Corrective rescheduling for static voltage stability control

被引:15
|
作者
Arya, LD [1 ]
Sakravdia, DK
Kothari, DP
机构
[1] Shri GS Inst Technol & Sci, Dept Elect Engn, Indore 452003, MP, India
[2] Govt Engn Coll, Dept Elect Engn, Ujjain 456010, Madhya Pradesh, India
[3] Indian Inst Technol, Ctr Energy Studies, New Delhi 110016, India
关键词
load flow Jacobian; Eigen sensitivities; voltage stability; optimization;
D O I
10.1016/j.ijepes.2004.07.005
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes a technique for improving static voltage stability by rescheduling reactive power control variables. The algorithm is based on sensitivities of minimum eigen value with respect to reactive power control variables. Objective function selected is minimization of deviation of squares of reactive power control variables subject to desired increase in minimum eigen value of load flow Jacobian. Since minimum eigen value is system wise voltage stability index increase in load bus voltages as desired is also simultaneously observed. Using Lagrangian optimization technique closed form relations for corrections in reactive power control variables have been obtained. Developed methodology has been implemented on a 6-bus and 25 bus test systems. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3 / 12
页数:10
相关论文
共 50 条
  • [31] Preventive/corrective control for voltage stability using predictor-corrector interior point method
    Guo, RP
    Han, ZX
    Wang, Q
    POWERCON '98: 1998 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY - PROCEEDINGS, VOLS 1 AND 2, 1998, : 1513 - 1517
  • [32] Preventive control approach for voltage stability improvement using voltage stability constrained optimal power flow based on static line voltage stability indices
    Zabaiou, Tarik
    Dessaint, Louis-A
    Kamwa, Innocent
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2014, 8 (05) : 924 - 934
  • [33] OPTIMAL CORRECTIVE RESCHEDULING FOR POWER SYSTEM SECURITY
    KALTENBACH, JC
    HAJDU, LP
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1971, PA90 (02): : 843 - +
  • [34] Sensitivity-based generation rescheduling for multicontingency voltage stability enhancement
    Chakrabarti, Saikat
    Jeyasurya, Benjamin
    2006 POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-9, 2006, : 1912 - +
  • [35] Oscillatory stability limit enhancement by adaptive control rescheduling
    Bijwe, P.R.
    Kelapure, S.M.
    Kothari, D.P.
    Saxena, K.K.
    International Journal of Electrical Power and Energy System, 1999, 21 (07): : 507 - 514
  • [36] Reactive power rescheduling with generator ranking for improving voltage stability margin
    Raoufi, Habibollah
    Kalantar, Mohsen
    2007 LARGE ENGINEERING SYSTEMS CONFERENCE ON POWER ENGINEERING, 2007, : 220 - 227
  • [37] Oscillatory stability limit enhancement by adaptive control rescheduling
    Bijwe, PR
    Kelapure, SM
    Kothari, DP
    Saxena, KK
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 1999, 21 (07) : 507 - 514
  • [38] Risk assessment of static voltage stability
    State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Shapinba Distract, Chongqing 400044, China
    不详
    Zhongguo Dianji Gongcheng Xuebao, 2009, 28 (40-46): : 40 - 46
  • [39] Computation of static voltage stability margin with multiple pilot buses in a control partition
    Yang, Liuqing
    Liu, Mingbo
    Lin, Shunjiang
    Dianwang Jishu/Power System Technology, 2013, 37 (05): : 1346 - 1352
  • [40] A Control Strategy for Static Voltage Stability Based on Air Conditioner Load Regulation
    Li, Dezhi
    Cui, Gaoying
    Sun, Lingling
    Yang, Jiru
    Gao, Ciwei
    Chen, Xiao
    2017 4TH INTERNATIONAL CONFERENCE ON SYSTEMS AND INFORMATICS (ICSAI), 2017, : 288 - 292