARCHITECTURE AND BUILDING ENGINEERING, 2016, 15 (02) : 343 - 348
  • [30] WSN Based Indoor Air Quality Monitoring In Classrooms
    Wang, S. K.
    Chew, S. P.
    Jusoh, M. T.
    Khairunissa, A.
    Leong, K. Y.
    Azid, A. A.
    [J]. 11TH ASIAN CONFERENCE ON CHEMICAL SENSORS (ACCS2015), 2017, 1808