Predictors of lead break during transvenous lead extraction

被引:15
|
作者
Morita, Junji [1 ]
Yamaji, Kyohei [1 ]
Nagashima, Michio [1 ]
Kondo, Yusuke [2 ]
Sadohara, Yohei [1 ]
Hirokami, Jun [1 ]
Kuji, Rei [1 ]
Korai, Kengo [1 ]
Fukunaga, Masato [1 ]
Hiroshima, Kenichi [1 ]
Ando, Kenji [1 ]
Goya, Masahiko [3 ]
机构
[1] Kokura Mem Hosp, Dept Cardiol, Kitakyushu, Fukuoka, Japan
[2] Chiba Univ, Grad Sch Med, Dept Cardiovasc Med, Chiba, Japan
[3] Tokyo Med & Dent Univ, Dept Cardiovasc Med, Tokyo, Japan
关键词
coradial lead; lead break; pacemaker lead; passive lead; transvenous lead extraction;
D O I
10.1002/joa3.12524
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The incidence, predictors, and clinical impact of lead break during transvenous lead extraction (TLE) were previously unknown. Methods We included consecutive patients who underwent TLE between September 2013 and July 2019 at our institute. Lead break during removal was defined as lead stretching and becoming misshapen, as assessed by fluoroscopy. Results A total of 246 patients underwent TLE for 501 leads. At a patient level, complete success was achieved in 226 patients (91.9%). At a lead level, 481 leads (96.0%) were completely removed and 101 leads (20.1%) were broken during the procedure. Of 392 identified pacemaker leads, 71 (18.3%) were broken during the TLE procedure. A multivariable analysis confirmed high lead age (odds ratio [OR] 1.12, 95% confidence interval (CI) 1.07-1.17; P < .001), passive leads (OR 2.29 95% CI 1.09-4.80; P = .028), coradial leads (OR 3.45 95% CI 1.72-6.92; P < .001), and insulators made of nonpolyurethane (OR 2.38 95% CI 1.03-5.26; P = .04) as predictors of lead break. Broken leads needed longer procedure times and were associated with a higher rate of cardiac tamponade. Conclusions Lead age, coradial bipolar leads, passive leads, and leads without polyurethane insulation were predictors of lead break and could increase the difficulty of lead extraction.
引用
收藏
页码:645 / 652
页数:8
相关论文
共 50 条
  • [21] Hybrid approach for transvenous lead extraction
    Neuzil, P.
    Sediva, L.
    Petru, J.
    Skoda, J.
    Chovanec, M.
    Janotka, M.
    Baroch, J.
    Holdova, K.
    Reddy, V. Y.
    EUROPEAN HEART JOURNAL, 2013, 34 : 594 - 594
  • [22] Looking for lead adhesions while planning for transvenous lead extraction
    Callahan, Thomas D.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (05) : 1041 - 1044
  • [23] OUTCOMES OF TRANSVENOUS LEAD EXTRACTION IN NONAGENARIANS
    Tiwari, Ankur
    Gupta, Ashwani
    Subzposh, Faiz
    McCaffrey, James
    Koman, Eduard
    Saltzman, Heath
    Kutalek, Steven
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (13) : 816 - 816
  • [24] Transvenous lead extraction: to reimplant or not to reimplant?
    Knopp, H.
    Heine, T.
    Lucas, J.
    Doering, M.
    Hindricks, G.
    Richter, S.
    EUROPEAN HEART JOURNAL, 2014, 35 : 691 - 691
  • [25] Predictors of all-cause mortality for patients undergoing transvenous lead extraction
    Azari, A.
    Kristjansdottir, I.
    Gatti, P.
    Gadler, F.
    EUROPEAN HEART JOURNAL, 2022, 43 : 746 - 746
  • [26] Predictors of mortality and outcomes in transvenous lead extraction for systemic and local infection cohorts
    Gould, Justin
    Klis, Magdalena
    Porter, Bradley
    Sidhu, Baldeep S.
    Sieniewicz, Benjamin J.
    Williams, Steven E.
    Teall, Thomas
    Webb, Jessica
    Shetty, Anoop
    Gill, Jaswinder
    Rinaldi, Christopher A.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2019, 42 (01): : 73 - 84
  • [27] Transvenous coronary sinus lead extraction: procedural outcomes and predictors of mechanical dilatation
    Di Cori, A.
    Zucchelli, G.
    Soldati, E.
    Segreti, L.
    De Lucia, R.
    Viani, S.
    Fabiani, I.
    Paperini, L.
    Bongiorni, M. G.
    EUROPEAN HEART JOURNAL, 2011, 32 : 177 - 177
  • [28] Predictors of perforation during lead extraction: Results of the Canadian Lead ExtrAction Risk (CLEAR) study
    Bashir, Jamil
    Lee, Arthur J.
    Philippon, Francois
    Mondesert, Blandine
    Krahn, Andrew D.
    Sadek, Mouhannad M.
    Exner, Derek
    Pak, Melissa
    Legare, Jean Francois
    Karim, Shahzad
    Fedoruk, Lynn
    Peng, Defen
    Cusimano, Robert J.
    Parkash, Ratika
    Tyers, G. Frank O.
    Andrade, Jason
    HEART RHYTHM, 2022, 19 (07) : 1097 - 1103
  • [29] Transvenous Lead Extraction during Cardiac Implantable Device Upgrade: Results from the Multicenter Swiss Lead Extraction Registry
    Haeberlin, Andreas
    Noti, Fabian
    Breitenstein, Alexander
    Auricchio, Angelo
    Reichlin, Tobias
    Conte, Giulio
    Klersy, Catherine
    Curti, Moreno
    Pruvot, Etienne
    Domenichini, Giulia
    Schaer, Beat
    Kuehne, Michael
    Gruszczynski, Michal
    Burri, Haran
    Kobza, Richard
    Grebmer, Christian
    Regoli, Francois D.
    Pelliccia, Francesco
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (16)
  • [30] Cardiac lead management: the future of transvenous lead extraction approaches and technologies
    Segreti, Luca
    Deharo, Jean-Claude
    MINERVA CARDIOANGIOLOGICA, 2018, 66 (01): : 100 - 112