Characteristic Regions of the Fluorescence Excitation-Emission Matrix (EEM) To Identify Hydrophobic/Hydrophilic Contents of Organic Matter in Membrane Bioreactors

被引:66
|
作者
Xiao, Kang [1 ,2 ]
Shen, Yuexiao [3 ]
Liang, Shuai [4 ]
Tan, Jihua [1 ]
Wang, Xiaomao [2 ]
Liang, Peng [2 ]
Huang, Xia [2 ]
机构
[1] Univ Chinese Acad Sci, Coll Resources & Environm, Beijing 100049, Peoples R China
[2] Tsinghua Univ, State Key Joint Lab Environm Simulat & Pollut Con, Sch Environm, Beijing 100084, Peoples R China
[3] Univ Calif Berkeley, Dept Chem, Berkeley, CA 94720 USA
[4] Beijing Forestry Univ, Coll Environm Sci & Engn, Beijing 100083, Peoples R China
基金
中国国家自然科学基金;
关键词
WASTE-WATER TREATMENT; 3-DIMENSIONAL EXCITATION; PREPARATIVE ISOLATION; RAMAN SCATTER; HYDROPHOBICITY; SPECTROSCOPY; INTEGRATION; SUBSTANCES; SPECTRA; PROTEIN;
D O I
10.1021/acs.est.8b02684
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study systematically investigated the correlations between fluorescence distributions characterized by the excitation-emission matrix (EEM) and hydrophobic/hydrophilic composition of dissolved organic matter (DOM) in membrane bioreactors (MBRs). On the basis of samples from 10 full-scale MBRs, we performed point-to-point comparisons among different components using an EEM fluorescence quotient (FQ) method and obtained a hydrophobic/hydrophilic fluorophore distribution map via Wilcoxon signed rank test. Hydrophobic acids/bases (HOA/HOB) concentrated in the low-wavelength region [excitation wave length (Ex) < 235 nm], while hydrophilic substances (HIS) were enriched in the region of Ex > 235 nm [especially with emission wavelength (Em) = 300-360 nm]. Quantitatively, EEM regional contribution to whole wavelength fluorescence was found to significantly correlate with the hydrophobic/hydrophilic proportions of DOM, with Pearson's coefficients of 0.94 and 0.78 (p < 0.01) for HOA and HIS, respectively. We established a linear regression model showing the HOA proportion as a function of the EEM regional contribution at (Ex, Em) = (200-285, 340-465 nm), with R-2 = 0.876, which was validated via leave-one-out cross-validation and Monte Carlo simulation. This study shows a statistically hydrophobicity-dependent fluorescence property across different MBRs, and it might be applied to provide a quick estimation of hydrophobic/hydrophilic composition of DOM in wastewater treatment systems based on EEM monitoring.
引用
收藏
页码:11251 / 11258
页数:8
相关论文
共 50 条
  • [11] Chromophoric dissolved organic matter (CDOM) variability in Barataria Basin using excitation-emission matrix (EEM) fluorescence and parallel factor analysis (PARAFAC)
    Singh, Shatrughan
    D'Sa, Eurico J.
    Swenson, Erick M.
    SCIENCE OF THE TOTAL ENVIRONMENT, 2010, 408 (16) : 3211 - 3222
  • [12] Characterization of organic membrane foulants with front-face fluorescence excitation-emission matrix
    Wu Z.
    Yu H.
    Liang H.
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2019, 51 (02): : 22 - 26
  • [13] Excitation-emission fluorescence matrix to study pH influence on organic matter fluorescence in the Amazon basin rivers
    Patel-Sorrentino, N
    Mounier, S
    Benaim, JY
    WATER RESEARCH, 2002, 36 (10) : 2571 - 2581
  • [14] Characterization of dissolved organic matter (DOM) in landfill leachates using fluorescence excitation-emission matrix
    Le Coupannec, F
    Morin, D
    Sire, O
    Péron, JJ
    ENVIRONMENTAL TECHNOLOGY, 2000, 21 (05) : 515 - 524
  • [15] Assessing the dynamics of chromophoric dissolved organic matter in the southern Yellow Sea by excitation-emission matrix fluorescence and parallel factor analysis (EEM-PARAFAC)
    Bai, Ying
    Su, Rongguo
    Shi, Xiaoyong
    CONTINENTAL SHELF RESEARCH, 2014, 88 : 103 - 116
  • [16] Fluorescence excitation-emission matrix spectra of different sizes of dissolved organic matter produced by microalgae
    Zhao, Weihong
    Wang, Jiangtao
    Cui, Xin
    Ji, Naiyun
    Miao, Hui
    Gaojishu Tongxin/Chinese High Technology Letters, 2007, 17 (01): : 88 - 93
  • [17] Optical Characteristics and Chemical Composition of Dissolved Organic Matter (DOM) from Riparian Soil by Using Excitation-Emission Matrix (EEM) Fluorescence Spectroscopy and Mass Spectrometry
    Wang, Yulai
    Yang, Changming
    Zou, Limin
    Cui, Hengzhao
    APPLIED SPECTROSCOPY, 2015, 69 (05) : 623 - 634
  • [18] Characterization of chromophoric dissolved organic matter (CDOM) in the East China Sea in autumn using excitation-emission matrix (EEM) fluorescence and parallel factor analysis (PARAFAC)
    Ying Bai
    RongGuo Su
    LiHong Yan
    Peng Yao
    XiaoYong Shi
    XiuLin Wang
    Science China Chemistry, 2013, 56 : 1790 - 1799
  • [19] Characterization of urban and industrial wastewaters using excitation-emission matrix (EEM) fluorescence: Searching for specific fingerprints
    Rodriguez-Vidal, Francisco J.
    Garcia-Valverde, Maria
    Ortega-Azabache, Beatriz
    Gonzalez-Martinez, Angela
    Bellido-Fernandez, Ana
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2020, 263
  • [20] Excitation emission matrix (EEM) fluorescence spectral separation and detection of refractory wastewater effluent organic matter (EfOM)
    Wells, Martha J. M.
    Sanez, Juan M.
    Bell, Katherine Y.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 248