Automated detection of shockable and non-shockable arrhythmia using novel wavelet-based ECG features

被引:39
|
作者
Sharma, Manish [1 ]
Singh, Swapnil [2 ]
Kumar, Abhishek [3 ]
Tan, Ru San [4 ]
Acharya, U. Rajendra [5 ,6 ,7 ]
机构
[1] Inst Infrastruct Technol Res & Management, Dept Elect Engn, Ahmadabad, Gujarat, India
[2] Natl Inst Ind Engn, Dept Project Management, Mumbai, Maharashtra, India
[3] Indian Inst Technol, Dept Civil Engn, Madras, Tamil Nadu, India
[4] Natl Heart Care Ctr Singapore, Dept Cardiol, Singapore, Singapore
[5] Ngee Ann Polytech, Dept Elect & Comp Engn, Singapore 599489, Singapore
[6] SUSS, Sch Sci & Technol, Dept Biomed Engn, Singapore, Singapore
[7] Kumamoto Univ, IROAST, Kumamoto, Japan
关键词
Shockable; Heart; ECG; Wavelets; Optimization problem; Machine learning; Semi-definite program; Filter design; Classification; HEART-RATE-VARIABILITY; VENTRICULAR-FIBRILLATION; FILTER BANKS; DIAGNOSIS; SIGNALS; FAILURE; MANAGEMENT;
D O I
10.1016/j.compbiomed.2019.103446
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Malignant arrhythmia can lead to sudden cardiac death (SCD). Shockable arrhythmia can be terminated with device electrical shock therapies. Ventricular-tachycardia (VT) and ventricular fibrillation (VF) are responsive to electrical anti-tachycardia pacing therapy and defibrillation which help to restore normal electrical and mechanical function of the heart. In contrast, non-shockable arrhythmia like asystole and bradycardia are not responsive to electric shock therapy. Distinguishing between shockable and non-shockable arrhythmia is an important diagnostic challenge that has practical clinical relevance. It is difficult to accurately differentiate between these two types of arrhythmia by manual inspection of electrocardiogram (ECG) segments within the short time duration before triggering the device for electrical therapy. Automated defibrillators are equipped with automatic shockable arrhythmia detection algorithms based on ECG morphological features, which may possess variable diagnostic performance depending on machine models. In our work, we have designed a robust system using wavelet decomposition filter banks for extraction of features from the ECG signal and then classifying the features. We believe this method will improve the accuracy of discriminating between shockable and non-shockable arrhythmia compared with existing conventional algorithms. We used a novel three channel orthogonal wavelet filter bank, which extracted features from ECG epochs of duration 2 s to distinguish between shockable and non-shockable arrhythmia. The fuzzy, Renyi and sample entropies are extracted from the various wavelet coefficients and fed to support vector machine (SVM) classifier for automated classification. We have obtained an accuracy of 98.9%, sensitivity and specificity of 99.08% and 97.11.9%, respectively, using 10-fold cross validation. The area under the receiver operating characteristic has been found to be 0.99 with F1-score of 0.994. The system developed is more accurate than the existing algorithms. Hence, the proposed system can be employed in automated defibrillators inside and outside hospitals for emergency revival of patients suffering from SCD. These automated defibrillators can also be implanted inside the human body for automatic detection of potentially fatal shockable arrhythmia and to deliver an appropriate electric shock to the heart.
引用
收藏
页数:10
相关论文
共 50 条
  • [11] Detection of Shockable Ventricular Arrhythmia using Variational Mode Decomposition
    R. K. Tripathy
    L. N. Sharma
    S. Dandapat
    Journal of Medical Systems, 2016, 40
  • [12] Detection of Shockable Ventricular Arrhythmia using Variational Mode Decomposition
    Tripathy, R. K.
    Sharma, L. N.
    Dandapat, S.
    JOURNAL OF MEDICAL SYSTEMS, 2016, 40 (04) : 1 - 13
  • [13] Bystander automated external defibrillator application in non-shockable out-of-hospital cardiac arrest
    Pollack, Ross A.
    Brown, Siobhan P.
    May, Susanne
    Rea, Tom
    Kudenchuk, Peter J.
    Weisfeldt, Myron L.
    RESUSCITATION, 2019, 137 : 168 - 174
  • [14] Comparative assessment of shockable ECG rhythm detection algorithms in automated external defibrillators
    Clifford, AC
    RESUSCITATION, 1996, 32 (03) : 217 - 225
  • [15] Mobile ECG Monitoring System Prorotype and Wavelet-Based Arrhythmia Detection
    Kuzmin, Andrey
    Safronov, Maxim
    Bodin, Oleg
    Prokhorov, Sergey
    Stolbova, Anastasya
    PROCEEDINGS OF THE 2017 21ST CONFERENCE OF OPEN INNOVATIONS ASSOCIATION (FRUCT), 2017, : 210 - 216
  • [16] Subsequent Shockable Rhythm During Out-of-Hospital Cardiac Arrest in Children With Initial Non-Shockable Rhythms: A Nationwide Population-Based Observational Study
    Goto, Yoshikazu
    Funada, Akira
    Goto, Yumiko
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2016, 5 (10):
  • [17] Automated arrhythmia detection using novel hexadecimal local pattern and multilevel wavelet transform with ECG signals
    Tuncer, Turker
    Dogan, Sengul
    Plawiak, Pawel
    Acharya, U. Rajendra
    KNOWLEDGE-BASED SYSTEMS, 2019, 186
  • [18] Detection of Shockable Arrhythmia From Electrocardiogram Signal Using Recurrence Quantification Analysis Based Deep Convolutional Neural Networks
    Mandal, Saurav
    Roy, Anisha Halder
    Mondal, Pulak
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73 : 1 - 1
  • [19] Occurrence of Fibrillation in Out-of-hospital Cardiac Arrest Patients Presenting in a Non-shockable Rhythm when Treated with an Automated External Defibrillator
    Liu, Chenguang
    Gao, Mengqi
    Gehman, Stacy
    Jorgenson, Dawn
    CIRCULATION, 2024, 150
  • [20] Detection of PVC by using a wavelet-based statistical ECG monitoring procedure
    Jung, Yonghan
    Kim, Heeyoung
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2017, 36 : 176 - 182