Three-dimensional force measurements on oral implants: a methodological study

被引:32
|
作者
Duyck, J
Van Oosterwyck, H
De Cooman, M
Puers, R
Vander Sloten, J
Naert, I
机构
[1] Katholieke Univ Leuven, ESAT MICAS, Dept Prosthet Dent, BIOMAT Res Grp, Louvain, Belgium
[2] Katholieke Univ Leuven, ESAT MICAS, Dept Mech, Div Biomech & Engn Design, Louvain, Belgium
[3] Katholieke Univ Leuven, ESAT MICAS, Dept Electrotech, Louvain, Belgium
来源
JOURNAL OF ORAL REHABILITATION | 2000年 / 27卷 / 09期
关键词
D O I
10.1046/j.1365-2842.2000.00581.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This paper describes a methodology that allows in vitro and in vivo quantification and qualification of forces on oral implants. Strain gauges are adapted to the outer surface of 5.5 and 7 mm standard abutments (Branemark System(R), Nobel Biocare, Sweden). The readings of the strain gauges are transformed into a numerical representation of the normal force and the bending moment around the X- and Y-axis. The hardware and the software of the 3D measuring device based on the strain gauge technology is explained and its accuracy and reliability tested. The accuracy level for axial forces and bending moments is 9.72 N and 2.5 N.cm, respectively, based on the current techniques for strain gauged abutments. As an example, an in vivo force analysis was performed in a patient with a full fixed prosthesis In the mandible. Since axial loads of 450 N and bending moments of 70 N.cm were recorded, it was concluded that the accuracy of the device falls well within the scope of our needs. Nevertheless, more in vivo research is needed before well defined conclusions can be drawn and strategies developed to improve the biomechanics of oral implants.
引用
收藏
页码:744 / 753
页数:10
相关论文
共 50 条
  • [1] Three-dimensional orthodontic force measurements
    Badawi, Hisham
    Major, Paul
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (03) : 299 - 300
  • [2] Three-dimensional orthodontic force measurements
    Badawi, Hisham M.
    Toogood, Roger W.
    Carey, Jason P. R.
    Heo, Giseon
    Major, Paul W.
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (04) : 518 - 528
  • [3] Simultaneous force measurements in 3 dimensions on oral endosseous implants in vitro and in vivo - A methodological study
    MericskeStern, R
    Assal, P
    Buergin, W
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 1996, 7 (04) : 378 - 386
  • [4] Three-dimensional orthodontic force measurements Response
    Turpin, David L.
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (03) : 300 - 300
  • [5] Three-dimensional force measurements with mandibular overdentures connected to implants by ball-shaped retentive anchors. A clinical study
    Mericske-Stern, R
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 1998, 13 (01) : 36 - 43
  • [6] A methodological study on simultaneous force measurements in 3 dimensions on ITI-implants.
    Buergin, W
    MericskeStern, R
    [J]. JOURNAL OF DENTAL RESEARCH, 1996, 75 : 1328 - 1328
  • [8] Microfluidic tactile sensors for three-dimensional contact force measurements
    Nie, Baoqing
    Li, Ruya
    Brandt, James D.
    Pan, Tingrui
    [J]. LAB ON A CHIP, 2014, 14 (22) : 4344 - 4353
  • [9] Elastic Fully Three-dimensional Microstructure Scaffolds for Cell Force Measurements
    Klein, Franziska
    Striebel, Thomas
    Fischer, Joachim
    Jiang, Zhongxiang
    Franz, Clemens M.
    von Freymann, Georg
    Wegener, Martin
    Bastmeyer, Martin
    [J]. ADVANCED MATERIALS, 2010, 22 (08) : 868 - +
  • [10] Three-dimensional force measurements applied by infant during nipple sucking
    Nishi, E.
    Hiraoka, Katsuyuki
    Okuda, Ryosuke
    Niikawa, Takuya
    Rikoh, Katsuhisa
    [J]. 42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 3949 - 3952